Description
Technical Specifications
| Parameter | Specification |
|---|---|
| Manufacturer | General Electric |
| Model | IS200KSPAH1B |
| Keypad Interface | Local operator keypad port |
| Serial Port | 1× configurable serial port (RS-232 / RS-485) |
| Highway Interface | 2× bus highway ports (GE proprietary protocol) |
| Supported Protocols | GE highway, Modbus RTU, keypad protocols |
| Functions | Local control, configuration, diagnostics |
| Power | +5V DC / 2.0A, ±15V DC / 0.4A |
| Temp Range | -30°C to +65°C |
| MTBF | > 110,000 hours (improved “B” revision) |
| Revision Note | “B” suffix = improved hardware revision with enhanced reliability |
Advantages and Key Features
Dedicated Keypad and Serial Port Adapter Highway Interface: The IS200KSPAH1B provides local operator interface and highway communication.
Local Operator Interface: Keypad for local control, configuration, and diagnostics.
Serial Port Connectivity: Enables configuration and data exchange.
Improved Hardware Reliability: The “B” revision IS200KSPAH1B offers enhanced component specifications and noise immunity.
Highway Communication: Integrates with distributed control networks.
Application Fields and Case Studies
Used in local operator interface applications, keypad-based configuration and diagnostics, and highway-integrated local control systems. In a 600 MW plant, the IS200KSPAH1B provided reliable local operator interface and highway communication.
Comparison with Competing Products
| Dimension | IS200KSPAH1B | IS200JPDVG1A | IS200EBKPG1ACB |
|---|---|---|---|
| Primary Function | Keypad + serial + highway | Pulse data validation | Keyboard/programmer interface |
| Keypad Support | Yes | No | Yes |
| Serial Port | Yes | No | No |
| MTBF | > 110,000 hrs | > 108,000 hrs | > 120,000 hrs |
Selection Recommendations
Choose IS200KSPAH1B for local keypad operator interface and serial port connectivity with highway communication. Select the “B” revision for improved reliability. Verify compatibility with your keypad and serial devices.
Precautions and Important Notes
Use ESD-safe handling. Verify field wiring and keypad/serial connections. Confirm compatibility with your specific keypad and serial devices. Never interrupt firmware updates. Board draws 2.0A – verify rack power capacity. Document all configurations. Store spares in anti-static packaging. Do not mix IS200KSPAH1B with “A” revision boards in redundant pairs without verifying identical firmware. Allow 30 seconds boot time. Test all keypad, serial, and highway functions during commissioning. The IS200KSPAH1B is critical for local operator interface – ensure all settings are verified before placing in service. Ensure serial cabling does not exceed maximum recommended length. Regular verification of keypad and serial communication is recommended. The improved “B” hardware may require updated firmware in other system components for optimal compatibility.

GE IC200ALG264
FOXBORO FBM211
SIEMENS 6ES7315-2AG10-0AB0
ABB YPK112A