NI SCXI-1141

¥999.00

NI SCXI-1141 is a high-performance simultaneous sampling analog input module developed by National Instruments (NI) for use in their SCXI (Signal Conditioning eXtensions for Instrumentation) platform. This module is a critical component for creating flexible and scalable data acquisition systems in various industries, research laboratories, and test facilities.

The NI SCXI-1141 is designed to simultaneously sample multiple analog input channels, which is essential for applications where the phase relationship between signals must be preserved. It features programmable lowpass filtering for each channel, making it ideal for anti-aliasing and noise reduction in high-precision measurements. The module installs in a SCXI chassis and provides high accuracy, low noise, and channel-to-channel isolation. For facilities and research centers using NI equipment for tasks like vibration analysis, sound and vibration testing, and multi-channel transient recording, having a functional, genuine module like the NI SCXI-1141 is absolutely critical for obtaining accurate and reliable measurement data. When maintaining your measurement system, sourcing a genuine NI SCXI-1141 【insert link here】 is key to a seamless replacement.

Category:

Description

NI SCXI-1141 Product Overview

NI SCXI-1141 is a high-performance simultaneous sampling analog input module developed by National Instruments (NI) for use in their SCXI (Signal Conditioning eXtensions for Instrumentation) platform. This module is a critical component for creating flexible and scalable data acquisition systems in various industries, research laboratories, and test facilities.

The NI SCXI-1141 is designed to simultaneously sample multiple analog input channels, which is essential for applications where the phase relationship between signals must be preserved. It features programmable lowpass filtering for each channel, making it ideal for anti-aliasing and noise reduction in high-precision measurements. The module installs in a SCXI chassis and provides high accuracy, low noise, and channel-to-channel isolation. For facilities and research centers using NI equipment for tasks like vibration analysis, sound and vibration testing, and multi-channel transient recording, having a functional, genuine module like the NI SCXI-1141 is absolutely critical for obtaining accurate and reliable measurement data. When maintaining your measurement system, sourcing a genuine NI SCXI-1141 【insert link here】 is key to a seamless replacement.

Technical Parameters and Specifications

The technical specifications of the NI SCXI-1141 meet National Instruments’ high standards for precision measurement systems:

  • Physical Characteristics: Housed in the standard modular format for SCXI systems, it is designed for installation in a SCXI chassis (e.g., SCXI-1000, SCXI-1001). It features a robust, shielded metal enclosure that provides excellent electromagnetic interference protection. The front panel contains a 50-pin connector for field signal wiring.

  • Channel Configuration: The NI SCXI-1141 typically provides 8 differential analog input channels, all capable of simultaneous sampling.

  • Simultaneous Sampling: This is the key feature of the SCXI-1141. It uses a dedicated analog-to-digital converter (ADC) per channel or a simultaneous sample-and-hold circuit for all channels, ensuring that the signals on all inputs are captured at precisely the same moment. This preserves the phase relationship between channels, which is critical for applications like power measurement, vibration analysis, and acoustic location.

  • Programmable Lowpass Filtering: Each channel includes a programmable 4-pole Butterworth lowpass filter. The cutoff frequency can be configured via software, allowing users to tailor the filter to their specific signal bandwidth and reject out-of-band noise and prevent aliasing.

  • Input Ranges and Gain: The module offers multiple software-selectable input voltage ranges, allowing it to accommodate signals of different amplitudes. It also has programmable gain amplifiers to optimize the signal level for the ADC.

  • Accuracy and Resolution: Provides high measurement accuracy and low noise, making it suitable for demanding measurement applications.

  • Compatibility: The NI SCXI-1141 is compatible with a wide range of NI DAQ (Data Acquisition) cards connected through the SCXI chassis, and it is fully supported by NI’s software platforms like LabVIEW and LabWindows/CVI.

Key Advantages and Features

  1. Simultaneous Sampling for Phase Integrity: The most significant advantage of the NI SCXI-1141 is its ability to capture all input channels simultaneously. This preserves the phase relationships between signals, which is absolutely essential for applications like power quality analysis (measuring voltage and current simultaneously), modal analysis in structural testing, and acoustic beamforming. The NI SCXI-1141 excels where timing matters.

