IS200ATBAG1A GE

¥999.00

The IS200ATBAG1A is a Mark VIe Analog Termination / Breakout and Application Gateway Module manufactured by GE (now Emerson) for the Speedtronic™ Mark V and Mark VIe turbine control systems. The “ATBAG1” designation indicates a module designed for analog signal termination, breakout distribution, and application gateway functions, providing high-accuracy analog signal conditioning and distribution with integrated application processing for specialized monitoring and control tasks. The “A” suffix denotes a specific hardware revision and firmware configuration optimized for the Mark VIe platform.

The IS200ATBAG1A functions as a high-precision analog termination and breakout module, providing signal conditioning, distribution, and application processing for analog field devices. It is designed for applications requiring organized analog signal termination, breakout functionality for field wiring, and localized processing for specialized monitoring and control tasks.

Category:

Description

Key Technical Parameters

Parameter Specification
Brand GE / Emerson
Model IS200ATBAG1A
Analog Input Terminals 16 channels, configurable for 4–20 mA, 0–10 V, or thermocouple (J, K, T, E, R, S)
Analog Output Terminals 8 channels, configurable for 4–20 mA or 0–10 V
Breakout Distribution Integrated breakout for field wiring termination
Signal Conditioning Programmable filtering, averaging, scaling, and offset compensation
Input Impedance 250 Ω (current), >1 MΩ (voltage)
Output Drive 750 Ω max (current), >2 kΩ min (voltage)
Resolution 20-bit (inputs), 16-bit (outputs)
Accuracy ±0.02% of full scale (inputs), ±0.05% of full scale (outputs)
Application Processing Advanced logic and calculation functions (C/IEC 61131-3)
Isolation Channel-to-channel and channel-to-ground (1500 VAC)
Cold Junction Compensation Built-in with redundant reference sensors
Protection Overvoltage, reverse polarity, short-circuit (outputs), input burnout detection, transient suppression
Diagnostics Input burnout detection, output short/open detection, communication status, self-test routines
Communication Fiber-optic (Mark V/VIe backplane)
Cooling Passive – no fan
Dimensions 260 × 180 × 35 mm (standard Eurocard)
Operating Temp –20°C to +65°C
Certifications CE, UL, CSA, ATEX (Class I, Div 2), IEC 61508 SIL-1

Advantages & Features

  • High-Density Analog Termination – The IS200ATBAG1A provides 16 analog input terminals and 8 analog output terminals in a single module, maximizing channel density for large-scale monitoring and control applications.

  • Integrated Breakout Distribution – Built-in breakout for field wiring termination simplifies cabling and reduces installation complexity.

  • Universal Inputs – Supports 4–20 mA, 0–10 V, and thermocouple (J, K, T, E, R, S) inputs, eliminating the need for multiple specialized modules.

  • High Accuracy – 20-bit input resolution with ±0.02% accuracy ensures the highest precision process measurement.

  • Application Processing – Supports advanced logic and calculation functions (C/IEC 61131-3) for localized monitoring, control, and analytics.

  • Thermocouple Support – Built-in cold junction compensation with redundant reference sensors and linearization for six thermocouple types.

  • Signal Conditioning – Programmable filtering, averaging, scaling, and offset compensation for optimized signal processing.

  • Input Burnout Detection – Detects open-circuit conditions on 4–20 mA and thermocouple inputs, enabling rapid identification of sensor faults.

  • High Isolation – 1500 VAC channel-to-channel and channel-to-ground isolation protects the module and controller.

  • Extended Temperature Range – Rated for –20°C to +65°C, suitable for harsh environmental conditions.

  • Fiber-Optic Backplane – Interfaces with the Mark V/VIe controller via high-speed fiber-optic backplane, ensuring noise-immune data transmission.

  • Hot-Swap Capable – Supports live insertion/removal with safety interlocks, minimizing downtime.

  • High Reliability – Military-grade components, conformal-coated PCB, and robust design with MTBF of 90,000 hours.

Application Cases

  • Process Variable Monitoring – Terminates and processes signals from 16 analog sensors (pressure transmitters, temperature sensors, flow meters) for comprehensive turbine monitoring.

  • Actuator Control – 8 analog outputs control fuel valves, IGV positioners, and other final control elements.

  • Exhaust Temperature Monitoring – Direct thermocouple inputs (J, K, T, E, R, S) for EGT monitoring.

  • Field Wiring Termination – Breakout distribution simplifies field wiring and reduces installation time.

  • Localized Processing – Performs advanced calculations and logic functions locally, offloading the main controller.

  • Harsh Environment Installations – Extended –20°C to +65°C range makes it suitable for demanding installations.

