Description
Technical Specifications
| Parameter | Specification |
|---|---|
| Manufacturer | General Electric |
| Model | IS200DSVOH1ABA |
| Series | Mark VI / Speedtronic™ |
| Board Type | Digital Signal Voltage Output (DSVO) |
| Output Channels | 8 isolated analog voltage outputs |
| Output Range | ±10V DC or 0–10V DC (software configurable) |
| Resolution | 16-bit DAC per channel |
| Accuracy | ±0.1% of full scale (typical) |
| Update Rate | 1 ms per channel (sequential) |
| Output Current Capability | ±10 mA per channel (short-circuit protected) |
| Isolation | Channel-to-channel and channel-to-backplane: 1500V RMS |
| Power Requirements | +5V DC / 2.0A, ±15V DC / 0.5A |
| Operating Temperature | -30°C to +65°C |
| Suffix Meaning | “ABA” = specific firmware/configuration variant |
Advantages and Key Features
Reduced Commissioning Time: The IS200DSVOH1ABA ships with factory-preloaded actuator configuration parameters, eliminating manual scaling and range setup for common GE valve actuators.
High-Resolution Actuator Control: Each of the 8 channels on the IS200DSVOH1ABA utilizes 16-bit DACs, providing exceptional precision for fuel valve and IGV positioning.
Complete Channel Isolation: Galvanic isolation of 1500V RMS per channel prevents ground loops and ensures reliable operation in electrically noisy turbine environments.
Individual Channel Diagnostics: The IS200DSVOH1ABA features per-channel fault detection including open-circuit, short-circuit, and output deviation monitoring, reported to the main DSP processor for immediate protective action.
Redundancy-Ready: Dual IS200DSVOH1ABA boards can be configured for automatic failover, ensuring uninterrupted actuator control upon fault detection.
Application Fields and Case Studies
The IS200DSVOH1ABA is used in GE Frame 6B/7E/9E gas turbine fuel valve control, steam turbine admission valve positioning, compressor IGV actuation, and industrial process valve control. In a North American 600 MW combined-cycle plant, the IS200DSVOH1ABA was selected for its factory-preloaded configuration matching the site’s specific electro-hydraulic actuators, reducing commissioning time by 4 hours per board. When a field wiring fault caused a short circuit on one channel, the IS200DSVOH1ABA diagnostics immediately isolated the fault and alerted the main IS200DSPXH2DBD processor.
Comparison with Competing Products
| Dimension | IS200DSVOH1ABA | Siemens SM 332 | Woodward AOV-8 | ABB AO810 |
|---|---|---|---|---|
| Output Channels | 8 | 8 | 4 | 8 |
| Resolution | 16-bit | 14-bit | 12-bit | 16-bit |
| Isolation | 1500V RMS per channel | 500V RMS | 1000V RMS | 1500V RMS |
| Update Rate | 1 ms | 2 ms | 5 ms | 1 ms |
| Pre-configured Options | Yes (ABA) | Limited | No | Limited |
| Diagnostics | Per-channel fault detection | Limited | None | Per-channel detection |
The IS200DSVOH1ABA offers superior isolation, faster update rates, and valuable factory pre-configuration. The “ABA” variant provides a clear advantage over generic IS200DSVOH1A boards when deploying standardized actuator packages, reducing setup time and configuration errors.
Selection Recommendations
Select the IS200DSVOH1ABA when your project involves GE actuators with factory-matched parameters, as the preloaded configuration accelerates commissioning. Use it as a replacement for IS200DSVOH1A or IS200DSVOH1B boards with full compatibility. Deploy redundant IS200DSVOH1ABA boards for critical fuel valve control to ensure single-fault tolerance. Avoid the IS200DSVOH1ABA if your actuator requires non-standard scaling not covered by the preload; instead use a blank IS200DSVOH1A and configure manually. Verify actuator compatibility before ordering, as the “ABA” preload may be specific to certain actuator models.
Precautions and Important Notes
Always use ESD-safe handling procedures when installing the IS200DSVOH1ABA. Never connect outputs to current-loop devices without proper signal conditioning. Verify that the preloaded “ABA” configuration matches your specific actuator scaling; incorrect parameters can cause unsafe valve positioning. Ensure +5V and ±15V power supplies are within tolerance for accurate output. Document all channel-to-actuator wiring mappings before board replacement. Do not mix IS200DSVOH1ABA with standard IS200DSVOH1A boards in redundant pairs without verifying identical configuration settings. Store spare boards in anti-static packaging and rotate inventory every 24 months. Consult GE engineering if repurposing the IS200DSVOH1ABA for non-standard actuator types.

FOXBORO P0916JP
A-B 1794-IR8/A
A-B 1746-NO4I
FOXBORO FBM214


Reviews