Description
1. Product Overview
HIMA F6220 is a high-performance digital input module designed for HIMA HIMatrix safety instrumented systems (SIS), specializing in SIL 3-certified discrete signal detection for critical industrial applications. As a versatile member of HIMA’s HIMatrix F600 series, HIMA F6220 provides 16 channels of isolated digital input, optimized for balanced density and reliability in oil & gas, petrochemical, power generation, and pharmaceutical industries. In offshore platform emergency shutdown (ESD) systems, HIMA F6220 monitors pressure switches and emergency stop buttons; in chemical reactor control, HIMA F6220 processes safety interlock signals from temperature and level sensors; in food & beverage manufacturing, HIMA F6220 ensures compliance with hygiene and safety regulations for production lines. Additionally, HIMA F6220 integrates advanced diagnostics and rugged design, making it a reliable choice for both hazardous and non-hazardous industrial environments.
2. Product Parameters
2.1 Core Input Specifications
- Input Channels: 16 isolated digital input channels (2 channels per group, galvanic isolation between groups)
- Input Type: Dry contact (NO/NC), wet contact (24V DC), TTL-compatible signals (0-5V DC)
- Input Voltage Range: 18-30V DC (wet contact), 0-5V DC (TTL)
- Response Time: ≤2ms (signal detection to backplane transmission)
- Isolation Rating: 500V AC between channels (group-to-group), 2500V AC between module and backplane
2.2 Electrical & Communication Parameters
- Power Supply: 24V DC (supplied by HIMA HIMatrix SIS rack), power consumption ≤8W
- Backplane Interface: HIMA HIMatrix internal bus (Ethernet-based), 100Mbps full-duplex
- Diagnostic Features: Open-circuit detection, short-circuit detection, channel fault status feedback, module self-test (BIT), LED per-channel status indicators
- Input Logic: Configurable (normally open/normally closed, positive/negative logic)
- Redundancy Support: Compatible with HIMA HIMatrix 1oo2 and 2oo3 fault-tolerant SIS architectures
2.3 Environmental & Mechanical Parameters
- Operating Temperature: -20°C to +60°C (industrial-grade range)
- Storage Temperature: -40°C to +85°C
- Relative Humidity: 5% to 95% (non-condensing), IP20 protection
- Vibration Resistance: 5-2000Hz, 2g (IEC 60068-2-6, X/Y/Z axes)
- Shock Resistance: 15g (11ms half-sine wave, IEC 60068-2-27)
- Mounting: HIMA HIMatrix rack-mounted, hot-swappable (plug-in module)
- Dimensions: 48mm (W) × 220mm (H) × 180mm (D), standard rack compatibility
2.4 Certifications & Compatibility
- Safety Certifications: SIL 3 (IEC 61508/61511), TÜV Rheinland, ATEX Zone 2 (Ex nA IIC T4)
- Industry Certifications: CE, UL/cUL Class 1 Div 2, FCC Class A, RoHS
- Compatibility: HIMA HIMatrix F65/F75 controllers, HIMA SafetyBUS p networks, third-party 24V DC sensors/switches
- MTBF: ≥1,000,000 hours (per Telcordia SR-332 standards)
3. Advantages & Features
- SIL 3 Fault Tolerance: HIMA F6220 is certified for SIL 3 applications and integrates with HIMA’s redundant SIS architectures, eliminating single points of failure and ensuring compliance with the strictest safety standards for discrete signal detection.
- Isolated Channel Design: Galvanic isolation between channel groups prevents cross-channel interference and protects against electrical faults, ensuring reliable operation in noisy industrial environments (e.g., near VFDs or high-voltage equipment).
- Per-Channel Diagnostics: Unlike group-level diagnostic modules, HIMA F6220 provides individual channel fault detection (open/short-circuit), enabling precise identification of faulty sensors or wiring and reducing maintenance time.
- Hot-Swappable & Easy to Maintain: HIMA F6220 supports hot-swapping in live SIS systems, allowing module replacement without disrupting safety operations. Front-panel LED indicators for each channel simplify troubleshooting, minimizing downtime.
- Broad Environmental Compatibility: The -20°C to +60°C operating range and robust vibration/shock resistance make HIMA F6220 suitable for deployment in extreme environments, from offshore platforms to desert refineries.
