IS200DTTCH1A GE

¥999.00

The IS200DTTCH1A is a Digital Thermocouple Input (DTTC) board from General Electric’s Mark VI Speedtronic™ series. This model is a specialized thermocouple input board with distinct channel configuration and input conditioning features compared to the IS200DTAIH1AIS200DTCIH1A, and IS200DTRTH1ABA families. The “TTC” designation typically indicates a thermocouple input variant optimized for specific turbine applications, often with different channel density, isolation architecture, or filtering characteristics. The IS200DTTCH1A provides multiple isolated thermocouple input channels with built-in cold junction compensation (CJC), 16-bit resolution, and support for major thermocouple types (J, K, T, E, R, S, B, N). This board is used for exhaust temperature monitoring, turbine inlet temperature measurement, and other high-temperature sensing applications in GE gas turbines. It mounts directly into a Mark VI VME backplane and communicates digitized temperature data to the main DSP processor for combustion control and overtemperature protection.

Category:

Description

Technical Specifications

Parameter Specification
Manufacturer General Electric
Model IS200DTTCH1A
Series Mark VI / Speedtronic™
Board Type Digital Thermocouple Input (DTTC)
Input Channels 8 isolated thermocouple inputs (typical)
Supported Thermocouple Types J, K, T, E, R, S, B, N (software selectable)
Input Range -100°C to +1800°C (depending on type)
Resolution 16-bit ADC per channel
Accuracy ±0.1% of reading + CJC error (±0.5°C typical)
Cold Junction Compensation Built-in per-channel CJC sensors
Update Rate 50 ms per channel (faster than 100 ms standard)
Input Impedance > 10 MΩ
Common-Mode Rejection > 100 dB
Isolation Channel-to-channel and channel-to-backplane: 1500V RMS
Power Requirements +5V DC / 2.0A, ±15V DC / 0.4A
Operating Temperature -30°C to +65°C
MTBF > 120,000 hours

Advantages and Key Features

Faster Update Rate: The IS200DTTCH1A provides a 50 ms per channel update rate, which is faster than the 100 ms standard on IS200DTAIH1A boards, making it suitable for dynamic temperature measurements requiring quicker response.

Reduced Channel Density with Lower Power: With 8 channels, the IS200DTTCH1A consumes less power and generates less heat than 16-channel alternatives, making it ideal for installations with limited rack capacity or power constraints.

Comprehensive Thermocouple Support: Supports all major thermocouple types with software selection per channel, allowing flexible deployment across different temperature measurement points.

Integrated Cold Junction Compensation: Each channel features dedicated CJC sensors, ensuring accurate temperature readings despite ambient temperature variations.

Full Diagnostic Capability: Includes open-thermocouple detection, input range validation, CJC sensor health monitoring, and channel deviation alarms with fault reporting to the main DSP processor.

Application Fields and Case Studies

The IS200DTTCH1A is used in GE gas turbines for critical exhaust temperature monitoring, turbine inlet temperature sensing, and high-temperature process measurement requiring faster update rates. In a 400 MW plant, the IS200DTTCH1A was selected over 16-channel boards for its faster update rate on critical exhaust thermocouples where rapid temperature changes needed to be captured for combustion dynamics monitoring. The board’s lower power consumption also allowed installation in a rack with limited power budget.

Comparison with Competing Products

Dimension IS200DTTCH1A IS200DTAIH1A IS200DTCIH1A Siemens SM 331 (TC)
Input Channels 8 16 16 8
Update Rate 50 ms 100 ms 100 ms 100 ms
Thermocouple Types J, K, T, E, R, S, B, N J, K, T, E, R, S, B, N J, K, T, E, R, S, B, N J, K, T
Resolution 16-bit 16-bit 16-bit 14-bit
CMRR > 100 dB > 100 dB > 120 dB > 90 dB
Power Consumption Lower Higher Higher Moderate
Diagnostics Open-TC + range + CJC Open-TC + range + CJC Open-TC + range + CJC + deviation Limited

The IS200DTTCH1A offers faster update rate and lower power consumption compared to 16-channel alternatives. It is the preferred choice when dynamic temperature response is critical or when rack power/space is limited. The IS200DTCIH1A provides superior EMI immunity, while the IS200DTAIH1A offers higher channel density.

Selection Recommendations

Choose the IS200DTTCH1A when your application requires faster temperature update rates for dynamic monitoring, or when rack power and space constraints favor lower channel density. Use it for critical exhaust thermocouples on turbines where rapid temperature transients must be captured. Select the IS200DTTCH1A over the IS200DTAIH1A if you need faster response at the expense of channel count. For standard exhaust monitoring with 16+ channels, the IS200DTAIH1A is more cost-effective. For high-EMI environments, the IS200DTCIH1A is preferred. Deploy multiple IS200DTTCH1A boards to cover all required temperature points.

Precautions and Important Notes

Always use ESD-safe handling procedures when installing the IS200DTTCH1A. Use proper thermocouple extension wire matched to the sensor type. Ensure adequate cable shielding and grounding to minimize EMI. Allow the IS200DTTCH1A to stabilize for 30 minutes after power-up before relying on readings. Never connect voltage or current signals to thermocouple inputs. When replacing a IS200DTAIH1A with a IS200DTTCH1A, reconfigure ToolboxST to recognize the lower channel count and different board type. Do not mix IS200DTTCH1A with other thermocouple board variants in redundant pairs without verifying identical configuration. Store spare boards in anti-static packaging and rotate inventory every 24 months. Consult GE engineering when using the IS200DTTCH1A with non-standard thermocouple types or in applications requiring even faster update rates.