IS200TTURH1BAA GE

¥999.00

IS200TTURH1BAA is an advanced Terminal Board within the GE Mark VIe Speedtronic control system, designed as a high-density field termination and signal conditioning interface for thermocouple and universal analog inputs with extended channel capacity, enhanced diagnostics, extended temperature range, and comprehensive calibration management. This board provides centralized termination for thermocouple sensors (J, K, T, E, R, S, B) as well as 4–20 mA, RTD, or voltage signals, combining multiple sensor types in a single board. The IS200TTURH1BAA features integrated termination points with built-in signal conditioning including dual cold-junction compensation (CJC) for thermocouples, excitation for RTDs, filtering, enhanced isolation, and diagnostics. It offers 24 universal input channels—a 50% increase over IS200TTURH1B (16 channels)—with the highest accuracy, advanced diagnostics, and comprehensive calibration management.

Category:

Description

Product Parameters

Parameter Specification
Brand / Series GE Mark VIe Speedtronic
Model IS200TTURH1BAA
Total Channels 24 universal inputs (configurable per channel) — upgraded from 16 channels
Thermocouple Inputs Up to 24 channels (J, K, T, E, R, S, B)
RTD Inputs Up to 24 channels (Pt100, Ni120, 3-wire or 4-wire)
Analog Transducer Inputs Up to 24 channels (4–20 mA, 0–10 V, ±10 V selectable)
Thermocouple Range ±100 mV
RTD Range 0–400 Ω (Pt100: –200°C to +850°C; Ni120: –60°C to +250°C)
Transducer Range 0–20 mA, 4–20 mA, 0–5 V, 0–10 V, ±10 V
RTD Excitation Programmable 0.5/1.0/2.0 mA
Cold-Junction Compensation Dual redundant CJC sensors (accuracy ±0.2°C)
ADC Resolution 24-bit delta-sigma (thermocouple/RTD), 16-bit SAR (transducer)
Sampling Rate 2–250 SPS (thermocouple/RTD), 10–500 SPS (transducer)
Accuracy (TC) ±0.03% of reading + ±0.3°C
Accuracy (RTD) ±0.03% of reading + ±0.15°C
Accuracy (Transducer) ±0.03% FS
Lead-Wire Compensation Automatic (3-wire and 4-wire RTD) with advanced imbalance correction
Transducer Loop Power 24 VDC (externally supplied only)
Isolation 2000 VAC (field-to-system)
CMRR >110 dB @ 50/60 Hz
Diagnostics Open-circuit detection, short-circuit detection, dual CJC fault monitoring and auto-failover, lead-wire imbalance monitoring and correction, over/under-range detection, loop power fault monitoring, reference validation, calibration status tracking, sensor drift detection
Status Indication 24 green LEDs (channel active), 2 red LEDs (diagnostic fault summary), 1 yellow LED (reference/calibration status), 1 blue LED (CJC redundancy active)
Calibration Features Onboard calibration memory with traceable records, software-triggered self-calibration, factory calibration certificate stored onboard
Operating Temperature –40°C to +70°C
Storage Temperature –55°C to +85°C
Mounting VME rack-mount terminal board with front-panel I/O connectors
Backplane Interface VME64x (A24/A32, D16/D32/D64)
EMC Compliance IEC 61000-4 Level 4

Advantages & Key Features

  • Extended Channel Capacity: 24 universal inputs in a single VME slot—50% more channels than IS200TTURH1B (16 channels), double the density of competing universal modules. Ideal for large turbine systems with diverse sensor monitoring requirements.

  • Universal Input Flexibility: Combines thermocouple, RTD, and transducer inputs on a single board.

  • Configurable Channel Allocation: Each channel independently configurable via GE ToolboxST.

  • Highest Accuracy: TC: ±0.03% + ±0.3°C; RTD: ±0.03% + ±0.15°C; Transducer: ±0.03% FS.

  • Dual-Redundant CJC: Two independent CJC sensors with automatic failover.

  • Advanced Lead-Wire Compensation: Automatic compensation with advanced imbalance correction.

  • Extended Temperature Range: –40°C to +70°C operation makes IS200TTURH1BAA suitable for extreme environments.

  • Enhanced Isolation: 2000 VAC isolation and >110 dB CMRR provide superior protection.

  • Sensor Drift Detection: Tracks sensor performance over time to predict failures.

  • Advanced Calibration: Onboard calibration memory with traceable records, factory certificate, and software-triggered self-calibration.

  • Comprehensive Diagnostics: Open-circuit, short-circuit, dual CJC auto-failover, lead-wire imbalance monitoring and correction, over/under-range, loop power fault, reference validation, calibration status, and sensor drift detection.

  • High-Density Status Indication: 24 green LEDs enable rapid on-site channel status identification.

  • ToolboxST Integration: Full configuration, calibration, and diagnostics via GE ToolboxST.

  • Drop-In Replacement: Direct replacement for IS200TTURH1BIS200TTURH1A, and earlier universal input terminal boards.

Application Fields

  • Gas & Steam Turbines (GE Frame 6B/7EA/9E/HA): Exhaust gas temperature (thermocouple), bearing temperature (RTD), fuel gas pressure (4–20 mA), steam pressure (4–20 mA), valve position feedback (0–10 V), and additional monitoring points for large turbine systems.

