Description
Key Specifications
| Parameter | Specification |
|---|---|
| Serial Ports | 8 configurable serial ports (RS-232, RS-422, RS-485) — increased from 6 |
| Serial Data Rate | Up to 115.2 kbps (standard), 2 Mbps (high-speed mode) — improved |
| Serial Protocols | Modbus RTU, DNP3, ASCII, GE Serial, Profibus DP, IEC 60870-5-101, IEC 60870-5-104 (new) |
| Ethernet Bridge | 2 Ethernet ports (10/100/1000Base-T) |
| Protocol Conversion | Serial-to-Ethernet, Ethernet-to-Serial, Multi-protocol gateway |
| Data Buffering | 4 MB buffer for serial data queuing (expanded) |
| Security Features | Firewall, IP filtering, encrypted communication (TLS) , secure boot (new) |
| Diagnostics | 1000-event fault log with timestamps, communication statistics, and packet capture (expanded) |
| Isolation | 1500 VDC (serial-to-backplane) |
| Form Factor | 6U VME64x (160 × 233 mm), single-slot width |
| Operating Temp | 0 °C to +60 °C |
| Power Draw | 14 W (+5 V / +3.3 VDC) |
| Connectors | Front-panel DB9 serial ports + RJ45 Ethernet ports |
Advantages & Distinctive Features
-
8 Serial Ports: Supports up to 8 legacy serial devices per module.
-
Flexible Serial Configuration: RS-232, RS-422, or RS-485 per port.
-
Expanded Protocol Support: Added IEC 60870-5-104 for power utility communication over TCP/IP.
-
Larger Data Buffer: 4 MB buffer for high-throughput applications.
-
Integrated Security: Firewall, IP filtering, TLS encryption, and secure boot for cyber protection.
-
Protocol Conversion: Converts between serial and Ethernet protocols.
-
High-Speed Mode: 2 Mbps for high-speed serial devices.
-
Redundant Ethernet Ports: Two ports for network redundancy.
-
Expanded Diagnostic Log: 1000-event fault log with communication statistics and packet capture.
-
Hot-Swappable: No rack power-down for replacement.
-
Direct Retrofit: Replaces older ISBB series boards.
Application Fields
-
Legacy Device Integration: Connecting serial devices to Mark VIe
-
Modbus RTU Networks: SCADA and DCS integration
-
DNP3 Networks: Utility substation communication
-
IEC 60870-5-101/104: Power utility communication
-
Profibus DP: Third-party device integration
-
Plant Communication: Serial-to-Ethernet bridging with security
-
Cyber-Secure Communication: TLS encrypted serial-to-Ethernet
Comparison with ISBBH2A and Competitors
| Feature | GE IS215ISBBH3A | GE IS215ISBBH2A | Competitor A | Competitor B |
|---|---|---|---|---|
| Serial Ports | 8 | 6 | 4 | 8 |
| Data Rate | 115.2 kbps (2 Mbps) | 115.2 kbps (1 Mbps) | 115.2 kbps | 115.2 kbps (1 Mbps) |
| Protocols | Modbus RTU, DNP3, ASCII, Profibus DP, IEC 60870-5-101/104 | Modbus RTU, DNP3, ASCII, Profibus DP, IEC 60870-5-101 | Modbus RTU, DNP3 | Modbus RTU, DNP3, IEC 60870-5-104 |
| Data Buffer | 4 MB | 2 MB | 512 KB | 4 MB |
| Security Features | Firewall, IP filtering, TLS, secure boot | None | None | Basic |
| Packet Capture | Yes | No | No | No |
| Fault Logging | 1000 events | 750 events | No | 500 events |
| Hot-Swappable | Yes | Yes | No | Yes |
Selection Guidelines
-
When to choose: Applications requiring high-density serial integration with expanded protocol support, high-speed communication, and cybersecurity features.
-
Serial Configuration: Configure port type, baud rate, parity, and protocol per port.
-
Protocol Conversion: Configure serial-to-Ethernet mapping in Toolbox ST.
-
High-Speed Mode: Enable for devices requiring >115.2 kbps (up to 2 Mbps).
-
Security Configuration: Configure firewall, IP filtering, and TLS encryption.
-
IEC 60870-5-104: Configure for power utility communication over TCP/IP.
-
Compatibility: Fits all Mark VIe VME64x racks. Requires ControlST v7.0 or higher.
Operational Precautions
-
Wiring: Follow GE wiring diagrams—correct polarity for RS-232/422/485.
-
Serial Configuration: Verify baud rate, parity, and stop bits match connected devices.
-
Security Configuration: Configure firewall and encryption before network connection.
-
Protocol Testing: Test each serial port during commissioning.
-
Ethernet Configuration: Configure IP addresses before plant network connection.
-
LED Diagnostics: Green = normal; Amber = communication active; Red = fault.
-
Fault Log: Access 1000-event log via Toolbox ST—packet capture included.
-
Hot-Swap: Remove/insert slowly under power.
-
Spare Stock: Maintain 1 spare per 3–4 racks.
-
Firmware Updates: Ensure the GE IS215ISBBH3A is in “standby” mode during updates.
-
ESD: Handle by edges with grounded wrist strap.

A-B 1769-IF16C
A-B 1764-28BXB
A-B 1794-IT8


Reviews