IS200TRPGH1A GE

¥999.00

IS200TRPGH1A is a Terminal Board within the GE Mark VIe Speedtronic control system, designed as a field termination and signal conditioning interface for redundant transducer power supply in critical turbine control applications. This board provides centralized termination for powering and monitoring field-mounted transducers with redundancy requirements, such as pressure transmitters, temperature transmitters, position transducers, and other 2-wire or 4-wire sensors where high reliability is essential. The IS200TRPGH1A features integrated termination points for redundant transducer power supply with built-in voltage regulation, filtering, enhanced isolation, and diagnostics. It offers dual-redundant transducer power channels with automatic failover and comprehensive diagnostics.

Category:

Description

Product Parameters

Parameter Specification
Brand / Series GE Mark VIe Speedtronic
Model IS200TRPGH1A
Redundant Power Channels 8 redundant pairs (16 total power outputs)
Output Voltage 24 VDC (regulated, programmable per channel)
Output Current 50 mA per channel (800 mA total maximum)
Input Voltage Range 24/48/125 VDC (auto-ranging, from Mark VIe rack)
Voltage Regulation ±0.1%
Ripple/Noise < 10 mV peak-to-peak
Redundancy Logic Automatic failover (hardware-based, < 10 ms)
Isolation 1500 VAC (channel-to-channel and field-to-system)
Diagnostics Overcurrent detection, short-circuit detection, under/over-voltage monitoring, open-circuit detection, primary/secondary power status monitoring
Status Indication 8 green LEDs (primary active), 8 green LEDs (redundant active), 16 red LEDs (fault), 2 red summary fault LEDs
Operating Temperature –30°C to +65°C
Storage Temperature –55°C to +85°C
Mounting VME rack-mount terminal board with front-panel I/O connectors
Backplane Interface VME64x (A24/A32, D16/D32/D64)
EMC Compliance IEC 61000-4 Level 4

Advantages & Key Features

  • Redundant Transducer PowerIS200TRPGH1A provides 8 redundant transducer power pairs with automatic failover (< 10 ms), ensuring uninterrupted power to critical field devices.

  • High Reliability: Dual power sources per transducer with automatic cross-checking and failover.

  • High Channel Density: 8 redundant pairs (16 total outputs) in a single VME slot.

  • Programmable Output Voltage: Per-channel adjustable 24 VDC output via GE ToolboxST.

  • Comprehensive Diagnostics: Overcurrent, short-circuit, under/over-voltage, open-circuit, and primary/secondary power status monitoring.

  • Opto-Isolation: 1500 VAC isolation protects the Mark VIe backplane from field wiring faults.

  • ToolboxST Integration: Full configuration, monitoring, and diagnostics via GE ToolboxST.

  • Drop-In Replacement: Direct replacement for earlier GE redundant transducer power terminal boards.

Application Fields

  • Gas & Steam Turbines (GE Frame 6B/7EA/9E/HA): Redundant power for critical pressure transmitters (fuel gas, steam pressure), temperature transmitters, and position transducers.

  • Combined Cycle Plants: Redundant power for HRSG critical pressure and temperature transmitters.

  • Compressor Stations: Redundant power for critical suction/discharge pressure transmitters.

  • Nuclear Power Plants: Critical transducer power where redundancy is mandated.

  • Safety-Critical Applications: Powering transducers in safety instrumented systems (SIS).

Comparison with Competing Products

Feature GE IS200TRPGH1A Competitor A (Redundant Power Module) Competitor B (Power Supply Module)
Redundant Pairs 8 (16 outputs) 4 (8 outputs) 0 (non-redundant)
Output Current 50 mA/channel 40 mA/channel 50 mA/channel
Failover Time < 10 ms hardware < 50 ms software N/A
Diagnostics Overcurrent, short, under/over-voltage, open, status Overcurrent only Overcurrent only
Isolation 1500 VAC 1000 VAC 500 VDC
Operating Temp –30°C to +65°C 0°C to 50°C 0°C to 60°C

Key AdvantageIS200TRPGH1A provides 8 redundant transducer power pairs—double the density of competing redundant power modules—with < 10 ms hardware failover and comprehensive diagnostics, making it ideal for critical turbine applications requiring uninterrupted transducer power.

Selection Guidelines & Recommendations

  • Redundancy Configuration: Determine critical transducers requiring redundant power—up to 8 redundant pairs per board.

  • Output Voltage: Configure per-channel output voltage (default 24 VDC) in GE ToolboxST.

  • Current Requirements: Verify each transducer’s current draw does not exceed 50 mA per channel.

  • Diagnostic Configuration: Enable overcurrent, short-circuit, and power status monitoring for critical transducers.

  • Controller Firmware: Requires Mark VIe processor firmware v8.0 or later.

  • Wiring Guidelines: Use shielded twisted-pair cables. Maintain shield grounding only at the Mark VIe cabinet end.

  • Spare Strategy: Keep one spare per turbine; lead times 6–10 weeks.

  • Retrofit: Direct replacement—regenerate configuration in GE ToolboxST.

Important Cautions

  1. No Hot-Swap: De-energize rack before insertion/removal.

  2. Power Polarity: Observe correct polarity for transducer connections—reverse polarity may damage field devices.

  3. Current Limit: Do not exceed 50 mA per channel—overcurrent protection will trip and latch.

  4. Short-Circuit: If a short is detected, the channel will latch off. Clear the fault and reset via GE ToolboxST.

  5. Failover Testing: Test failover operation by simulating primary power loss—verify automatic switchover.

  6. Grounding: Connect AGND to Mark VIe system ground at single star point.

  7. Shield Termination: Ground transducer cable shields only at cabinet end.

  8. ESD Handling: Use grounded wrist straps; field repair not possible.

  9. Channel Mapping: Verify field wiring maps to correct ToolboxST channel numbers.

  10. Redundancy Verification: Confirm both primary and secondary power sources are operational after installation.

GE IC695CHS012
A-B 1756-IF16
A-B 1756-DNB
A-B 1786-RG6F

Reviews