HIMA F6220

¥999.00

HIMA F6220 is a high-performance digital input module designed for HIMA HIMatrix safety instrumented systems (SIS), specializing in SIL 3-certified discrete signal detection for critical industrial applications. As a versatile member of HIMA’s HIMatrix F600 series, HIMA F6220 provides 16 channels of isolated digital input, optimized for balanced density and reliability in oil & gas, petrochemical, power generation, and pharmaceutical industries. In offshore platform emergency shutdown (ESD) systems, HIMA F6220 monitors pressure switches and emergency stop buttons; in chemical reactor control, HIMA F6220 processes safety interlock signals from temperature and level sensors; in food & beverage manufacturing, HIMA F6220 ensures compliance with hygiene and safety regulations for production lines. Additionally, HIMA F6220 integrates advanced diagnostics and rugged design, making it a reliable choice for both hazardous and non-hazardous industrial environments.

Category:

Description

1. Product Overview

HIMA F6220 is a high-performance digital input module designed for HIMA HIMatrix safety instrumented systems (SIS), specializing in SIL 3-certified discrete signal detection for critical industrial applications. As a versatile member of HIMA’s HIMatrix F600 series, HIMA F6220 provides 16 channels of isolated digital input, optimized for balanced density and reliability in oil & gas, petrochemical, power generation, and pharmaceutical industries. In offshore platform emergency shutdown (ESD) systems, HIMA F6220 monitors pressure switches and emergency stop buttons; in chemical reactor control, HIMA F6220 processes safety interlock signals from temperature and level sensors; in food & beverage manufacturing, HIMA F6220 ensures compliance with hygiene and safety regulations for production lines. Additionally, HIMA F6220 integrates advanced diagnostics and rugged design, making it a reliable choice for both hazardous and non-hazardous industrial environments.

2. Product Parameters

2.1 Core Input Specifications

  • Input Channels: 16 isolated digital input channels (2 channels per group, galvanic isolation between groups)
  • Input Type: Dry contact (NO/NC), wet contact (24V DC), TTL-compatible signals (0-5V DC)
  • Input Voltage Range: 18-30V DC (wet contact), 0-5V DC (TTL)
  • Response Time: ≤2ms (signal detection to backplane transmission)
  • Isolation Rating: 500V AC between channels (group-to-group), 2500V AC between module and backplane

2.2 Electrical & Communication Parameters

  • Power Supply: 24V DC (supplied by HIMA HIMatrix SIS rack), power consumption ≤8W
  • Backplane Interface: HIMA HIMatrix internal bus (Ethernet-based), 100Mbps full-duplex
  • Diagnostic Features: Open-circuit detection, short-circuit detection, channel fault status feedback, module self-test (BIT), LED per-channel status indicators
  • Input Logic: Configurable (normally open/normally closed, positive/negative logic)
  • Redundancy Support: Compatible with HIMA HIMatrix 1oo2 and 2oo3 fault-tolerant SIS architectures

2.3 Environmental & Mechanical Parameters

  • Operating Temperature: -20°C to +60°C (industrial-grade range)
  • Storage Temperature: -40°C to +85°C
  • Relative Humidity: 5% to 95% (non-condensing), IP20 protection
  • Vibration Resistance: 5-2000Hz, 2g (IEC 60068-2-6, X/Y/Z axes)
  • Shock Resistance: 15g (11ms half-sine wave, IEC 60068-2-27)
  • Mounting: HIMA HIMatrix rack-mounted, hot-swappable (plug-in module)
  • Dimensions: 48mm (W) × 220mm (H) × 180mm (D), standard rack compatibility

2.4 Certifications & Compatibility

  • Safety Certifications: SIL 3 (IEC 61508/61511), TÜV Rheinland, ATEX Zone 2 (Ex nA IIC T4)
  • Industry Certifications: CE, UL/cUL Class 1 Div 2, FCC Class A, RoHS
  • Compatibility: HIMA HIMatrix F65/F75 controllers, HIMA SafetyBUS p networks, third-party 24V DC sensors/switches
  • MTBF: ≥1,000,000 hours (per Telcordia SR-332 standards)

3. Advantages & Features

  1. SIL 3 Fault ToleranceHIMA F6220 is certified for SIL 3 applications and integrates with HIMA’s redundant SIS architectures, eliminating single points of failure and ensuring compliance with the strictest safety standards for discrete signal detection.
  2. Isolated Channel Design: Galvanic isolation between channel groups prevents cross-channel interference and protects against electrical faults, ensuring reliable operation in noisy industrial environments (e.g., near VFDs or high-voltage equipment).
  3. Per-Channel Diagnostics: Unlike group-level diagnostic modules, HIMA F6220 provides individual channel fault detection (open/short-circuit), enabling precise identification of faulty sensors or wiring and reducing maintenance time.
  4. Hot-Swappable & Easy to MaintainHIMA F6220 supports hot-swapping in live SIS systems, allowing module replacement without disrupting safety operations. Front-panel LED indicators for each channel simplify troubleshooting, minimizing downtime.
  5. Broad Environmental Compatibility: The -20°C to +60°C operating range and robust vibration/shock resistance make HIMA F6220 suitable for deployment in extreme environments, from offshore platforms to desert refineries.

