Technical Specifications
| Parameter | Specification |
|---|---|
| Manufacturer | General Electric |
| Model | IS200ISBDG1A |
| Serial Bus Interfaces | 2× configurable serial ports (RS-232 / RS-485) |
| Data Gateway Functions | Serial data acquisition, data routing, protocol conversion |
| Supported Protocols | Modbus RTU, GE serial protocols, ASCII, data acquisition protocols |
| Communication Modes | Point-to-point, multi-drop |
| Power | +5V DC / 2.0A, ±15V DC / 0.4A |
| Temp Range | -30°C to +65°C |
| MTBF | > 108,000 hours |
| Revision Note | “A” suffix = specific hardware/firmware configuration |
Advantages and Key Features
Dedicated Serial Bus Data Gateway: The IS200ISBDG1A provides specialized data acquisition and gateway functions for serial bus devices.
Serial Data Acquisition: The IS200ISBDG1A collects data from serial devices for control system integration.
Protocol Conversion: Enables communication between serial devices and the Mark VI system.
Gateway Communication: Integrates serial data with control networks.
Application Fields and Case Studies
Used in serial data acquisition applications, gateway communication for serial devices, and integration of serial data with turbine control systems. In a 600 MW plant, the IS200ISBDG1A provided reliable serial data acquisition and gateway communication.
Comparison with Competing Products
| Dimension | IS200ISBDG1A | IS200ISBBG2A | IS200ISBAH1ABA |
|---|---|---|---|
| Primary Function | Serial data gateway | Serial bridge + gateway | Serial adapter + highway |
| Data Acquisition | Yes | No | No |
| VME Integration | Direct | Direct | Direct |
Selection Recommendations
Choose IS200ISBDG1A for serial data acquisition and gateway applications. Verify compatibility with your specific serial devices and data requirements. Deploy for serial data integration.
Precautions and Important Notes
Use ESD-safe handling. Verify field wiring and serial connections. Confirm compatibility with your specific serial devices and data requirements. Never interrupt firmware updates. Board draws 2.0A – verify rack power capacity. Document all configurations. Store spares in anti-static packaging. Do not mix variants in redundant pairs. Allow 30 seconds boot time. Test all data acquisition and gateway functions during commissioning. The IS200ISBDG1A is critical for serial data management – ensure all settings are verified before placing in service. Ensure serial cabling does not exceed maximum recommended length. Regular verification of serial communication and data acquisition performance is recommended.

MTL 8602-FT-ST
WESTINGHOUSE 1C31227G01
HONEYWELL CC-TAID11


Reviews