Description
Technical Specifications
| Parameter | Specification |
|---|---|
| Manufacturer | General Electric |
| Model | IS200RCSAG1A |
| Remote Control Functions | Remote monitoring, control commands, status reporting |
| Serial Adapter Functions | Serial device integration, protocol conversion |
| Gateway Functions | Data routing, system integration |
| Communication | Serial interfaces (RS-232/485), highway integration |
| Supported Protocols | Modbus RTU, GE serial protocols |
| Power | +5V DC / 2.0A, ±15V DC / 0.4A |
| Temp Range | -30°C to +65°C |
| MTBF | > 108,000 hours |
| Revision Note | “A” suffix = specific hardware/firmware configuration |
Advantages and Key Features
Dedicated Remote Control and Serial Adapter Gateway: The IS200RCSAG1A provides specialized remote control and serial device integration with gateway communication.
Remote Control Functions: The IS200RCSAG1A enables remote monitoring and control.
Serial Adapter Functions: Handles serial device integration and protocol conversion.
Gateway Communication: Integrates remote control data with control networks.
Application Fields and Case Studies
Used in remote control applications, serial device integration, and gateway communication for remote monitoring and control. In a 600 MW plant, the IS200RCSAG1A provided reliable remote control and serial adapter gateway functions.
Comparison with Competing Products
| Dimension | IS200RCSAG1A | IS200RAPAG1BCA | IS200ISBAH1ABA |
|---|---|---|---|
| Primary Function | Remote control + serial adapter | Relay/alarm/protection | Serial adapter + highway |
| Remote Control | Yes | No | No |
| Serial Integration | Yes | No | Yes |
| VME Integration | Direct | Direct | Direct |
Selection Recommendations
Choose IS200RCSAG1A for remote control and serial adapter gateway applications. Verify compatibility with your specific remote control and serial device requirements. Deploy for remote monitoring and control systems.
Precautions and Important Notes
Use ESD-safe handling. Verify field wiring and serial connections. Confirm compatibility with your specific remote control and serial device requirements. Never interrupt firmware updates. Board draws 2.0A – verify rack power capacity. Document all configurations. Store spares in anti-static packaging. Do not mix variants in redundant pairs. Allow 30 seconds boot time. Test all remote control and gateway functions during commissioning. The IS200RCSAG1A is critical for remote control management – ensure all settings are verified before placing in service. Ensure serial cabling does not exceed maximum recommended length. Regular verification of remote control and serial communication is recommended.

ABB AI723F
A-B 1747-ASB
ABB D685A1156U01
FOXBORO P0916GF


Reviews
There are no reviews yet.