  2. Programmable Anti-Aliasing Filters: The integrated programmable lowpass filters on each channel are crucial for high-accuracy measurements. They allow users to eliminate high-frequency noise and prevent aliasing, ensuring that the digitized signal accurately represents the original analog waveform without distortion.

  3. Seamless Integration with NI Ecosystem: The module integrates perfectly with NI’s hardware and software, including LabVIEW. This provides easy configuration, automatic channel calibration, and access to powerful analysis and visualization tools. Ordering an NI SCXI-1141 【insert link here】 ensures you receive a component with guaranteed compatibility.

  4. High Channel Density: Providing 8 simultaneous sampling channels in a single SCXI slot offers a good balance of channel count and density, allowing users to build multi-channel systems without requiring an excessive number of modules.

  5. Excellent Signal Conditioning: The combination of programmable gain and filtering provides comprehensive signal conditioning in a single module, simplifying system design and improving measurement accuracy.

Application Cases and Industry Use

  • Vibration and Structural Testing: In aerospace or automotive testing, multiple NI SCXI-1141 modules can be used to simultaneously acquire data from a large array of accelerometers mounted on a structure (e.g., an aircraft wing or car body) during modal analysis or shaker table testing.

  • Power Quality Monitoring: For analyzing power consumption and power quality in industrial facilities, the SCXI-1141 can simultaneously sample voltage and current signals from multiple phases, allowing for accurate calculation of real, reactive, and apparent power, as well as harmonic analysis.

  • Acoustics and Noise Control: In acoustic beamforming or noise source localization, multiple microphones are sampled simultaneously. The NI SCXI-1141 is ideal for this, preserving the phase information needed to determine the direction and location of sound sources.

  • Transient Recording: In scientific experiments or power system analysis, capturing fast, transient events accurately requires simultaneous sampling of multiple channels to understand the event’s impact on different parts of a system.

  • Multi-Axis Control Systems: In research or advanced manufacturing, simultaneous feedback from multiple sensors (e.g., position, force, torque) is needed for precise multi-axis control algorithms.

Comparison with Competiting Products

In the field of modular signal conditioning and simultaneous sampling, the NI SCXI-1141 has competitors, but the NI ecosystem is unique.

  • Compared to Similar Modules from Other DAQ Vendors (e.g., Keysight, Data Translation): Other vendors offer simultaneous sampling modules. The NI SCXI-1141 benefits from deep integration with LabVIEW, which is a de facto standard in many test and measurement applications.

  • Compared to PXI-Based Simultaneous Sampling Modules: PXI offers higher bandwidth and density. However, SCXI is often preferred for applications requiring high channel counts with excellent signal conditioning at a potentially lower cost per channel. The SCXI-1141 remains a strong choice for medium-speed, high-channel-count simultaneous sampling.

  • Compared to Standard Multiplexed SCXI Modules: Standard SCXI analog input modules (like SCXI-1100) scan channels sequentially. This breaks the phase relationship. The NI SCXI-1141 is the correct choice for applications where preserving phase is critical, whereas a multiplexed module is suitable for general-purpose data logging where timing between channels is less important.

Selection Suggestions and Precautions

  1. Precise Model Identification: Before ordering an NI SCXI-1141, verify the full part number against the markings on your existing module or the system documentation. Ensure it is the exact model required for your application. Use the exact part number when inquiring with your supplier via the provided link 【insert link here】.

  2. Verify Chassis Compatibility: Confirm that the SCXI-1141 is compatible with your SCXI chassis model.

  3. Consider Channel Count and Sampling Rate: Ensure that the number of channels (8) and the maximum sampling rate meet the requirements of your application. For higher channel counts, multiple SCXI-1141 modules can be used.

  4. Check Software Support: Confirm that the SCXI-1141 is supported by your version of NI-DAQmx and your development environment (e.g., LabVIEW version).

  5. Choose a Reputable Supplier: To guarantee authenticity and quality, purchase your NI SCXI-1141 only from authorized National Instruments distributors or from well-established, reputable companies specializing in measurement and automation spare parts. Sourcing through a trusted channel like the one at your link ensures you receive a genuine product with reliable performance.

3HAC7998-1 PLC
3HNE06223-1 PLC
ABB DSQC664 PLC
ABB 3HAC12158-1 PLC

Reviews

There are no reviews yet.

Be the first to review “NI SCXI-1141”

Your email address will not be published. Required fields are marked *

Post comment