Description
Technical Specifications
| Parameter | Specification |
|---|---|
| Manufacturer | General Electric |
| Model | IS200JPDPG1A |
| Pulse Inputs | 4–8 pulse inputs (J-type, speed, flow, position sensors) |
| Data Protection | Pulse data validation, error checking, integrity monitoring |
| J-Type Gateway Functions | Data routing, protocol conversion, gateway communication |
| Supported Protocols | Modbus RTU, GE pulse protocols, J-type protocols |
| Communication | J-type serial interfaces, highway integration |
| Power | +5V DC / 2.0A, ±15V DC / 0.4A |
| Temp Range | -30°C to +65°C |
| MTBF | > 108,000 hours |
| Revision Note | “A” suffix = specific hardware/firmware configuration |
Advantages and Key Features
Dedicated J-Gateway Pulse Data Protection: The IS200JPDPG1A provides specialized pulse data protection and J-type gateway communication.
Data Protection Features: The IS200JPDPG1A handles validation, error checking, and integrity monitoring.
J-Type Gateway Functions: Enables data routing and protocol conversion.
Application Fields and Case Studies
Used in pulse data protection applications, J-type network integration with security requirements, and gateway communication for critical pulse data. In a 600 MW plant, the IS200JPDPG1A provided reliable pulse data protection and gateway communication.
Comparison with Competing Products
| Dimension | IS200JPDPG1A | IS200JPDMG1ADC | IS200JPDLG1ABC |
|---|---|---|---|
| Primary Function | Pulse data protection | Pulse data management | Pulse data logger |
| Data Protection | Yes | No | No |
| VME Integration | Direct | Direct | Direct |
Selection Recommendations
Choose IS200JPDPG1A for pulse data protection and J-type gateway applications. Verify compatibility with your specific pulse sensors and data protection requirements. Deploy for critical pulse data monitoring.
Precautions and Important Notes
Use ESD-safe handling. Verify field wiring and pulse connections. Confirm compatibility with your specific pulse sensors and data protection requirements. Never interrupt firmware updates. Board draws 2.0A – verify rack power capacity. Document all configurations. Store spares in anti-static packaging. Do not mix variants in redundant pairs. Allow 30 seconds boot time. Test all data protection and gateway functions during commissioning. The IS200JPDPG1A is critical for pulse data protection – ensure all settings are verified before placing in service. Ensure proper shielding for pulse signals to avoid noise interference. Regular verification of pulse data quality and protection performance is recommended. Ensure communication cabling does not exceed maximum recommended length.

A-B 1756-CNB
APC GES501W48V0180
FOXBORO FBM242
SIEMENS 6ES7332-5HF00-0AB0