HONEYWELL 8C-PAINA1

¥999.00

HONEYWELL 8C-PAINA1 is a high-performance analog input module designed for Honeywell’s ControlEdge™ PLC and Experion® PKS systems, specializing in precise acquisition of industrial analog signals (4-20mA, 0-10V) for critical process control and monitoring. As a key component of Honeywell’s industrial automation portfolio, HONEYWELL 8C-PAINA1 delivers reliable, high-resolution data from sensors (pressure, temperature, flow) to central control systems, making it ideal for oil & gas, petrochemical, pharmaceutical, and water treatment industries. In a refinery’s distillation column control, HONEYWELL 8C-PAINA1 captures real-time temperature and pressure data; in a pharmaceutical manufacturing plant, HONEYWELL 8C-PAINA1 monitors batch reactor process parameters; in a municipal water treatment facility, HONEYWELL 8C-PAINA1 acquires flow rate and chemical dosing signals. Additionally, HONEYWELL 8C-PAINA1 features isolated channels, redundant power support, and advanced diagnostics, ensuring uninterrupted operation and simplified maintenance in 24/7 industrial environments.

Category:

Description

1. Product Overview

HONEYWELL 8C-PAINA1 is a high-performance analog input module designed for Honeywell’s ControlEdge™ PLC and Experion® PKS systems, specializing in precise acquisition of industrial analog signals (4-20mA, 0-10V) for critical process control and monitoring. As a key component of Honeywell’s industrial automation portfolio, HONEYWELL 8C-PAINA1 delivers reliable, high-resolution data from sensors (pressure, temperature, flow) to central control systems, making it ideal for oil & gas, petrochemical, pharmaceutical, and water treatment industries. In a refinery’s distillation column control, HONEYWELL 8C-PAINA1 captures real-time temperature and pressure data; in a pharmaceutical manufacturing plant, HONEYWELL 8C-PAINA1 monitors batch reactor process parameters; in a municipal water treatment facility, HONEYWELL 8C-PAINA1 acquires flow rate and chemical dosing signals. Additionally, HONEYWELL 8C-PAINA1 features isolated channels, redundant power support, and advanced diagnostics, ensuring uninterrupted operation and simplified maintenance in 24/7 industrial environments.

2. Product Parameters

2.1 Core Input Specifications

  • Input Channels: 8 differential analog input channels (independently configurable)
  • Supported Signals: 4-20mA (loop-powered/sourcing), 0-10V DC, ±10V DC, 0-5V DC
  • Resolution: 16-bit (high-precision data capture)
  • Accuracy: ±0.05% of full scale (calibrated over 0-55°C)
  • Isolation Rating: 2500V AC channel-to-channel, channel-to-ground, and channel-to-power
  • Sampling Rate: 100 samples per second (per channel) for real-time data acquisition
  • Input Impedance: 1MΩ (voltage inputs), 250Ω (current inputs)

2.2 Electrical & System Parameters

  • Power Supply: 24V DC (redundant inputs supported), power consumption ≤12W
  • Compatibility: Honeywell ControlEdge PLC, Experion PKS, third-party SCADA/DCS via Modbus TCP
  • Communication Interface: Ethernet/IP, Modbus TCP (integrated with system bus)
  • Diagnostic Features: Open-loop detection (current inputs), overrange/underrange alerts, short-circuit protection, module self-test, LED status indicators (power, fault, channel status)
  • Configuration: Software-configurable via Honeywell’s Control Builder or Experion Configuration Studio

2.3 Environmental & Mechanical Parameters

  • Operating Temperature: -40°C to +70°C (broad industrial range for extreme conditions)
  • Storage Temperature: -40°C to +85°C
  • Relative Humidity: 5% to 95% (non-condensing), resistant to humidity fluctuations
  • Vibration Resistance: 5-500Hz, 2g (IEC 60068-2-6)
  • Shock Resistance: 30g (11ms, IEC 60068-2-27)
  • Mounting: DIN rail-mounted (35mm standard), compact form factor
  • Dimensions: 120mm (W) × 100mm (H) × 60mm (D), space-efficient design for control cabinets
  • Protection: Conformally coated PCB for dust and moisture resistance (optional)

2.4 Certifications & Compliance

  • Safety Certifications: SIL 2 (IEC 61508/61511) for safety-related applications
  • Industry Certifications: CE, UL/cUL Class 1 Div 2, ATEX Zone 2, FCC Part 15, RoHS
  • Reliability: MTBF ≥ 1,200,000 hours (per Telcordia SR-332 standards)

3. Advantages & Features

  1. High-Precision Data Acquisition: 16-bit resolution and ±0.05% accuracy of HONEYWELL 8C-PAINA1 ensure reliable, repeatable measurements for critical process control, reducing variability and improving product quality.
  2. Comprehensive Isolation: 2500V AC isolation between channels, ground, and power protects HONEYWELL 8C-PAINA1 from electrical interference and surge damage, minimizing downtime in noisy industrial environments.
  3. Redundant Power Support: Dual 24V DC input capability ensures uninterrupted operation of HONEYWELL 8C-PAINA1 even if one power source fails, critical for mission-critical applications (e.g., refinery ESD systems).
  4. Advanced Diagnostics: Real-time open-loop, short-circuit, and range alerts enable proactive maintenance, allowing operators to address issues before they cause process disruptions.
  5. Seamless System Integration: Native compatibility with Honeywell ControlEdge PLC and Experion PKS, plus Modbus TCP support for third-party systems, simplifies installation and reduces integration costs.

