IS200TRLYH2C GE Mark

¥999.00

IS200TRLYH2C is a high-channel-density Terminal Board within the GE Mark VIe Speedtronic control system, designed as a field termination and signal conditioning interface for relay output signals with extended channel capacity, enhanced contact rating, extended temperature range, and comprehensive diagnostics. This board provides centralized termination for discrete output signals to field actuators such as solenoids, contactors, motor starters, alarms, and trip actuators, connecting to the Mark VIe main VME-based controller processors via front-panel I/O cables. The IS200TRLYH2C features integrated termination points for relay outputs with built-in signal conditioning including relay isolation, enhanced surge suppression, and diagnostics. It offers 32 isolated relay output channels with high contact rating, enhanced suppression, comprehensive diagnostics including reference validation, and extended temperature range.

Category:

Description

Product Parameters

Parameter Specification
Brand / Series GE Mark VIe Speedtronic
Model IS200TRLYH2C
Relay Outputs 32 isolated channels (Form C, SPDT)
Contact Rating 8A @ 250 VAC / 30 VDC (resistive load)
Switching Voltage 250 VAC / 30 VDC maximum
Switching Current 8A maximum per channel
Inrush Capability 15A for 50 ms (motor/inductive loads)
Coil Voltage 24 VDC (internally supplied from Mark VIe rack)
Coil Current 40 mA per relay (1.28 A total maximum)
Response Time < 8 ms (energize), < 4 ms (de-energize)
Electrical Life 150,000 operations at rated load
Mechanical Life 1,500,000 operations (no load)
Suppression Built-in flyback diodes (DC loads), RC snubbers (AC loads), and MOV (transient suppression)
Isolation 2000 VAC (channel-to-channel and field-to-system)
Diagnostics Coil open-circuit detection, coil short-circuit detection, welded contact monitoring, contact wear monitoring, reference validation
Status Indication 32 green LEDs (output energized), 32 red LEDs (fault per channel), 2 red summary fault LEDs, 1 yellow LED (reference/calibration status)
Operating Temperature –40°C to +70°C
Storage Temperature –55°C to +85°C
Mounting VME rack-mount terminal board with front-panel I/O connectors
Backplane Interface VME64x (A24/A32, D16/D32/D64)
EMC Compliance IEC 61000-4 Level 4

Advantages & Key Features

  • High Channel Density: 32 isolated relay outputs in a single VME slot—providing double the channel count of IS200TRLYH1B (16 channels) and 33% more than IS200TRLYH1C (24 channels). Ideal for large turbine systems with extensive actuator control requirements.

  • High Contact Rating: 8A per channel with 15A inrush capability enables direct control of large solenoids, contactors, and valve actuators.

  • Extended Temperature Range: –40°C to +70°C operation makes IS200TRLYH2C suitable for extreme environments.

  • Enhanced Isolation: 2000 VAC isolation provides superior protection for the Mark VIe backplane.

  • Enhanced Suppression: Integrated flyback diodes, RC snubbers, and MOVs protect relay contacts and driver circuits.

  • Fast Response: < 8 ms energize and < 4 ms de-energize times ensure precise control.

  • Comprehensive Diagnostics: Coil open/short, welded contact, wear monitoring, and reference validation.

  • High-Density Status Indication: 32 green/red LEDs enable rapid on-site troubleshooting.

  • ToolboxST Integration: Full configuration, monitoring, and diagnostics via GE ToolboxST.

  • Drop-In Replacement: Direct replacement for IS200TRLYH1DIS200TRLYH1C, and earlier relay output terminal boards.

Application Fields

  • Gas & Steam Turbines (GE Frame 6B/7EA/9E/HA): Fuel gas shut-off valves, emergency stop solenoids, alarm annunciators, lube oil pump starters, generator breaker trip coils, cooling fan starters, auxiliary system actuators.

