IS200ERBPG1ACA GE

¥999.00

The IS200ERBPG1ACA is an Enhanced Relay / Breaker Protection Gateway (ERBPG) Interface Board from GE’s Mark VI Speedtronic™ series, designed for protective relay coordination and breaker control in turbine generator systems. Unlike the power supply/motor focus of IS200EPSMG2AED or the transformer/converter functions of IS200EPCTG1AAA, the IS200ERBPG1ACA specializes in communication with protective relays, circuit breakers, and switchgear protection systems. The “ACA” suffix indicates a specific firmware configuration for protection relay and breaker coordination.

Category:

Description

Technical Specifications

Parameter Specification
Manufacturer General Electric
Model IS200ERBPG1ACA
Communication Interfaces 2× configurable ports (RS-485 / fieldbus)
Supported Protocols Modbus RTU, DNP3, IEC 61850, GE protection protocols
Protection Functions Relay coordination, breaker control, fault detection, event recording
Supported Equipment Protective relays, breakers, switchgear, fault recorders
Power +5V DC / 2.0A, ±15V DC / 0.4A
Temp Range -30°C to +65°C
MTBF > 110,000 hours
Suffix Meaning “ACA” = specific protection relay/breaker configuration

Advantages and Key Features

Dedicated Protection Gateway: The IS200ERBPG1ACA provides optimized communication with protective relays and breakers for coordinated generator and auxiliary protection.

Multi-Protocol Support: Supports Modbus RTU, DNP3, and IEC 61850 for substation integration.

Breaker Control: The IS200ERBPG1ACA enables remote breaker control and status monitoring.

Event Recording: Supports fault and event recording for post-event analysis.

Pre-Configured Firmware: “ACA” firmware reduces commissioning time.

Application Fields and Case Studies

Used in generator protection coordination, breaker control and monitoring, and fault event recording. In a 600 MW plant, the IS200ERBPG1ACA coordinated generator and transformer protection relays, enabling rapid fault isolation and event analysis.

Comparison with Competing Products

Dimension IS200ERBPG1ACA IS200EPCTG1AAA IS200EPBPG1AAC
Primary Function Relay/breaker protection Transformer/converter Power bus/protection
Breaker Control Yes No Yes
Protection Protocols DNP3, IEC 61850, Modbus DNP3, IEC 61850, Modbus DNP3, IEC 61850, Modbus
VME Integration Direct Direct Direct

Selection Recommendations

Choose IS200ERBPG1ACA for generator protection relay coordination, breaker control, and fault event recording. Verify “ACA” firmware matches your protection relays. Deploy redundant boards for critical protection paths.

Precautions and Important Notes

Use ESD-safe handling. Verify communication wiring and settings. Confirm “ACA” firmware supports your specific protective relays and breakers. Never interrupt firmware updates. Board draws 2.0A – verify rack power capacity. Document all configurations. Store spares in anti-static packaging. Do not mix variants in redundant pairs. Allow 30 seconds boot time. Test all protection coordination functions thoroughly during commissioning. The IS200ERBPG1ACA is critical for generator protection – ensure all relay settings and coordination schemes are verified before placing in service.

A-B 1756-PA75R
BALDOR BC154 CN3000A37
A-B 1746-NI8
A-B 1747-SN
FISHER ROSEMOUNT

Reviews

There are no reviews yet.

Be the first to review “IS200ERBPG1ACA GE”

Your email address will not be published. Required fields are marked *

Post comment