TRICONEX 4329

¥2,399.00

The TRICONEX 4329 is a critical 32-Channel Digital Output Module designed for the Triconex Tricon v9, v10, or v11 safety instrumented system (SIS). This module, the TRICONEX 4329, is engineered to provide highly reliable, fault-tolerant output commands from the Triple Modular Redundant (TMR) safety controller to final elements in the field, such as solenoid valves, shutdown valves (SDV), and alarm annunciators. Its primary function is to translate the safety logic’s voted digital decisions into physical, isolated output signals to actuate critical safety devices. The TRICONEX 4329 implements TMR architecture internally, with three independent output circuits per channel that are voted upon at the module’s output terminals, ensuring that no single point of failure can prevent a safe shutdown command. The design of the TRICONEX 4329 is focused on achieving the highest Safety Integrity Level (SIL 3) for emergency shutdown (ESD) and fire and gas (F&G) systems.

Category:

Description

Product Description

The TRICONEX 4329 is a critical 32-Channel Digital Output Module designed for the Triconex Tricon v9, v10, or v11 safety instrumented system (SIS). This module, the TRICONEX 4329, is engineered to provide highly reliable, fault-tolerant output commands from the Triple Modular Redundant (TMR) safety controller to final elements in the field, such as solenoid valves, shutdown valves (SDV), and alarm annunciators. Its primary function is to translate the safety logic’s voted digital decisions into physical, isolated output signals to actuate critical safety devices. The TRICONEX 4329 implements TMR architecture internally, with three independent output circuits per channel that are voted upon at the module’s output terminals, ensuring that no single point of failure can prevent a safe shutdown command. The design of the TRICONEX 4329 is focused on achieving the highest Safety Integrity Level (SIL 3) for emergency shutdown (ESD) and fire and gas (F&G) systems.

Product Parameters

The technical specifications for the TRICONEX 4329 module are defined by its safety-critical role:

  • Module Type: 32-Channel Isolated Digital Output Module.

  • Output Configuration: 32 independent, Form A (solid-state) output channels. Each channel is a single normally-open (NO) solid-state switch.

  • Output Rating: Each channel is rated for a specific voltage and current, typically 30V DC at 0.5A (1A surge). The outputs are designed for DC sinking (positive common) applications.

  • Isolation: Channel-to-channel isolation and isolation between the field side and the internal TMR logic, typically rated at 1500V AC.

  • TMR Architecture: Each of the 32 output points consists of three independent output circuits (one from each main processor). The module performs hardware voting on these three signals to generate the single, final output.

  • Diagnostics: Extensive onboard diagnostics including output verification (readback), circuit continuity monitoring, and module health checks (watchdog, memory). Faults are reported to the main processors.

  • Update Time: Fast output response time suitable for critical safety shutdowns.

  • Power Supply: Requires both +5V logic power from the backplane and a field-supplied output power voltage (typically 24V DC) to power the connected loads.

Advantages and Features

The TRICONEX 4329 provides unparalleled benefits for safety applications:

  • Triple Modular Redundancy (TMR) at the Point: The TRICONEX 4329 implements TMR voting directly at the output point, providing fault tolerance not just in the controller, but all the way to the field connection. This is a defining feature for high-availability safety systems.

  • High-Density Safety Outputs: Provides 32 safety-rated output channels in a single module slot, optimizing cabinet space in large Safety Instrumented Functions (SIFs) with many final elements.

  • Comprehensive Diagnostic Coverage: The module’s advanced diagnostics, including output readback, can detect dangerous failures such as a welded output or an open circuit, fulfilling requirements for high diagnostic coverage in SIL 3 loops.

  • Hot Replacement Capability: In a properly configured system, the 4329 module can be replaced online (hot-swapped) without taking the Tricon system offline, supporting maximum process availability.

  • Certified Safety Integrity: As an integral part of the Tricon system, it is designed and certified for use in SIL 3 applications per IEC 61508 and IEC 61511 standards.

Application Cases in Industry

This module is exclusively used in the most critical safety shutdown systems across hazardous industries:

  • Oil & Gas Production Platforms: Triggers emergency shutdown valves (ESDVs) to isolate wellheads and pipelines upon detection of overpressure, fire, or gas release.

  • Gas Processing and LNG Plants: Initiates shutdown sequences for compressors, turbines, and process trains in the event of hazardous conditions.

  • Petrochemical Refineries: Acts on safety logic to open quench valves, close feed valves, or initiate deluge systems for reactors and fractionation columns.

  • Power Generation (Gas Turbines): Executes the fuel gas safety shutoff valve (SSOV) commands as part of the turbine protection system.

  • Pharmaceutical (Chemical Synthesis): Controls safety interlocks on highly exothermic reactors to initiate emergency cooling or dump sequences.

Comparisons with Competing Products

Compared to standard PLC output modules or even other safety system outputs, the TRICONEX 4329 is in a specialized class:

  • TMR Architecture vs. 1oo1D or 2oo3: The TRICONEX 4329‘s internal TMR voting is fundamentally different from a single channel with diagnostics (1oo1D) or a triple-redundant system that votes in the controller only. It provides a higher level of hardware fault tolerance at the I/O point itself.

  • Integrated Safety System vs. Certified Components: While other systems may use certified relays in conjunction with a PLC, the 4329 is a fully integrated component of a certified system, where the entire path from sensor to logic solver to final element is designed and validated as a cohesive safety loop.

  • Superior Diagnostic Depth: Its output verification (readback) diagnostics are more sophisticated and integral to the safety function than the basic diagnostics found on standard or even most other safety PLC output cards.

  • Proven in Extreme Demands: The Tricon platform and modules like the 4329 have a decades-long, global track record of performance in the world’s most demanding safety applications, which is a key selection criterion for end-users.

Selection Suggestions and Precautions

Selection and handling require strict adherence to safety engineering practices:

  1. System Compatibility: Verify that the TRICONEX 4329 is compatible with your specific Tricon chassis model (v9, v10, v11) and that the backplane and main processors support it.

  2. SIL Verification/Loop Design: The 4329 is a component within a Safety Instrumented Function (SIF). Its use must be part of a full SIL verification calculation (PFDavg calculation) performed by a competent safety engineer to ensure the entire loop meets the target SIL.

  3. Proper Field Wiring and Fusing: Each output must be properly fused according to the Tricon system engineering guidelines. Field wiring must respect the isolation boundaries and use the specified cable types.

  4. Understand the Voting: Recognize that the output is the result of a 2-out-of-3 hardware vote. A single fault in one of the three internal circuits will not affect the output but will be reported as a diagnostic fault.

  5. Authorized Configuration Only: Configuration of the TRICONEX 4329 module (including assignment, naming, and diagnostics enabling) must be done using the approved Triconex TriStation 1131 software and by authorized personnel following strict change management procedures.

1756-L85E PLC
3500/50-041-01-01
8270-1061 PLC
VE4005S2B1 PLC
VE4001S2T284 PLC
Spotron-SP-231N
07AC91
6FC5357-0BB25-0AA0 RC
TKB3100
6ES7516-3AN01-0AB0 PLC

Reviews

There are no reviews yet.

Be the first to review “TRICONEX 4329”

Your email address will not be published. Required fields are marked *

Post comment