4. Application Fields & Cases

4.1 Application Fields

  • Oil & Gas: Offshore platform ESD systems, pipeline leak detection, refinery process unit monitoring
  • Petrochemical: Chemical reactor safety interlocks, burner management systems, storage tank overfill protection
  • Power Generation: Turbine emergency stop detection, boiler safety interlocks, renewable energy grid safety switches
  • Pharmaceutical: Cleanroom safety interlocks, batch manufacturing process controls, hazardous material handling systems

4.2 Typical Cases

  1. Offshore Platform ESD System: A Norwegian offshore oil platform deployed HIMA F6220 modules in its HIMatrix SIS to monitor 64 safety switches (pressure, level, emergency stop) across 4 wellhead control panels. The module’s per-channel diagnostics identified a faulty emergency stop button wiring short, allowing maintenance crews to repair the issue before it caused a false ESD trigger and $300,000 in downtime.
  2. Chemical Reactor Control: A German chemical plant integrated HIMA F6220 into its HIMatrix SIS to process safety interlock signals from temperature and pressure sensors in batch reactors. The module’s SIL 3 certification and fast response time (≤2ms) ensured immediate shutdown of reactors during overpressure events, preventing equipment damage and ensuring compliance with EU safety regulations.
  3. Pharmaceutical Cleanroom Operations: A U.S. pharmaceutical manufacturer used HIMA F6220 to monitor door interlocks and air pressure sensors in sterile cleanrooms. The module’s ATEX Zone 2 certification and isolated channel design ensured safe operation in areas with flammable solvent vapors, while hot-swappable design allowed maintenance without disrupting production schedules.

5. Competitive Comparison

Parameter HIMA F6220 Competitor A (SIL 2 DI Module) Competitor B (Non-Redundant DI Module)
Safety Certification SIL 3 (IEC 61508) SIL 2 No SIL Certification
Input Channels 16 (isolated) 16 (non-isolated) 16 (non-isolated)
Diagnostic Level Per-channel Group-level None
Operating Temperature -20°C to +60°C -10°C to +50°C 0°C to +50°C
Hot-Swappable Yes No No
MTBF ≥1,000,000 hours ≥600,000 hours ≥500,000 hours

6. Selection Suggestions & Precautions

6.1 Selection Suggestions

  1. Safety Level & Diagnostic Needs: Choose HIMA F6220 for SIL 3 applications requiring per-channel diagnostics (e.g., offshore ESD, chemical reactor control); for SIL 2 applications, consider HIMA’s F6210 module or competitor SIL 2 products.
  2. Environmental Requirements: Select HIMA F6220 for extreme temperature or high-vibration environments; standard modules may lack the durability for these conditions.
  3. System Compatibility: Opt for HIMA F6220 if integrating with HIMA HIMatrix SIS to ensure seamless communication and redundancy support; third-party modules may require custom interface hardware.

6.2 Precautions

  1. Installation Guidelines:
    • Install HIMA F6220 in HIMA-certified HIMatrix racks only; ensure proper grounding (≤4Ω) to minimize electromagnetic interference (EMI) with input signals.
    • Use shielded twisted-pair cables (24 AWG) for wet contact inputs, with shielding grounded at the sensor end to reduce noise.
  2. Configuration Notes:
    • Configure input logic (NO/NC, positive/negative) via HIMA Safety Workbench software to match field device specifications (e.g., NC for emergency stop buttons).
    • Enable per-channel fault logging to track intermittent issues (e.g., loose sensor wiring) that may not trigger immediate alarms.
  3. Troubleshooting:
    • For individual channel faults: Check the corresponding sensor wiring, input voltage, and LED status; use Safety Workbench to verify channel configuration.
    • For communication errors: Verify backplane connections and update module firmware (via Safety Workbench) to ensure compatibility with the host controller.
    • Hot-swapping: Follow HIMA procedures (deactivate the module via software) to avoid disrupting redundant systems during replacement.
  4. Maintenance:
    • Inspect connector pins and backplane contacts every 12 months for corrosion; clean with HIMA-approved contact cleaner to maintain signal integrity.
    • Test input response time and isolation resistance every 2 years using a calibrated signal generator and megohmmeter.
    • Stock spare HIMA F6220 modules for critical applications—lead times for SIL 3-certified components may exceed 6 weeks.