4. Application Fields & Cases
4.1 Application Fields
- Oil & Gas: Offshore platform ESD systems, pipeline leak detection, refinery process unit monitoring
- Petrochemical: Chemical reactor safety interlocks, burner management systems, storage tank overfill protection
- Power Generation: Turbine emergency stop detection, boiler safety interlocks, renewable energy grid safety switches
- Pharmaceutical: Cleanroom safety interlocks, batch manufacturing process controls, hazardous material handling systems
4.2 Typical Cases
- Offshore Platform ESD System: A Norwegian offshore oil platform deployed HIMA F6220 modules in its HIMatrix SIS to monitor 64 safety switches (pressure, level, emergency stop) across 4 wellhead control panels. The module’s per-channel diagnostics identified a faulty emergency stop button wiring short, allowing maintenance crews to repair the issue before it caused a false ESD trigger and $300,000 in downtime.
- Chemical Reactor Control: A German chemical plant integrated HIMA F6220 into its HIMatrix SIS to process safety interlock signals from temperature and pressure sensors in batch reactors. The module’s SIL 3 certification and fast response time (≤2ms) ensured immediate shutdown of reactors during overpressure events, preventing equipment damage and ensuring compliance with EU safety regulations.
- Pharmaceutical Cleanroom Operations: A U.S. pharmaceutical manufacturer used HIMA F6220 to monitor door interlocks and air pressure sensors in sterile cleanrooms. The module’s ATEX Zone 2 certification and isolated channel design ensured safe operation in areas with flammable solvent vapors, while hot-swappable design allowed maintenance without disrupting production schedules.
5. Competitive Comparison
| Parameter | HIMA F6220 | Competitor A (SIL 2 DI Module) | Competitor B (Non-Redundant DI Module) |
|---|---|---|---|
| Safety Certification | SIL 3 (IEC 61508) | SIL 2 | No SIL Certification |
| Input Channels | 16 (isolated) | 16 (non-isolated) | 16 (non-isolated) |
| Diagnostic Level | Per-channel | Group-level | None |
| Operating Temperature | -20°C to +60°C | -10°C to +50°C | 0°C to +50°C |
| Hot-Swappable | Yes | No | No |
| MTBF | ≥1,000,000 hours | ≥600,000 hours | ≥500,000 hours |
6. Selection Suggestions & Precautions
6.1 Selection Suggestions
- Safety Level & Diagnostic Needs: Choose HIMA F6220 for SIL 3 applications requiring per-channel diagnostics (e.g., offshore ESD, chemical reactor control); for SIL 2 applications, consider HIMA’s F6210 module or competitor SIL 2 products.
- Environmental Requirements: Select HIMA F6220 for extreme temperature or high-vibration environments; standard modules may lack the durability for these conditions.
- System Compatibility: Opt for HIMA F6220 if integrating with HIMA HIMatrix SIS to ensure seamless communication and redundancy support; third-party modules may require custom interface hardware.
6.2 Precautions
- Installation Guidelines:
- Install HIMA F6220 in HIMA-certified HIMatrix racks only; ensure proper grounding (≤4Ω) to minimize electromagnetic interference (EMI) with input signals.
- Use shielded twisted-pair cables (24 AWG) for wet contact inputs, with shielding grounded at the sensor end to reduce noise.
- Configuration Notes:
- Configure input logic (NO/NC, positive/negative) via HIMA Safety Workbench software to match field device specifications (e.g., NC for emergency stop buttons).
- Enable per-channel fault logging to track intermittent issues (e.g., loose sensor wiring) that may not trigger immediate alarms.
- Troubleshooting:
- For individual channel faults: Check the corresponding sensor wiring, input voltage, and LED status; use Safety Workbench to verify channel configuration.
- For communication errors: Verify backplane connections and update module firmware (via Safety Workbench) to ensure compatibility with the host controller.
- Hot-swapping: Follow HIMA procedures (deactivate the module via software) to avoid disrupting redundant systems during replacement.
- Maintenance:
- Inspect connector pins and backplane contacts every 12 months for corrosion; clean with HIMA-approved contact cleaner to maintain signal integrity.
- Test input response time and isolation resistance every 2 years using a calibrated signal generator and megohmmeter.
- Stock spare HIMA F6220 modules for critical applications—lead times for SIL 3-certified components may exceed 6 weeks.


F6220
990NAA26320
MA0185100 I/O
MA0186100 I/O
MA0329001 I/OF(10/)
140XTS00200 PLC
490NRP95400
140NRP95400


Reviews
There are no reviews yet.