IS200TRPGH2B GE

¥999.00

IS200TRPGH2B is an advanced high-capacity Terminal Board within the GE Mark VIe Speedtronic control system, designed as a field termination and signal conditioning interface for redundant transducer power supply with extended channel capacity, enhanced current capacity, extended temperature range, and comprehensive diagnostics. This board provides centralized termination for powering and monitoring field-mounted transducers with redundancy requirements, such as pressure transmitters, temperature transmitters, position transducers, and other 2-wire or 4-wire sensors where high reliability is essential. The IS200TRPGH2B features integrated termination points for redundant transducer power supply with built-in voltage regulation, filtering, enhanced isolation, and diagnostics. It offers dual-redundant transducer power channels with extended channel capacity, higher current capacity, automatic failover, and comprehensive diagnostics including reference validation.

Category:

Description

Product Parameters

Parameter Specification
Brand / Series GE Mark VIe Speedtronic
Model IS200TRPGH2B
Redundant Power Channels 12 redundant pairs (24 total power outputs) — upgraded from 8 pairs
Output Voltage 24 VDC (regulated, programmable per channel)
Output Current 100 mA per channel (2.4 A total maximum) — upgraded from 1.6 A
Input Voltage Range 24/48/125 VDC (auto-ranging, from Mark VIe rack)
Voltage Regulation ±0.05%
Ripple/Noise < 5 mV peak-to-peak
Redundancy Logic Automatic failover (hardware-based, < 5 ms)
Isolation 2000 VAC (channel-to-channel and field-to-system)
Diagnostics Overcurrent detection, short-circuit detection, under/over-voltage monitoring, open-circuit detection, primary/secondary power status monitoring, reference validation
Status Indication 12 green LEDs (primary active), 12 green LEDs (redundant active), 24 red LEDs (fault), 2 red summary fault LEDs, 1 yellow LED (reference/calibration status)
Operating Temperature –40°C to +70°C
Storage Temperature –55°C to +85°C
Mounting VME rack-mount terminal board with front-panel I/O connectors
Backplane Interface VME64x (A24/A32, D16/D32/D64)
EMC Compliance IEC 61000-4 Level 4

Advantages & Key Features

  • Extended Redundant Capacity: 12 redundant transducer power pairs (24 total outputs) in a single VME slot—50% more capacity than IS200TRPGH1BDD (8 pairs). Ideal for larger turbine systems with extensive critical transducer power requirements.

  • Higher Total Current: 100 mA per channel with 2.4 A total capacity—50% more total current than IS200TRPGH1BDD (1.6 A).

  • Highest Accuracy Regulation: ±0.05% voltage regulation ensures ultra-stable transducer operation.

  • Ultra-Low Ripple/Noise: < 5 mV peak-to-peak ripple ensures clean power for sensitive transducers.

  • Fast Failover: < 5 ms hardware failover ensures minimal power interruption.

  • Extended Temperature Range: –40°C to +70°C operation makes IS200TRPGH2B suitable for extreme environments.

  • Enhanced Isolation: 2000 VAC isolation provides superior protection for the Mark VIe backplane.

  • Comprehensive Diagnostics: Overcurrent, short-circuit, under/over-voltage, open-circuit, power status monitoring, and reference validation.

  • High-Density Status Indication: 12 primary and 12 redundant status LEDs enable rapid on-site troubleshooting.

  • ToolboxST Integration: Full configuration, monitoring, and diagnostics via GE ToolboxST.

  • Drop-In Replacement: Direct replacement for IS200TRPGH1BDDIS200TRPGH1B, and earlier redundant transducer power terminal boards.

Application Fields

  • Gas & Steam Turbines (GE Frame 6B/7EA/9E/HA): Redundant power for critical pressure transmitters (fuel gas, steam pressure), temperature transmitters, and position transducers.

  • Combined Cycle Plants: Redundant power for HRSG critical pressure and temperature transmitters.

  • Compressor Stations: Redundant power for critical suction/discharge pressure transmitters.

  • Nuclear Power Plants: Critical transducer power where redundancy, calibration traceability, and high reliability are mandated.

  • Safety-Critical Applications: Powering transducers in safety instrumented systems (SIS).

  • Arctic & Desert Installations: Extreme-environment critical transducer power applications.