  • Retrofit Projects – Replaces multiple legacy analog modules while providing integrated termination and breakout.

Comparison with Competitor Products

Feature GE IS200ATBAG1A GE IS200AEPAH1AAA Siemens S7-1500 (AI/AO + Breakout) ABB AC800M (AI/AO + Termination)
Analog Inputs 16 (universal) 8 (universal) 16 16
Analog Outputs 8 4 8 8
Breakout Distribution Yes No Yes (external) Yes (external)
Thermocouple Types J, K, T, E, R, S J, K, T, E, R, S J, K, T J, K, T
Input Resolution 20-bit 20-bit 16-bit 16-bit
Accuracy ±0.02% ±0.02% ±0.1% ±0.1%
Application Processing Yes Yes Yes Yes
Isolation 1500 VAC 1500 VAC 500 VAC 500 VAC
Operating Temp –20°C to +65°C –20°C to +65°C 0°C to +60°C 0°C to +55°C
Hot-Swap Yes Yes No No
MTBF 90,000 hrs 88,000 hrs 85,000 hrs 80,000 hrs

Key Differentiator: The IS200ATBAG1A uniquely combines high-density universal analog inputs (16 channels), high-accuracy analog outputs (8 channels), integrated breakout distribution for field wiring, and application processing, making it the most comprehensive analog termination and breakout module for GE Mark V/VIe systems.

Selection Suggestions

  1. Evaluate Analog I/O and Termination Requirements – The IS200ATBAG1A is ideal for applications requiring high-channel-count analog I/O with integrated termination and breakout distribution.

  2. Identify Thermocouple Needs – Supports J, K, T, E, R, S thermocouples; verify your sensor types.

  3. Consider Environment – Extended –20°C to +65°C range makes it suitable for harsh environments.

  4. Breakout Distribution – Use the integrated breakout for simplified field wiring and reduced installation time.

  5. Application Processing – Use for advanced localized monitoring, control, and analytics to offload the main controller.

  6. Firmware – The “A” suffix indicates a specific firmware version; verify compatibility with your Mark V/VIe system.

  7. Spares – Lead time typically 8–10 weeks; maintain a spare module for critical installations.

Precautions

  • ESD Protection – Use wrist strap and anti-static handling during installation.

  • Analog Input Wiring – Use shielded twisted-pair cables; ground shields at the module end only.

  • Thermocouple Wiring – Use thermocouple-grade extension wire of the same type; avoid copper wire between sensor and module.

  • Breakout Wiring – Ensure proper wiring termination at the breakout section; verify connections before applying power.

  • Cold Junction Compensation – Ensure cold junction sensors are protected from external heat sources or drafts.

  • Analog Output Wiring – For 4–20 mA outputs, ensure the loop resistance is within the module’s drive capability (750 Ω max).

  • Avoid Ground Loops – Connect earth lug directly to system ground with 6 mm² wire; avoid ground loops.

  • Input Burnout Detection – Configure burnout detection for 4–20 mA and thermocouple inputs.

  • Commissioning – Verify input readings with known signal sources and test outputs with dummy loads before field connection.

  • Firmware Updates – Use only GE’s official tool for firmware updates.

  • Periodic Inspection – Check for dust accumulation on heatsink and connector integrity annually; clean as needed.

Summary

The IS200ATBAG1A is a comprehensive analog termination, breakout, and application module for GE Speedtronic Mark V and Mark VIe turbine control systems, providing high-density universal analog inputs, analog outputs, integrated breakout distribution, and application processing. Its key strengths include 16 universal analog inputs (4–20 mA, 0–10 V, thermocouple J/K/T/E/R/S), 8 analog outputs (4–20 mA/0–10 V), 20-bit input resolution with ±0.02% accuracy, integrated breakout distribution for field wiring, advanced application processing (C/IEC 61131-3), built-in cold junction compensation with redundant sensors, 1500 VAC isolationinput burnout detectionextended –20°C to +65°C operating rangefiber-optic backplanehot-swap capability, and MTBF of 90,000 hours. Ideal for process variable monitoring, actuator control, exhaust temperature monitoring, field wiring termination, localized processing, harsh environment installations, and retrofit projects, it provides the most comprehensive analog I/O with integrated breakout and processing functionality for Mark V/VIe systems. When paired with the Mark V/VIe controller and properly maintained, the IS200ATBAG1A delivers decades of reliable, precise, and termination-ready analog I/O and processing service in demanding environments.

HONEYWELL CC-PAON01
EMERSON CE4001S2T2B4
WESTINGHOUSE 5X00106G01

Reviews

There are no reviews yet.

Be the first to review “IS200ATBAG1A GE”

Your email address will not be published. Required fields are marked *

Post comment