IS200TBCIS2C GE

¥999.00

IS200TBCIS2C is a high-capacity Terminal Board within the GE Mark VIe Speedtronic control system, designed as a high-density field termination and signal conditioning interface for discrete input signals optimized for 24 VDC operation. This board provides centralized termination for dry-contact sensors such as pressure switches, temperature switches, level switches, limit switches, and emergency stop pushbuttons, connecting to the Mark VIe main VME-based controller processors via front-panel I/O cables. The IS200TBCIS2C features integrated termination points for discrete inputs with built-in signal conditioning including opto-isolation, filtering, and surge protection. It offers 64 isolated discrete input channels with extended operating temperature range and enhanced diagnostics including input voltage monitoring.

Category:

Description

Product Parameters

Parameter Specification
Brand / Series GE Mark VIe Speedtronic
Model IS200TBCIS2C
Discrete Inputs 64 isolated channels (dry contact / volt-free)
Input Voltage Range 24 VDC only (opto-isolated) — optimized for 24 VDC systems
Input Current 3–6 mA typical
Debounce Time Programmable 0–100 ms (default 6 ms)
Event Time-Stamp Resolution 1 ms (hardware-based)
Isolation 2000 VAC (channel-to-channel and field-to-system)
Diagnostics Open-wire detection, short-circuit detection, stuck-contact monitoring, input voltage monitoring
Status Indication 64 green LEDs (input active), 2 red LEDs (diagnostic fault summary)
Operating Temperature –40°C to +70°C
Storage Temperature –55°C to +85°C
Mounting VME rack-mount terminal board with front-panel I/O connectors
Backplane Interface VME64x (A24/A32, D16/D32/D64)
EMC Compliance IEC 61000-4 Level 4

Advantages & Key Features

  • Maximum Channel Density: 64 isolated discrete inputs in a single VME slot—eight times that of competing 8-channel modules. Ideal for large turbine systems with extensive 24 VDC switch monitoring.

  • Optimized for 24 VDC: Dedicated 24 VDC input range provides optimal sensitivity and reliability for plants with 24 VDC control systems, eliminating the complexity of auto-ranging circuitry.

  • Extended Temperature Range: –40°C to +70°C operation makes IS200TBCIS2C suitable for arctic, desert, and unheated turbine enclosures.

  • Enhanced Isolation: 2000 VAC optical isolation provides superior protection for the Mark VIe backplane from field wiring faults and surges.

  • Programmable Debouncing: 0–100 ms per-channel debounce eliminates false trips from contact bounce.

  • 1 ms Hardware Time-Stamping: Enables sequence-of-events (SOE) recording for post-trip forensic analysis.

  • Comprehensive Diagnostics: Open-wire, short-circuit, stuck-contact, and input voltage monitoring per channel.

  • High-Density Status Indication: 64 green LEDs enable rapid on-site channel status identification.

  • ToolboxST Integration: Full configuration, monitoring, and diagnostics via GE ToolboxST.

  • Drop-In Replacement: Direct replacement for earlier GE discrete input terminal boards.

Application Fields

  • Gas & Steam Turbines (GE Frame 6B/7EA/9E/HA): Emergency stop pushbuttons, bearing vibration trip contacts, exhaust temperature switch alarms, fuel gas valve limit switches, flame detector relay contacts, lube oil pressure switches, cooling water flow switches, generator status contacts, auxiliary system permissives.

  • Combined Cycle Plants: HRSG drum level switches, steam pressure switches, condensate pump status, bypass valve position switches.

  • Compressor Stations: Suction/discharge pressure switches, surge control permissives, filter differential pressure switches.

  • Arctic & Desert Installations: Extreme-environment turbine control cabinets with 24 VDC systems.

  • Offshore Platforms: Marine enclosures with salt-spray and wide temperature swings.

Comparison with Competing Products

Feature GE IS200TBCIS2C GE IS200TBCIH2C (auto-range) Competitor A (Emerson) Competitor B (Siemens)
Discrete Inputs 64 isolated 64 isolated 8 isolated 8 isolated
Voltage Range 24 VDC only 24/48/125 VDC 24 VDC only 24 VDC only
Debounce 0–100 ms (per-channel) 0–100 ms (per-channel) Fixed 10 ms Programmable (global)
Time-Stamping 1 ms hardware 1 ms hardware 5 ms software 2 ms software
Isolation 2000 VAC 2000 VAC 1000 VAC 500 VDC
Operating Temp –40°C to +70°C –40°C to +70°C 0°C to 50°C 0°C to 60°C
Voltage Monitoring Yes Yes No No

Key AdvantageIS200TBCIS2C provides 64 isolated 24 VDC inputs with 2000 VAC isolation, extended –40°C to +70°C temperature range, and comprehensive diagnostics including voltage monitoring—making it the premier solution for extreme-environment, high-channel-count 24 VDC turbine monitoring applications.

Selection Guidelines & Recommendations

  • Voltage Verification: Confirm plant uses 24 VDC control voltage—IS200TBCIS2C is not compatible with 48 VDC or 125 VDC systems.

  • Channel Count: 64 channels per board—sufficient for most large turbine systems.

  • Debounce Configuration: For vibration-prone switches, set 10–20 ms. For safety circuits (ESD), use 0–6 ms.

  • Event Time-Stamping: Enable SOE recording via GE ToolboxST—requires controller firmware v8.0 or later.

  • Diagnostic Configuration: Enable open-wire, short-circuit, and voltage monitoring for critical circuits.

  • Controller Firmware: Requires Mark VIe processor firmware v8.0 or later.

  • Spare Strategy: Keep one spare per turbine; lead times 8–12 weeks.

  • Retrofit: Direct replacement—regenerate configuration in GE ToolboxST for 64-channel mapping.

Important Cautions

  1. No Hot-Swap: De-energize rack before insertion/removal.

  2. 24 VDC Only: Do not apply 48 VDC or 125 VDC—damage will occur.

  3. Wiring Polarity: Observe correct polarity—reverse polarity triggers fault LED.

  4. Grounding: Connect ISO_GND to chassis ground at single star point.

  5. Shield Termination: Ground shields only at cabinet end.

  6. ESD Handling: Use grounded wrist straps; field repair not possible.

  7. Debounce Trade-Off: Higher debounce rejects bounce but introduces delay—set as low as possible for safety circuits.

  8. Temperature Rating: Verify cabinet ambient does not exceed +70°C or fall below –40°C.

  9. Input Voltage Monitoring: Enable voltage monitoring for critical channels to detect power supply degradation.

  10. Channel Mapping: With 64 channels, verify field wiring maps to correct ToolboxST channel numbers.

  11. Input Current: Ensure 24 VDC supply provides sufficient current for all 64 channels (3–6 mA per channel = 192–384 mA total plus margin).

ABB PM554-RP-AC
A-B 1771-DB
A-B 1756-PB72
A-B 22B-D010N104

Reviews

There are no reviews yet.