Description
Product Description
Product Parameters
| Parameter | Specification |
|---|---|
| Model | GE SR489-P1-HI-A20-E |
| Type | Generator Management Relay |
| Brand | GE Multilin |
| Phase Current Input | P1 (1A phase CT secondary) |
| Analog Output | A20 (4-20 mA) |
| Control Power | 90-300 VDC, 70-265 VAC |
| Frequency Range | 48-62 Hz |
| Relay Operation Time | 10 ms |
| Energy Metering Update Rate | 50 ms |
| Display | Enhanced LCD (E) |
| Communication | RS232, IRIG-B TTL compatible |
| Operating Temperature | -25°C to +50°C |
| Mounting | Panel-mounted (draw-out) |
| Certifications | IEC 60529, UL 508 |
| Isolation Voltage | 36 Vpk |
Advantages and Features
- Comprehensive Protection: The GE SR489-P1-HI-A20-E offers overcurrent, overvoltage, undervoltage, under/overfrequency, phase reversal, and dual-slope phase differential protection for complete generator safeguarding.
- Fast Response & Accuracy: 10ms relay operation time and 50ms energy metering update rate ensure rapid fault detection and precise monitoring.
- Enhanced User Interface: The enhanced LCD display (E) provides real-time parameter visibility, while RS232 communication enables remote configuration via EnerVista software.
- Hot-Swap Maintenance: Draw-out design allows replacement without system shutdown, minimizing downtime in critical power applications.
- Wide Power Compatibility: 90-300 VDC and 70-265 VAC control power range ensures adaptability to diverse industrial power systems.
Application Cases in Application Fields
- Industrial Cogeneration Plant: The GE SR489-P1-HI-A20-E protects 4×1MW gas generators, reducing false trips by 25% vs. legacy relays and enabling 15-minute hot-swap during outages.
- Data Center Backup Generators: It monitors 3×500kW diesel generators, providing underfrequency/overfrequency protection and 4-20mA output for remote load shedding control.
- Offshore Oil Platform: The GE SR489-P1-HI-A20-E safeguards 2×2MW gas turbines, with -25°C operation ensuring reliability in subsea environments.
- Water Treatment Plant: It integrates with SCADA to protect 6×300kW pump generators, using phase reversal protection to prevent motor damage from reverse rotation.
Comparisons with Competing Products
| Feature | GE SR489-P1-HI-A20-E | Competitor A (Schneider Electric Sepam 20) | Competitor B (ABB Relion 615) |
|---|---|---|---|
| Phase CT Input | 1A (P1) | 5A only | 1A/5A selectable |
| Analog Output | 4-20 mA (A20) | 0-20 mA | 4-20 mA |
| Relay Operation Time | 10 ms | 20-30 ms | 15-20 ms |
| Display | Enhanced LCD | Basic LCD | Color LCD |
| Hot-Swap | Yes (draw-out) | No | Yes |
| Communication | RS232, IRIG-B | Modbus RTU only | Ethernet, Modbus TCP |
| Price Range | $1,200-$1,800 | $1,500-$2,200 | $1,800-$2,500 |
Selection Suggestions and Precautions
- Selection Suggestions
- Select the GE SR489-P1-HI-A20-E for small-to-medium generators requiring comprehensive protection, fast response, and hot-swap maintenance.
- Pair with surge protectors and voltage regulators in unstable grid environments to enhance transient resilience.
- Use with EnerVista software for remote configuration and real-time monitoring, optimizing operational efficiency.
- Precautions
- Ensure CT secondary compatibility (1A) to avoid measurement errors and relay misoperation.
- Verify control power (90-300 VDC/70-265 VAC) matches the system to prevent damage to the GE SR489-P1-HI-A20-E.
- Follow lockout-tagout during hot-swap to prevent electrical hazards in live generator environments.
- Calibrate annually to maintain 10ms operation time and 50ms metering accuracy for reliable fault detection.

YT204001-KA PLC
80190-300-01-R PLC
1771-NRC PLCPC
90P18X6D1C4D
2711-T10G8B
2711-T10G3B


Reviews