| Parameter | Specification |
|---|---|
| Manufacturer | General Electric |
| Model | IS200LSGIH1APR1 |
| Load Shedding Functions | Load reduction coordination, priority-based shedding, emergency control (enhanced) |
| Gateway Functions | Data routing, protocol conversion, system coordination |
| Highway Interface | 2× bus highway ports (GE proprietary protocol) |
| Supported Protocols | GE highway, Modbus RTU, DNP3 |
| Protection Functions | Under-frequency load shedding, under-voltage protection coordination |
| Power | +5V DC / 2.0A, ±15V DC / 0.4A |
| Temp Range | -30°C to +65°C |
| MTBF | > 108,000 hours |
| Suffix Meaning | “APR1” = specific firmware/configuration with enhanced load shedding algorithms |
Advantages and Key Features
Enhanced Load Shedding and Gateway Interface: The IS200LSGIH1APR1 provides load shedding coordination with the “APR1” firmware configured for advanced shedding algorithms and protection features.
Advanced Load Shedding Logic: Improved priority-based shedding and emergency control.
Protection Coordination: The IS200LSGIH1APR1 coordinates under-frequency and under-voltage protection.
Gateway Communication: Integrates with distributed control and protection networks.
Pre-Configured Firmware: “APR1” firmware reduces commissioning time.
Application Fields and Case Studies
Used in advanced load shedding applications, emergency load reduction systems with enhanced logic, and grid disturbance management requiring sophisticated protection. In a 600 MW plant, the IS200LSGIH1APR1 provided enhanced load shedding coordination with advanced protection features.
Comparison with Competing Products
| Dimension | IS200LSGIH1APR1 | IS200LSGIH1APR | IS200ERBPG1ACA |
|---|---|---|---|
| Primary Function | Load shedding + gateway | Load shedding + gateway | Relay/breaker protection |
| Shedding Algorithms | Enhanced | Standard | No |
| VME Integration | Direct | Direct | Direct |
Selection Recommendations
Choose IS200LSGIH1APR1 when your load shedding application requires advanced shedding algorithms or enhanced protection features. Verify “APR1” firmware matches your specific load shedding and protection requirements before commissioning.
Precautions and Important Notes
Use ESD-safe handling. Verify field wiring and highway connections. Confirm “APR1” firmware supports your specific load shedding and protection requirements. Never interrupt firmware updates. Board draws 2.0A – verify rack power capacity. Document all configurations. Store spares in anti-static packaging. Do not mix IS200LSGIH1APR1 with IS200LSGIH1APR in redundant pairs without verifying identical firmware. Allow 30 seconds boot time. Test all load shedding and gateway functions during commissioning. If replacing an IS200LSGIH1APR with an IS200LSGIH1APR1, verify all protection configurations are compatible with the new firmware before installation. Ensure highway cabling does not exceed maximum recommended length. The IS200LSGIH1APR1 is critical for load shedding management – ensure all settings are verified before placing in service. Regular verification of load shedding and protection coordination is recommended.

ABB D674A906U01
ABB AX521
ABB IEPAS02
A-B 1784-PKTX


Reviews
There are no reviews yet.