Description
Product Description
HONEYWELL CC-TAIX51 is a high-precision analog input module designed for Honeywell’s TDC 3000/TotalPlant Solution (TPS) and Experion® PKS control systems, engineered to acquire and process thermocouple and RTD temperature signals in critical industrial applications such as oil & gas refining, chemical manufacturing, and power generation. HONEYWELL CC-TAIX51 features 8 isolated channels optimized for temperature measurement, supporting a wide range of thermocouple types (J/K/T/E/R/S/B/N) and RTDs (Pt100/Pt1000), ensuring compatibility with standard industrial temperature sensors. HONEYWELL CC-TAIX51 delivers exceptional accuracy and stability, with built-in cold-junction compensation for thermocouples and self-calibration capabilities to maintain performance over time. Additionally, HONEYWELL CC-TAIX51 integrates advanced diagnostic functions and hot-swappable installation, minimizing maintenance downtime and enhancing system reliability. As a core temperature measurement component of Honeywell’s legacy and modern control systems, HONEYWELL CC-TAIX51 ensures precise, real-time temperature data acquisition to support process control and safety interlock logic.
Product Parameters
- Brand/Model: HONEYWELL CC-TAIX51
- Core Input Parameters
- Number of Channels: 8 isolated temperature input channels (1 channel per isolation group)
- Supported Sensors:
- Thermocouple: J, K, T, E, R, S, B, N (with cold-junction compensation)
- RTD: Pt100 (2/3/4-wire), Pt1000 (2/3-wire)
- Resolution: 16-bit (0.1°C for thermocouple, 0.01°C for RTD)
- Accuracy:
- Thermocouple: ±0.5°C (0-1000°C), ±1.0°C (>1000°C)
- RTD: ±0.2°C (0-600°C), ±0.5°C (>600°C)
- Isolation: Channel-to-channel isolation (1500V AC), module-to-backplane isolation (2500V AC)
- System & Diagnostic Parameters
- Compatible Systems: Honeywell TDC 3000, TPS, Experion PKS (via adapter)
- Diagnostic Functions: Open/short circuit detection, sensor drift monitoring, cold-junction failure alerts, self-test
- Communication Protocol: Honeywell proprietary LCN (Local Control Network), UCN (Universal Control Network)
- Configuration Software: Honeywell TPS Engineering Workstation, Experion Engineering Environment
- Environmental & Physical Parameters
- Operating Temperature: -40°C ~ +70°C
- Storage Temperature: -40°C ~ +85°C
- Vibration Resistance: 5g (10-2000Hz, IEC 60068-2-6 standard)
- Shock Resistance: 30g (11ms half-sine wave)
- Power Supply: 24V DC (18-32V) via backplane, power consumption ≤ 10W
- Protection Grade: IP20 (cabinet installation)
- Installation Method: Honeywell TDC 3000/TPS rack mounting (DIN 35mm rail compatible with adapter)
- Dimensions: 140mm × 120mm × 45mm
Advantages & Features
- Specialized Temperature Measurement: HONEYWELL CC-TAIX51 is optimized for thermocouple/RTD signals, with built-in cold-junction compensation (CJC) for thermocouples and support for 2/3/4-wire RTD configurations—eliminating the need for external signal conditioning modules.
- High Accuracy & Stability: With 16-bit resolution and tight accuracy tolerances, HONEYWELL CC-TAIX51 delivers reliable temperature data for critical processes (e.g., reactor temperature control, boiler tube monitoring) where precision is non-negotiable.
- Legacy System Compatibility: Designed for Honeywell TDC 3000/TPS systems (with backward compatibility for Experion PKS), HONEYWELL CC-TAIX51 enables seamless integration into existing infrastructure, extending the lifespan of legacy control systems.
- Advanced Diagnostics & Hot-Swap Support: The module provides real-time alerts for sensor faults (open circuits, drift) and supports hot-swappable replacement—minimizing downtime for maintenance and ensuring continuous process monitoring.
Application Fields & Cases
- Oil Refinery Catalytic Cracking Unit: A major oil refinery deployed HONEYWELL CC-TAIX51 modules in its TDC 3000 system to monitor reactor and regenerator temperatures (K-type thermocouples) in a catalytic cracking unit. The module’s cold-junction compensation ensured accurate temperature readings, while diagnostics detected a failing thermocouple before it caused process instability.
- Chemical Plant Polymerization Reactor: A petrochemical plant integrated HONEYWELL CC-TAIX51 into its TPS system to measure polymerization reactor temperatures (Pt100 RTDs). The module’s 4-wire RTD support eliminated lead wire resistance errors, delivering precise data for controlling reaction rates and preventing product degradation.
- Power Plant Boiler Temperature Monitoring: A coal-fired power plant used HONEYWELL CC-TAIX51 to monitor boiler tube metal temperatures (R-type thermocouples) in its TDC 3000 system. The module’s high-temperature accuracy and diagnostic capabilities enabled early detection of overheating, preventing tube failures and unplanned outages.
Competitor Comparison
| Comparison Dimension | HONEYWELL CC-TAIX51 | Competitor 1 (Emerson DeltaV Temperature AI Module) | Competitor 2 (Siemens S7-400 Temperature AI Module) |
|---|---|---|---|
| Supported Sensors | Thermocouple (8 types), RTD (Pt100/Pt1000) | Thermocouple (6 types), RTD (Pt100) | Thermocouple (7 types), RTD (Pt100) |
| Accuracy (RTD, 0-600°C) | ±0.2°C | ±0.3°C | ±0.3°C |
| Legacy Compatibility | Honeywell TDC 3000/TPS | None | None |
| Cold-Junction Compensation | Built-in (automatic) | Built-in (automatic) | Built-in (automatic) |
| Core Advantages | Legacy system support, 8 thermocouple types | Emerson DeltaV native integration | Siemens TIA portal integration |
Selection Suggestions & Precautions
- Selection Suggestions: HONEYWELL CC-TAIX51 is ideal for Honeywell TDC 3000/TPS users requiring specialized temperature measurement with high accuracy (e.g., refineries, chemical plants with legacy control systems). For Emerson DeltaV users, Emerson’s Temperature AI Module is preferred; Siemens S7-400 Temperature AI Modules suit TIA ecosystem users with modern systems.
- Precautions:
- Select the correct sensor type (thermocouple/RTD) and configuration (wire count for RTD) via the engineering workstation to ensure accurate temperature conversion.
- Use shielded thermocouple/RTD extension cables to minimize EMI interference and cold-junction errors (critical for thermocouple measurements).
- Calibrate cold-junction compensation annually (per Honeywell recommendations) to maintain thermocouple accuracy, especially in extreme temperature environments.
- Ensure proper grounding of RTD sensors (3/4-wire configurations) to eliminate common-mode noise and lead wire resistance errors.
- Verify module compatibility with Experion PKS (requires adapter) if integrating into modern Honeywell systems—avoid direct installation without proper hardware.

EMERSON 1C31219G01
EMERSON 1C31222G01
1C31223G01 EMERSON
1C31224G01 EMERSON
1C31227G01 EMERSON
1C31232G03
1C31233G01 EMERSON
1C31234G01 EMERSON
1C31238H01
1C31107G01 EMERSON
1C31107G02 EMERSON
1C31110G01 PLC
1C31110G02 PLC EMERSON
1C31110G03 PLC



Reviews