Key Specifications
| Parameter | Specification |
|---|---|
| Bridge Sensor Inputs | 8 dedicated bridge sensor inputs (strain gauges, pressure transducers, load cells) |
| Bridge Excitation | Programmable (0.5 V, 1 V, 2.5 V, 5 V, 10 V) |
| Bridge Sensor Resolution | 24-bit ADC |
| Bridge Sensor Accuracy | ±0.02% of full scale (improved over H2B) |
| Pressure Inputs | 8 differential analog inputs (4–20 mA, 0–10 V) |
| Pressure Input Accuracy | ±0.03% of full scale (improved over H2B) |
| Pulse/Frequency Inputs | 4 high-speed pulse/frequency input channels |
| Pulse Input Range | 0.5 Hz to 100 kHz |
| Pulse Accuracy | ±0.003% of reading (improved over H2B) |
| Protection Functions | Over-pressure trip, over-speed trip, rate-of-change detection, 2-out-of-3 voting logic |
| Response Time | <3 ms for protection logic (improved over H2B) |
| Isolation | 1500 VDC (I/O-to-backplane) |
| Diagnostics | 1000-event fault log with timestamps and waveform snapshots (expanded) |
| Operating Temp | –30 °C to +75 °C (extended range) |
| Humidity | 5–100% condensing (silicone coating standard) |
| Coating | Silicone conformal coating + enhanced edge encapsulation (UV-traceable) |
| Manufacturing | 120-hour burn-in, 100% X-Ray/AOI, military-grade components |
| Form Factor | 6U VME64x (160 × 233 mm), single-slot width |
| Power | 16 W (+5 V / +3.3 VDC) |
| Connectors | 48-pin terminal block with gold-plated contacts and captive washer screws |
Advantages & Distinctive Features
-
Fastest Protection Response: <3 ms trip detection—meets the most stringent API 670 requirements.
-
Improved Accuracy: ±0.02% bridge accuracy and ±0.003% pulse accuracy.
-
Expanded Diagnostic Log: 1000-event fault log with waveform snapshots.
-
Silicone Conformal Coating + Edge Encapsulation: Superior protection against humidity, salt spray, chemicals, and condensing environments.
-
Widest Temperature Range: –30 °C to +75 °C.
-
Condensing Humidity Rating: 5–100% condensing—suitable for offshore and unheated installations.
-
Military-Grade Manufacturing: 120-hour burn-in, 100% X-ray/AOI, military-grade components.
-
Gold-Plated Captive Washer Terminals: Corrosion-resistant and vibration-proof.
-
Hot-Swappable: No rack power-down for replacement.
-
Direct Retrofit: Replaces all BPPB and BAPA series boards.
Application Fields
-
Boiler Protection: Pressure monitoring, drum level, over-pressure trip
-
Gas Turbines: Speed measurement, pressure monitoring, overspeed protection
-
Steam Turbines: Speed measurement, pressure monitoring, overspeed protection
-
Compressors: Surge detection, speed monitoring, pressure monitoring
-
Safety Systems: 2-out-of-3 voting for critical trips
-
Offshore platforms: Salt-spray and condensing environments
-
Nuclear Power Plants: Safety-critical protection with highest reliability
Comparison with BPPBH2B and Competitors
| Feature | GE IS210BPPBH2BMD | GE IS210BPPBH2B | Competitor A | Competitor B |
|---|---|---|---|---|
| Bridge Inputs | 8 | 8 | None | 4 |
| Pressure Inputs | 8 | 8 | 8 | 8 |
| Pulse Inputs | 4 (100 kHz) | 4 (100 kHz) | None | 2 (50 kHz) |
| Response Time | <3 ms | <5 ms | <10 ms | <10 ms |
| Accuracy (bridge) | ±0.02% | ±0.03% | N/A | ±0.05% |
| Coating Type | Silicone + edge | None | Optional | Optional |
| Temp Range | –30 to +75 °C | 0 to +60 °C | 0 to +55 °C | –10 to +55 °C |
| Humidity | 5–100% condensing | 5–95% non-condensing | 5–90% | 5–95% |
| Fault Logging | 1000 events | 750 events | No | No |
Selection Guidelines
-
When to choose:
-
Critical boiler and turbine protection requiring <3 ms response
-
Extreme environments (–30 to +75 °C, condensing, salt spray, chemical exposure)
-
Applications needing the highest accuracy and expanded diagnostics
-
Maximum reliability (nuclear, critical infrastructure)
-
-
When to choose “H2B” instead: For less extreme environments (0–60 °C, non-condensing) where silicone coating is not required.
-
Bridge Configuration: Configure excitation voltage per manufacturer specifications.
-
Protection Logic: Configure trip setpoints and 2-out-of-3 voting logic in Toolbox ST.
-
Coating Verification: Inspect under UV (365 nm)—silicone coating shows distinct fluorescence; verify edge encapsulation bead is continuous.
-
Compatibility: Fits all Mark VIe VME64x racks. Requires ControlST v6.5 or higher.
Operational Precautions
-
Wiring: Follow GE wiring diagrams—correct polarity and shield grounding essential.
-
Bridge Excitation: Verify excitation voltage does not exceed sensor manufacturer specifications.
-
Protection Testing: Simulate over-pressure and over-speed conditions to verify <3 ms trip response.
-
Voting Logic Testing: Simulate single-channel failures to verify 2-out-of-3 logic.
-
Calibration: Factory calibrated—verify against known references during commissioning.
-
LED Diagnostics: Green = normal; Amber = alert; Red = trip/fault.
-
Fault Log: Access 1000-event log via Toolbox ST—review waveform snapshots.
-
Coating Care: Use GE-approved silicone-safe cleaner; inspect annually under UV—rework voids with approved silicone coating per GE FSB-MKVIe-112.
-
Hot-Swap: Remove/insert slowly under power.
-
Spare Stock: Maintain 1 spare per 3–4 racks; “H2BMD” backward-compatible with all BPPB sockets.
-
Firmware Updates: Ensure the GE IS210BPPBH2BMD is in “standby” mode during updates.
-
ESD: Handle by edges with grounded wrist strap—coating does not protect connectors.
-
Storage: Anti-static bag with desiccant at –40 to +85 °C; rotate every 3 years for coating inspection.

A-B SK-R9-PCG1-FF7
SCHNEIDER 140CPS11420
YASKAWA SGDV-1R6A11B002000