HONEYWELL TDIL01

¥5,299.00

Detailed Product Parameters

  • Product Type: Digital Input Isolator Module (Point Module).

  • Compatibility: Designed for use with Honeywell Experion PKS C200, C200E, C300, and ACE controllers. Also compatible with PlantScape systems.

  • Isolation Rating: Provides high-grade galvanic isolation between field wiring and the control system’s internal electronics.

  • Input Channels: Typically configurable for multiple dry contact or wet digital input signals (e.g., from switches, relays, proximity sensors).

  • Voltage Ratings: Supports a range of field input voltages (e.g., 24V DC, 120V AC). Specifics depend on the exact module configuration and wiring.

  • Mounting: Installs into a dedicated I/O module carrier or baseplate within the Honeywell control enclosure.

  • Diagnostics: Often includes LED status indicators for channel activity and fault detection.

  • Communication: Interfaces directly with the controller’s I/O network (e.g., via FTA or similar bus).

Category:

Description

Product Overview: The HONEYWELL TDIL01 Isolator Module

The HONEYWELL TDIL01 is a critical interface and signal conditioning module designed for use in industrial control and automation systems, particularly those within the Experion PKS and PlantScape platforms. Its primary function is to provide electrical isolation between field devices and the controller’s I/O cards. This isolation protects sensitive control system components from potentially damaging voltages, currents, and electrical noise present in harsh industrial environments. By ensuring clean and reliable signal transmission, the HONEYWELL TDIL01 module is essential for maintaining system integrity, accuracy, and safety. You can find detailed specifications for this robust isolator on the official product page: HONEYWELL TDIL01.

Detailed Product Parameters

  • Product Type: Digital Input Isolator Module (Point Module).

  • Compatibility: Designed for use with Honeywell Experion PKS C200, C200E, C300, and ACE controllers. Also compatible with PlantScape systems.

  • Isolation Rating: Provides high-grade galvanic isolation between field wiring and the control system’s internal electronics.

  • Input Channels: Typically configurable for multiple dry contact or wet digital input signals (e.g., from switches, relays, proximity sensors).

  • Voltage Ratings: Supports a range of field input voltages (e.g., 24V DC, 120V AC). Specifics depend on the exact module configuration and wiring.

  • Mounting: Installs into a dedicated I/O module carrier or baseplate within the Honeywell control enclosure.

  • Diagnostics: Often includes LED status indicators for channel activity and fault detection.

  • Communication: Interfaces directly with the controller’s I/O network (e.g., via FTA or similar bus).

Key Advantages and Distinguishing Features

The HONEYWELL TDIL01 offers several benefits that make it a preferred choice for system integrators. Its foremost advantage is the robust electrical isolation, which prevents ground loops and noise from corrupting signal data, thereby drastically improving measurement accuracy and system reliability. The module is engineered for high density, allowing many I/O points to be consolidated in a small footprint, which optimizes cabinet space. As a component of the Experion ecosystem, it enables seamless integration, simplified configuration through control software, and reliable performance backed by Honeywell’s global support network. The design prioritizes durability to operate in demanding conditions with wide temperature ranges and high EMI immunity.

Typical Applications and Use Cases

This isolator module is deployed across a vast array of industries where reliable digital signal acquisition is paramount. In oil and gas production facilities, the HONEYWELL TDIL01 is used to isolate signals from emergency shutdown (ESD) valves and critical pressure switches. Within pharmaceutical manufacturing, it ensures the precise reading of batch process status from interlocks and safety gates. Power generation plants utilize it to connect turbine and boiler status contacts, while water treatment facilities rely on it for pump run feedback and level switch inputs. Any application within a Honeywell DCS environment requiring protected acquisition of discrete field device states is a candidate for this module.

Comparison with Competing I/O Modules

Compared to generic third-party isolators or basic PLC input cards, the TDIL01 is purpose-built for deep integration with Honeywell’s Experion architecture. While universal signal conditioners may offer similar isolation, they lack the native diagnostic communication, hot-swap capability (in supported configurations), and unified engineering environment that the Honeywell solution provides. Against other DCS vendor I/O, Honeywell’s point-level modularity, such as that offered by the HONEYWELL TDIL01, often allows for more granular sparing and easier maintenance compared to larger, multi-channel boards, potentially reducing long-term lifecycle costs.

Selection Guidelines and Important Considerations

When selecting this module, verify the exact part number and series to ensure compatibility with your existing controller (C200, C300, etc.) and I/O carrier. Always confirm the required field input type (dry contact vs. voltage sourcing) and voltage level. Consider the total number of digital input points needed in a rack to plan the quantity of TDIL01 modules required. It is crucial to follow Honeywell’s installation guidelines, including proper grounding and segregation of field wiring, to achieve the specified isolation performance. For legacy system upgrades or expansions, consulting the latest Honeywell technical notes or a certified distributor for the HONEYWELL TDIL01 is highly recommended to confirm interoperability.

TDIL01

FIFEOI-BPN.202230-001M277016 PLC
1398-DDM-019
A16B1200-0720/06A
HAMAMATSU-MVS-7000 PLC
1756-IRT8I
6SC9811-4DA04
3500/32M PLC
3500/53 PLC
1FK7063-5AF71-1SA0 PLC

Reviews

There are no reviews yet.

Be the first to review “HONEYWELL TDIL01”

Your email address will not be published. Required fields are marked *

Post comment