IS200WROBH1A GE

¥999.00

The GE IS200WROBH1A is a VMEbus terminal board manufactured by General Electric for the Mark VIe distributed control system (DCS). This board is a dedicated Relay Output Module, designed to provide high-current, isolated relay outputs for controlling field devices such as solenoids, contactors, motor starters, and alarm annunciators. The GE IS200WROBH1A converts digital control signals from the processor board (VPRO series) into robust relay contact outputs, enabling reliable switching of AC and DC loads in turbine control applications. The “H1A” designation indicates a first-generation relay output module with robust isolation and protection features.

Category:

Description

Key Specifications

Parameter Specification
Output Channels 16 Form A (normally open) relay outputs
Contact Rating 5 A @ 250 VAC / 30 VDC (resistive load)
Inrush Capability 10 A for 100 ms (inductive/capacitive loads)
Coil Voltage 24 VDC nominal (module powered)
Switching Frequency Maximum 10 Hz (mechanical life limitation)
Mechanical Life >10,000,000 operations (no load)
Electrical Life >100,000 operations at rated load
Protection Built-in flyback diodes (for DC inductive loads), snubber circuits (for AC loads — optional external)
Diagnostic Feedback Output state feedback (verifies relay contact closure via auxiliary contact)
Isolation 1500 VDC (coil-to-contacts), 1000 VDC (contact-to-contact)
Communication I/O Net (dual Ethernet ports for redundancy)
Form Factor 6U VME64x (160 × 233 mm), single-slot width
Indicators Per-channel LED (output state/command), module health, communication status
Operating Temp 0 °C to +60 °C
Power Draw 8 W (+5 V / +3.3 VDC) — coil power derived from backplane
Connectors Front-panel 32-pin terminal block with captive washer screws
Diagnostic Memory Non-volatile fault logging — stores last 500 events with timestamps

Advantages & Distinctive Features

  • High-Capacity Relay Outputs: 16 individually isolated Form A relays with 5 A contact rating—controls a wide range of field devices directly.

  • High Inrush Capability: 10 A for 100 ms handles solenoid and motor starting surges.

  • Contact Status Feedback: Each relay includes an auxiliary contact for output state verification—ensures the processor knows the actual contact position.

  • Output State Feedback: Provides actual relay state to the processor for sequence verification and diagnostics.

  • Built-in Flyback Diodes: Protects the module and backplane from voltage spikes when switching DC inductive loads.

  • Long Mechanical Life: 10 million operations at no load—suitable for frequently cycled valves and actuators.

  • Captive Washer Terminals: Prevents screw loosening due to vibration.

  • Hot-Swappable: Supports removal and replacement without powering down the rack.

  • Direct Retrofit: Replaces older WROB series boards.


Application Fields

  • Gas Turbines: Solenoid control, motor starters, valve actuation, alarm annunciation

  • Steam Turbines: Trip solenoid control, motor starters, drain valve control

  • Compressors: Motor starters, solenoid control, surge control valves

  • Generators: Alarm annunciation, motor starters, synchronizing control

  • Balance of Plant: Pump control, fan starters, filter differential pressure alarms

  • Marine: Motor starters, solenoid valves, alarm systems


Comparison with Competing Products

Feature GE IS200WROBH1A Competitor A (Siemens SM 322) Competitor B (Rockwell 1794-OW8)
Output Channels 16 8 8
Contact Rating 5 A @ 250 VAC / 30 VDC 2 A 2 A
Inrush Capability 10 A (100 ms) No No
Contact Status Feedback Yes No No
Inductive Load Protection Built-in flyback diodes External required External required
Isolation 1500 VDC 1500 VDC 1500 VDC
Fault Logging 500 events No No
Hot-Swappable Yes No Yes

The GE IS200WROBH1A offers superior channel density, contact rating, inrush capability, and status feedback—making it the ideal solution for demanding relay output applications.


Selection Guidelines

  • When to choose: Any Mark VIe application requiring high-current relay outputs—solenoids, motor starters, contactors, alarms.

  • Load Verification: Verify each load ≤5 A continuous; ≤10 A inrush. For AC inductive loads, install external snubbers across contacts.

  • Output Configuration: Use Toolbox ST to configure relay behavior (normally de-energized or energized).

  • Contact Status Feedback: Enables verification of actual contact closure—recommended for safety-critical applications.

  • Wiring: Use appropriate wire gauge (14–18 AWG) for load currents; use shielded cables for long runs.

  • Compatibility: Fits all Mark VIe VME64x racks. Requires ControlST v6.0 or higher.


Operational Precautions

  1. Wiring: Follow GE wiring diagrams—correct polarity for DC loads. Use external snubbers for AC inductive loads to extend contact life.

  2. Load Testing: Test each output with actual load during commissioning—verify contact status feedback matches command.

  3. Contact Life: Relay contacts have finite electrical life—monitor switching frequency and cycle counts in Toolbox ST.

  4. Inrush Current: Ensure inrush current does not exceed 10 A per channel—excessive inrush can weld contacts.

  5. LED Diagnostics: Green = commanded ON; Amber = commanded OFF; Red = fault. Refer to GEH-6910 for blink codes.

  6. Fault Log: Access 500-event log via Toolbox ST for post-event analysis.

  7. Hot-Swap: Remove/insert slowly under power—processor auto-recognizes new module.

  8. Spare Stock: Maintain 1 spare per 3–4 racks.

  9. Annual Verification: Cycle relays during outages; verify switching times and contact resistance.

  10. Firmware Updates: Ensure the GE IS200WROBH1A is in “standby” mode during updates.

  11. ESD: Handle by edges only with grounded wrist strap.

GE IC693ALG221J
Siemens 6EP1336-3BA00-8AA0
A-B 1746-NI8
A-B 1756-0F8

Reviews

There are no reviews yet.

Be the first to review “IS200WROBH1A GE”

Your email address will not be published. Required fields are marked *

Post comment