Comparison with Competing Products

Feature GE IS200TRPGH2B GE IS200TRPGH1BDD (8 pairs) GE IS200TRPGH1B (8 pairs) Competitor A (Redundant Power) Competitor B (Power Supply)
Redundant Pairs 12 (24 outputs) 8 (16 outputs) 8 (16 outputs) 4 (8 outputs) 0
Output Current 100 mA/channel 100 mA/channel 100 mA/channel 40 mA/channel 50 mA/channel
Total Current 2.4 A 1.6 A 1.6 A 0.32 A 0.4 A
Failover Time < 5 ms < 5 ms < 10 ms < 50 ms N/A
Voltage Regulation ±0.05% ±0.05% ±0.05% ±1% ±0.5%
Isolation 2000 VAC 2000 VAC 2000 VAC 1000 VAC 500 VDC
Operating Temp –40°C to +70°C –40°C to +70°C –40°C to +70°C 0°C to 50°C 0°C to 60°C
Reference Validation Yes Yes Yes No No

Key AdvantageIS200TRPGH2B delivers 12 redundant transducer power pairs (24 outputs)—the highest channel density in the Mark VIe redundant transducer power terminal family, with 50% more capacity than IS200TRPGH1BDD—combined with 100 mA per channel, < 5 ms failover, ±0.05% regulation, 2000 VAC isolation, extended –40°C to +70°C temperature range, and comprehensive diagnostics including reference validation—making it the premier solution for large turbine systems requiring maximum-density, high-current, uninterrupted transducer power in extreme environments.

Selection Guidelines & Recommendations

  • Redundancy Configuration: Determine critical transducers requiring redundant power—up to 12 redundant pairs per board.

  • Output Voltage: Configure per-channel output voltage (default 24 VDC) in GE ToolboxST.

  • Current Requirements: Verify each transducer’s current draw does not exceed 100 mA per channel.

  • Total Power: Ensure total current across all channels does not exceed 2.4 A.

  • Diagnostic Configuration: Enable overcurrent, short-circuit, power status monitoring, and reference validation for critical transducers.

  • Failover Testing: Test failover operation by simulating primary power loss—verify automatic switchover within < 5 ms.

  • Controller Firmware: Requires Mark VIe processor firmware v9.5 or later.

  • Wiring Guidelines: Use shielded twisted-pair cables. Maintain shield grounding only at the Mark VIe cabinet end.

  • Spare Strategy: Keep one spare per turbine; lead times 8–14 weeks.

  • Retrofit: Direct replacement for IS200TRPGH1BDDIS200TRPGH1B, and IS200TRPGH1A—regenerate configuration in GE ToolboxST for 12-pair mapping.

Important Cautions

  1. No Hot-Swap: De-energize rack before insertion/removal.

  2. Power Polarity: Observe correct polarity for transducer connections—reverse polarity may damage field devices.

  3. Current Limit: Do not exceed 100 mA per channel—overcurrent protection will trip and latch.

  4. Total Power: Do not exceed 2.4 A total across all channels.

  5. Short-Circuit: If a short is detected, the channel will latch off. Clear the fault and reset via GE ToolboxST.

  6. Failover Testing: Test failover operation by simulating primary power loss—verify automatic switchover within < 5 ms.

  7. Grounding: Connect AGND to Mark VIe system ground at single star point.

  8. Shield Termination: Ground transducer cable shields only at cabinet end.

  9. ESD Handling: Use grounded wrist straps; field repair not possible.

  10. Temperature Rating: Verify cabinet ambient does not exceed +70°C or fall below –40°C.

  11. Reference Validation: Yellow LED indicates reference drift—schedule factory recalibration if illuminated.

  12. Channel Mapping: With 12 redundant pairs (24 channels), verify field wiring maps to correct ToolboxST channel numbers.

  13. Redundancy Verification: Confirm both primary and secondary power sources are operational after installation.

  14. Wiring Density: With 24 transducer power connections, ensure adequate cabinet space and cable management to maintain proper airflow.

A-B 1756-PA72
BARKSDALE TS2000/0+100C/420-1/G1/4
SIEMENS MOORE 16137-215

Reviews

There are no reviews yet.

Be the first to review “IS200TRPGH2B GE”

Your email address will not be published. Required fields are marked *

Post comment