4. Application Fields & Cases

4.1 Application Fields

  • Oil & Gas: Refinery distillation column temperature/pressure monitoring, pipeline flow rate measurement, wellhead pressure control
  • Petrochemical: Chemical reactor process parameter acquisition, storage tank level monitoring, catalyst dosing control
  • Pharmaceutical: Batch reactor temperature/pressure control, cleanroom environmental monitoring (humidity, pressure)
  • Water/Wastewater: Treatment plant flow rate, pH, and chemical dosing measurement, reservoir level monitoring
  • Power Generation: Boiler steam pressure/temperature data acquisition, turbine lubrication oil pressure monitoring

4.2 Typical Cases

  1. Refinery Distillation Column Control: A major U.S. refinery deployed HONEYWELL 8C-PAINA1 modules in its ControlEdge PLC system to monitor 64 temperature/pressure points across 8 distillation columns. The module’s 16-bit resolution and ±0.05% accuracy enabled precise column control, reducing energy consumption by 8% and improving product yield by 5%.
  2. Pharmaceutical Batch Reactor Monitoring: A European pharmaceutical manufacturer integrated HONEYWELL 8C-PAINA1 into its Experion PKS system to track temperature, pressure, and agitator speed in 12 batch reactors. The module’s isolated channels prevented cross-talk between sensitive sensors, ensuring compliance with FDA process validation requirements and reducing batch rejection rates by 12%.
  3. Water Treatment Plant Flow Control: A municipal water treatment facility in Asia used HONEYWELL 8C-PAINA1 to acquire flow rate and chemical dosing signals (4-20mA) from 40 treatment basins. The module’s open-loop detection identified a faulty flow sensor before it caused over-dosing of chemicals, saving $50,000 in chemical costs and preventing environmental non-compliance.

5. Competitive Comparison

Parameter HONEYWELL 8C-PAINA1 Competitor A (8-channel Analog Input) Competitor B (16-bit AI Module)
Resolution 16-bit 14-bit 16-bit
Accuracy ±0.05% full scale ±0.1% full scale ±0.08% full scale
Isolation Rating 2500V AC (channel-to-channel/ground) 1500V AC (channel-to-ground only) 2000V AC (channel-to-channel)
Redundant Power Support Yes No Yes
SIL Certification SIL 2 No SIL 1
MTBF ≥1,200,000 hours ≥800,000 hours ≥1,000,000 hours

6. Selection Suggestions & Precautions

6.1 Selection Suggestions

  1. Precision Requirements: Choose HONEYWELL 8C-PAINA1 for applications requiring 16-bit resolution and ±0.05% accuracy (e.g., pharmaceutical batch control, refinery process monitoring); 14-bit modules suffice for non-critical monitoring tasks.
  2. Safety & Reliability Needs: Opt for HONEYWELL 8C-PAINA1 for SIL 2 safety-related applications or environments requiring redundant power (e.g., oil & gas facilities); non-isolated modules are suitable for low-risk industrial settings.
  3. System Compatibility: Select HONEYWELL 8C-PAINA1 if using Honeywell ControlEdge PLC/Experion PKS for native integration; third-party AI modules may require additional configuration for Modbus TCP connectivity.

6.2 Precautions

  1. Installation Guidelines:
    • Mount HONEYWELL 8C-PAINA1 on a 35mm DIN rail in a ventilated control cabinet; ensure a minimum of 10mm clearance between modules for heat dissipation.
    • Use shielded twisted-pair cables for analog signal connections (maximum distance 1000m for 4-20mA) and ground the cable shield at one end to minimize noise interference.
  2. Configuration Notes:
    • Calibrate HONEYWELL 8C-PAINA1 via Honeywell’s Control Builder software before commissioning to ensure accuracy over the operating temperature range.
    • Configure open-loop/overrange alerts to trigger alarms in the SCADA/DCS system for proactive fault detection.
  3. Troubleshooting:
    • For inaccurate readings: Check sensor calibration, verify signal wiring (ensure no short circuits), and recalibrate the module if necessary.
    • For fault LEDs: Use the module’s diagnostic data (via Control Builder) to identify channel-specific issues (e.g., open loops, overrange signals).
  4. Maintenance:
    • Inspect module connectors annually for corrosion or loose pins; clean with compressed air to remove dust and debris.
    • Recalibrate HONEYWELL 8C-PAINA1 every 2 years (or per site maintenance protocols) to maintain accuracy and compliance with industry standards.
    • Stock spare HONEYWELL 8C-PAINA1 modules for critical applications—lead times for Honeywell industrial automation components may exceed 6 weeks.

8C-PAINA1

CP-20A-5-J601A-SP PLC
PCD235A101 PLC
1SAJ924007R0001 PLC
25-80-60090 PLC
SC510 PLC
5SHY3545L0014 PLC

Reviews

There are no reviews yet.

Be the first to review “HONEYWELL 8C-PAINA1”

Your email address will not be published. Required fields are marked *

Post comment