  • Combined Cycle Plants: HRSG superheater temperature (thermocouple), feedwater temperature (RTD), steam drum pressure (4–20 mA), and flow (4–20 mA).

  • Compressor Stations: Discharge temperature (thermocouple), bearing temperature (RTD), and suction/discharge pressure (4–20 mA).

  • Nuclear Power Plants: Critical monitoring with documented calibration and maximum precision.

  • Arctic & Desert Installations: Extreme-environment monitoring applications.

  • Offshore Platforms: Marine enclosures with salt-spray and wide temperature swings.

Comparison with Competing Products

Feature GE IS200TTURH1BAA GE IS200TTURH1B (16-ch) GE IS200TTURH1A (16-ch) Competitor A (Universal Input) Competitor B (Separate Modules)
Total Inputs 24 universal 16 universal 16 universal 8 universal 16 (4+4+8)
CJC Accuracy ±0.2°C (dual) ±0.2°C (dual) ±0.5°C (single) ±1.2°C ±0.5°C
TC Accuracy ±0.03% + ±0.3°C ±0.03% + ±0.3°C ±0.1% + ±1°C ±0.2% + ±2°C ±0.1% + ±1°C
RTD Accuracy ±0.03% + ±0.15°C ±0.03% + ±0.15°C ±0.1% + ±0.3°C ±0.1% + ±0.3°C
Transducer Accuracy ±0.03% FS ±0.03% FS ±0.1% FS ±0.2% FS ±0.1% FS
Isolation 2000 VAC 2000 VAC 1500 VAC 1000 VAC 1500 VAC
Operating Temp –40°C to +70°C –40°C to +70°C –30°C to +65°C 0°C to 50°C –30°C to +65°C
Calibration Records Yes (traceable + certificate) Yes No No No
Sensor Drift Detection Yes Yes No No No

Key AdvantageIS200TTURH1BAA delivers 24 universal inputs—50% more channels than IS200TTURH1B, double the density of competing universal modules—with dual-redundant CJC (±0.2°C), the highest accuracy, extended –40°C to +70°C temperature range, 2000 VAC isolation, comprehensive diagnostics including sensor drift detection, and advanced calibration management with traceable records and factory certificates—making it the premier solution for large turbine systems requiring maximum-density, highest-precision universal sensor monitoring with documented calibration in extreme environments.

Selection Guidelines & Recommendations

  • Channel Configuration: Determine required mix—configure each channel in GE ToolboxST.

  • Input Type: Select thermocouple type, RTD type, or transducer type per channel.

  • Dual CJC Sensors: Automatic failover—blue LED indicates redundancy is active.

  • RTD Excitation: Use 0.5 mA for small sensors or 2.0 mA for long cable runs.

  • RTD Wiring: Configure 3-wire or 4-wire per channel.

  • Transducer Type: Configure 4–20 mA, 0–10 V, or ±10 V per channel.

  • Transducer Loop Power: External 24 VDC supplies required.

  • Sensor Drift Detection: Enable to predict sensor failures.

  • Calibration Management: Use GE ToolboxST to review factory certificate and perform self-calibration.

  • Controller Firmware: Requires Mark VIe processor firmware v9.5 or later.

  • Spare Strategy: Keep one spare per turbine; lead times 8–14 weeks.

  • Retrofit: Direct replacement for IS200TTURH1B—regenerate configuration in GE ToolboxST for 24-channel mapping.

Important Cautions

  1. No Hot-Swap: De-energize rack before insertion/removal.

  2. Thermocouple Polarity: Reverse connection produces negative readings.

  3. RTD Polarity: For 3-wire RTDs, ensure leads are correctly connected.

  4. Transducer Polarity: Observe correct polarity for 4–20 mA loops and voltage inputs.

  5. CJC Protection: Do not apply conformal coating or tape over the terminal block area.

  6. Transducer Loop Power: External 24 VDC required.

  7. Grounding: Connect AGND to Mark VIe system ground at single star point.

  8. Shield Termination: Ground shields only at cabinet end.

  9. ESD Handling: Use grounded wrist straps; field repair not possible.

  10. Temperature Rating: Verify cabinet ambient does not exceed +70°C or fall below –40°C.

  11. Reference Validation: Yellow LED indicates reference drift—perform self-calibration or schedule factory recalibration.

  12. Self-Calibration: Perform only when board is de-energized and free from field wiring faults.

  13. Calibration Records: Factory certificate stored onboard—do not modify via external tools.

  14. CJC Redundancy Status: Blue LED flashing indicates one CJC sensor failed—schedule service.

  15. Lead-Wire Imbalance: Monitor alerts—investigate wiring mismatches.

  16. Sensor Drift Alerts: Investigate drift alerts to replace aging sensors before failure.

  17. Channel Mapping: With 24 universal channels, verify field wiring maps to correct ToolboxST assignments.

  18. Input Overload: Sustained transducer input >30 V or >50 mA may damage input circuitry.

  19. Wiring Density: With 24 channels, ensure adequate cabinet space and cable management.

WESTINGHOUSE 1C31227G01
Automation direct EZ-S6C-K
HONEYWELL CC-TCNT01
FOXBORO FBM201