  • Combined Cycle Plants: Steam turbine extraction valves, bypass actuators, HRSG damper controls, condensate pump starters.

  • Compressor Stations: Anti-surge valve solenoids, discharge blow-down valves, station shutdown relays.

  • Arctic & Desert Installations: Extreme-environment actuator control.

  • Nuclear Power Plants: Critical actuator control requiring documented diagnostics and reference validation.

Comparison with Competing Products

Feature GE IS200TRLYH2C GE IS200TRLYH1D (32-ch) GE IS200TRLYH1C (24-ch) GE IS200TRLYH1B (16-ch) Competitor A (Relay Output) Competitor B (Relay Module)
Relay Outputs 32 isolated 32 isolated 24 isolated 16 isolated 8 isolated 8 isolated
Contact Rating 8A (15A inrush) 8A (15A inrush) 8A (15A inrush) 8A (15A inrush) 5A 2A
Suppression Flyback, RC, MOV Flyback, RC, MOV Flyback, RC, MOV Flyback, RC, MOV External required External required
Diagnostics Coil open/short, welded, wear, reference Coil open/short, welded, wear, reference Coil open/short, welded, wear Coil open/short, welded, wear Coil open only None
Isolation 2000 VAC 2000 VAC 1500 VAC 1500 VAC 1000 VAC 500 VDC
Operating Temp –40°C to +70°C –40°C to +70°C –30°C to +65°C –30°C to +65°C 0°C to 50°C 0°C to 60°C
Reference Validation Yes Yes No No No No

Key AdvantageIS200TRLYH2C delivers 32 isolated relay outputs with 8A contact rating, 15A inrush capability, 2000 VAC isolation, extended –40°C to +70°C temperature range, and comprehensive diagnostics including reference validation—making it a premier solution for large turbine systems requiring high-density, high-current actuator control in extreme environments.

Selection Guidelines & Recommendations

  • Channel Count: 32 relay outputs per board—ideal for large turbine systems.

  • Contact Rating: Confirm load requirements do not exceed 8A @ 250 VAC or 8A @ 30 VDC. For inductive loads, de-rate to 5A.

  • Inrush Capability: 15A for 50 ms—verify load inrush does not exceed this.

  • Load Protection: For highly inductive DC loads, add external varistors.

  • Diagnostic Configuration: Enable welded contact, wear monitoring, and reference validation for critical safety circuits.

  • Controller Firmware: Requires Mark VIe processor firmware v9.0 or later.

  • Spare Strategy: Keep one spare per turbine; lead times 8–14 weeks.

  • Retrofit: Direct replacement for IS200TRLYH1DIS200TRLYH1C, and IS200TRLYH1B—regenerate configuration in GE ToolboxST for 32-channel mapping.

Important Cautions

  1. No Hot-Swap: De-energize rack before insertion/removal.

  2. Wiring Polarity: For DC loads, observe correct polarity—reverse polarity shorts through the flyback diode.

  3. Contact Protection: For loads exceeding 8A, use external contactors.

  4. Grounding: Connect chassis ground at single star point.

  5. Shield Termination: Ground output cable shields only at cabinet end.

  6. ESD Handling: Use grounded wrist straps; field repair not possible.

  7. Temperature Rating: Verify cabinet ambient does not exceed +70°C or fall below –40°C.

  8. Reference Validation: Yellow LED indicates reference drift—schedule factory recalibration if illuminated.

  9. Welded Contact Detection: Refer to GE wiring diagram IS200TRLYH2C-DWG.

  10. Wear Monitoring: Set operational thresholds in GE ToolboxST for maintenance alerts.

  11. Power Supply: Ensure adequate current for all active outputs (40 mA × 32 = 1.28 A max).

  12. Channel Mapping: With 32 channels, verify field wiring maps to correct ToolboxST channel numbers.

EMERSON 12P0631X012
BENTLY 149992-01
SIEMENS C98043-A7001-L2