IS200TRPAS1A GE

¥999.00

IS200TRPAS1A is a high-capacity Terminal Board within the GE Mark VIe Speedtronic control system, designed as a field termination and signal conditioning interface for transducer power supply with enhanced channel capacity, extended temperature range, and comprehensive diagnostics. This board provides centralized termination for powering and monitoring field-mounted transducers such as pressure transmitters, temperature transmitters, position transducers, and other 2-wire or 4-wire sensors, connecting to the Mark VIe main VME-based controller processors via front-panel I/O cables. The IS200TRPAS1A features integrated termination points for transducer power supply with built-in voltage regulation, filtering, enhanced isolation, and diagnostics. It offers 32 isolated transducer power channels with adjustable voltage output and comprehensive diagnostics including reference validation.

Category:

Description

Product Parameters

Parameter Specification
Brand / Series GE Mark VIe Speedtronic
Model IS200TRPAS1A
Transducer Power Channels 32 isolated channels — upgraded from 16 channels
Output Voltage 24 VDC (regulated, programmable per channel)
Output Current 50 mA per channel (1.6 A total maximum)
Input Voltage Range 24/48/125 VDC (auto-ranging, from Mark VIe rack)
Voltage Regulation ±0.1%
Ripple/Noise < 10 mV peak-to-peak
Isolation 2000 VAC (channel-to-channel and field-to-system) — upgraded from 1500 VAC
Diagnostics Overcurrent detection, short-circuit detection, under/over-voltage monitoring, open-circuit detection, reference validation
Status Indication 32 green LEDs (channel active), 32 red LEDs (channel fault), 2 red summary fault LEDs, 1 yellow LED (reference/calibration status)
Operating Temperature –40°C to +70°C — upgraded from –30°C to +65°C
Storage Temperature –55°C to +85°C
Mounting VME rack-mount terminal board with front-panel I/O connectors
Backplane Interface VME64x (A24/A32, D16/D32/D64)
EMC Compliance IEC 61000-4 Level 4

Advantages & Key Features

  • Maximum Channel Density: 32 isolated transducer power channels in a single VME slot—double the density of IS200TRPAH1AFB (16 channels) and four times that of competing modules. Ideal for large turbine systems with extensive transducer power requirements.

  • Programmable Output Voltage: Per-channel adjustable 24 VDC output via GE ToolboxST.

  • Extended Temperature Range: –40°C to +70°C operation makes IS200TRPAS1A suitable for extreme environments.

  • Enhanced Isolation: 2000 VAC isolation provides superior protection for the Mark VIe backplane.

  • Comprehensive Diagnostics: Overcurrent, short-circuit, under/over-voltage, open-circuit, and reference validation per channel.

  • High-Density Status Indication: 32 green/red LEDs enable rapid on-site troubleshooting.

  • ToolboxST Integration: Full configuration, monitoring, and diagnostics via GE ToolboxST.

  • Drop-In Replacement: Direct replacement for IS200TRPAH1AFBIS200TRPAH1A, and earlier transducer power terminal boards.

Application Fields

  • Gas & Steam Turbines (GE Frame 6B/7EA/9E/HA): Powering pressure transmitters for fuel gas, lube oil, cooling water; temperature transmitters; position transducers for control valves.

  • Combined Cycle Plants: Powering HRSG pressure and temperature transmitters.

  • Compressor Stations: Powering suction/discharge pressure transmitters and temperature transmitters.

  • Aeroderivative Turbines: Powering fuel flow, oil pressure, and temperature transmitters.

  • Arctic & Desert Installations: Extreme-environment transducer power applications with high channel count.

  • Offshore Platforms: Marine enclosures with salt-spray and wide temperature swings.

Comparison with Competing Products

Feature GE IS200TRPAS1A GE IS200TRPAH1AFB (16-ch) GE IS200TRPAH1A (16-ch) Competitor A (Transducer Power) Competitor B (Power Supply)
Power Channels 32 isolated 16 isolated 16 isolated 8 isolated 8 non-isolated
Output Current 50 mA/channel 100 mA/channel 50 mA/channel 40 mA/channel 50 mA/channel
Voltage Regulation ±0.1% ±0.05% ±0.1% ±1% ±0.5%
Diagnostics Overcurrent, short, under/over-voltage, open, reference Overcurrent, short, under/over-voltage, open, reference Overcurrent, short, under/over-voltage, open Overcurrent only Overcurrent only
Isolation 2000 VAC 2000 VAC 1500 VAC 1000 VAC 500 VDC
Operating Temp –40°C to +70°C –40°C to +70°C –30°C to +65°C 0°C to 50°C 0°C to 60°C
Reference Validation Yes Yes No No No

Key AdvantageIS200TRPAS1A delivers 32 isolated transducer power channels—double the density of IS200TRPAH1AFB and four times that of competing modules—with 2000 VAC isolation, extended –40°C to +70°C temperature range, and comprehensive diagnostics including reference validation, making it the premier solution for large turbine systems requiring high-density transducer power in extreme environments.

Selection Guidelines & Recommendations

  • Channel Count: Determine number of transducers requiring power—up to 32 per board.

  • Output Voltage: Configure per-channel output voltage (default 24 VDC) in GE ToolboxST.

  • Current Requirements: Verify each transducer’s current draw does not exceed 50 mA per channel.

  • Diagnostic Configuration: Enable overcurrent, short-circuit, and reference validation for critical transducers.

  • Controller Firmware: Requires Mark VIe processor firmware v9.0 or later.

  • Wiring Guidelines: Use shielded twisted-pair cables. Maintain shield grounding only at the Mark VIe cabinet end.

  • Spare Strategy: Keep one spare per turbine; lead times 8–12 weeks.

  • Retrofit: Direct replacement for IS200TRPAH1AFB and IS200TRPAH1A—regenerate configuration in GE ToolboxST for 32-channel mapping.

Important Cautions

  1. No Hot-Swap: De-energize rack before insertion/removal.

  2. Power Polarity: Observe correct polarity for transducer connections—reverse polarity may damage field devices.

  3. Current Limit: Do not exceed 50 mA per channel—overcurrent protection will trip and latch.

  4. Short-Circuit: If a short is detected, the channel will latch off. Clear the fault and reset via GE ToolboxST.

  5. Grounding: Connect AGND to Mark VIe system ground at single star point.

  6. Shield Termination: Ground transducer cable shields only at cabinet end.

  7. ESD Handling: Use grounded wrist straps; field repair not possible.

  8. Temperature Rating: Verify cabinet ambient does not exceed +70°C or fall below –40°C.

  9. Reference Validation: Yellow LED indicates reference drift—schedule factory recalibration if illuminated.

  10. Voltage Verification: Verify transducer voltage requirements before powering up.

  11. Channel Mapping: With 32 channels, verify field wiring maps to correct ToolboxST channel numbers.

  12. Wiring Density: With 32 transducer power connections, ensure adequate cabinet space and cable management to maintain proper airflow.

п OP032
A-B 1756-IF16
A-B 1746-NO4I
A-B 1746-NI8

Reviews

There are no reviews yet.

Be the first to review “IS200TRPAS1A GE”

Your email address will not be published. Required fields are marked *

Post comment