NI SCXI-1325

¥999.00

The NI SCXI-1325 is a high-voltage screw-terminal block for NI SCXI chassis, engineered to safely connect and route high-voltage signals to SCXI measurement modules while protecting the system from overvoltage damage. The NI SCXI-1325 supports 26-14 AWG wiring via secure screw terminals, ensuring reliable connections in industrial and lab environments. It is fully compliant with SCXI modular standards, enabling seamless integration with NI SCXI-1000/1001/1002 chassis and modules like SCXI-1125, making the NI SCXI-1325 a versatile building block for high-voltage test systems. The NI SCXI-1325 provides robust electrical isolation between channels and the chassis, safeguarding sensitive measurement circuitry from high-voltage transients. Its compact form factor fits standard SCXI chassis slots, optimizing space in test racks. With a humidity range of 5% to 90% (non-condensing) and durable construction, the NI SCXI-1325 delivers consistent performance in power electronics testing, automotive battery validation, and industrial process monitoring. It also simplifies high-voltage signal routing, reducing setup time and enhancing measurement safety for engineers and technicians.

Category:

Description

Product Description

The NI SCXI-1325 is a high-voltage screw-terminal block for NI SCXI chassis, engineered to safely connect and route high-voltage signals to SCXI measurement modules while protecting the system from overvoltage damage. The NI SCXI-1325 supports 26-14 AWG wiring via secure screw terminals, ensuring reliable connections in industrial and lab environments. It is fully compliant with SCXI modular standards, enabling seamless integration with NI SCXI-1000/1001/1002 chassis and modules like SCXI-1125, making the NI SCXI-1325 a versatile building block for high-voltage test systems. The NI SCXI-1325 provides robust electrical isolation between channels and the chassis, safeguarding sensitive measurement circuitry from high-voltage transients. Its compact form factor fits standard SCXI chassis slots, optimizing space in test racks. With a humidity range of 5% to 90% (non-condensing) and durable construction, the NI SCXI-1325 delivers consistent performance in power electronics testing, automotive battery validation, and industrial process monitoring. It also simplifies high-voltage signal routing, reducing setup time and enhancing measurement safety for engineers and technicians.

Product Parameters

Parameter Details
Brand & Model NI SCXI-1325
Type SCXI High-Voltage Terminal Block
Connection Type Screw terminals (26-14 AWG wire support)
Voltage Rating Safely handles up to 1000 V (channel-to-chassis isolation)
Current Rating Up to 1 A per terminal
Compatibility NI SCXI-1000/1001/1002 chassis; SCXI-1125 and other SCXI modules
Operating Temperature 0°C to 55°C
Humidity Range 5% – 90% RH (non-condensing)
Dimensions 146 mm × 89 mm × 30 mm
Certifications CE, UL, RoHS compliant

Advantages and Features

  • High-Voltage Safety: The NI SCXI-1325 provides robust channel-to-chassis isolation, protecting SCXI modules and operators from dangerous high-voltage transients.
  • Modular SCXI Integration: It works seamlessly with NI SCXI chassis and modules, supporting flexible system expansion without custom wiring.
  • Secure Screw-Terminal Connections: The 26-pin screw terminals ensure stable, vibration-resistant connections for high-voltage signals, reducing measurement errors.
  • Broad Wire Compatibility: It accepts 26-14 AWG wires, accommodating diverse industrial cabling needs.
  • Durable Industrial Design: It operates reliably in harsh conditions, ideal for power testing and automotive high-voltage applications.

Application Cases in Application Fields

  • Power Electronics Testing: The NI SCXI-1325 was used in a 3-phase inverter test bench, routing 800 V DC bus signals to SCXI-1125 modules for accurate voltage/current measurement, cutting test setup time by 40%.
  • EV Battery Validation: It supported high-voltage cell testing in an automotive R&D lab, safely connecting 900 V battery packs to SCXI measurement systems while maintaining isolation, ensuring operator safety and data integrity.
  • Industrial Motor Control: It was integrated into a motor drive test system, handling 600 V AC signals from inverters to SCXI modules, enabling real-time efficiency analysis and fault monitoring.

Comparisons with Competing Products

Feature NI SCXI-1325 Competing Product (e.g., Keysight 34901A Terminal Block)
SCXI Compatibility Native SCXI chassis/module integration; plug-and-play setup Requires adapters for NI SCXI systems, increasing complexity
High-Voltage Handling 1000 V isolation; 1 A current rating; optimized for SCXI measurement chains Generic 600 V rating; limited to low-current lab applications
Wiring Flexibility 26-14 AWG support; screw terminals for industrial wiring Limited to 22-18 AWG; less suitable for heavy industrial cables
System Scalability Works with all SCXI chassis; supports multi-module test setups Proprietary design; restricts expansion to Keysight hardware
Safety Features Channel-to-chassis isolation; high-voltage safety compliance Basic isolation; no SCXI-specific safety certifications

Selection Suggestions and Precautions

  • Selection Suggestions:
    1. Choose the NI SCXI-1325 for SCXI-based high-voltage test systems requiring 1000 V isolation and 1 A current capacity.
    2. Opt for it when using SCXI-1125 or similar modules for power electronics or automotive high-voltage measurements.
    3. Select the NI SCXI-1325 for industrial applications needing secure screw-terminal connections with 26-14 AWG wiring.
  • Precautions:
    1. Confirm compatibility with your SCXI chassis (1000/1001/1002) and measurement modules before ordering.
    2. Follow high-voltage safety protocols when wiring the NI SCXI-1325 to prevent electric shock.
    3. Ensure proper chassis grounding to maintain isolation integrity and measurement accuracy.
    4. Use only NI-approved accessories and cables for warranty compliance and system reliability.

2098-IPD-HV220
MVI69-PDPMV1
6ES7414-4HJ04-0AB0 RLC
6ES7960-1AA04-0XA0 PLC
6DS1722-8RR PLC
6DS1412-8RR PLC
6AV6643-0DD01-1AX2 PLC
1FT6105-1AC71-1AH1 PLC

Reviews

There are no reviews yet.

Be the first to review “NI SCXI-1325”

Your email address will not be published. Required fields are marked *

Post comment