Description
Technical Specifications
| Parameter | Specification |
|---|---|
| Manufacturer | General Electric |
| Model | IS200EXTBG1AAA |
| Communication Interfaces | 2× configurable ports (RS-485 / fieldbus) |
| Supported Protocols | Modbus RTU, DNP3, IEC 61850, GE excitation protocols |
| Terminal Functions | Excitation terminal interface, protection coordination |
| Bridge Functions | Bridge status monitoring, coordination control |
| Supported Equipment | Excitation terminals, power bridges, protection relays |
| Power | +5V DC / 2.0A, ±15V DC / 0.4A |
| Temp Range | -30°C to +65°C |
| MTBF | > 110,000 hours |
| Suffix Meaning | “AAA” = specific terminal/bridge coordination configuration |
Advantages and Key Features
Dedicated Excitation Terminal and Bridge Gateway: The IS200EXTBG1AAA provides comprehensive interface for excitation terminal equipment and bridge coordination.
Terminal Protection Coordination: Enables coordination between excitation terminals and protection systems.
Bridge Status and Control: Provides bridge monitoring and coordination functions.
Multi-Protocol Support: Supports Modbus RTU, DNP3, and IEC 61850.
Pre-Configured Firmware: “AAA” firmware reduces commissioning time.
Application Fields and Case Studies
Used in excitation terminal interface and protection coordination, bridge status monitoring, and excitation system terminal equipment integration. In a 600 MW plant, the IS200EXTBG1AAA coordinated excitation terminals and bridge protection, ensuring reliable excitation system operation.
Comparison with Competing Products
| Dimension | IS200EXTBG1AAA | IS200EXIBG1AEB | IS200EXMDG1APR1 |
|---|---|---|---|
| Primary Function | Terminal + bridge coordination | Bridge interface | Diagnostics/monitoring |
| Terminal Protection | Yes | No | No |
| VME Integration | Direct | Direct | Direct |
Selection Recommendations
Choose IS200EXTBG1AAA for excitation terminal interface with bridge coordination. Verify “AAA” firmware matches your terminal and bridge equipment. Deploy redundant boards for critical coordination paths.
Precautions and Important Notes
Use ESD-safe handling. Verify communication wiring and settings. Confirm “AAA” firmware supports your specific terminal and bridge equipment. Never interrupt firmware updates. Board draws 2.0A – verify rack power capacity. Document all configurations. Store spares in anti-static packaging. Do not mix variants in redundant pairs. Allow 30 seconds boot time. Test all terminal and bridge coordination functions during commissioning. The IS200EXTBG1AAA is critical for excitation terminal coordination – ensure all protection and control functions are verified before placing in service.

GE UR6CH
A-B 845PY-FW-2-C/B
A-B 22B-D6P0N104
“BENTLY


Reviews
There are no reviews yet.