Description
Product Parameters
| Parameter | Specification |
|---|---|
| Model | IS230TNCIH4 |
| Manufacturer | GE Energy / Baker Hughes |
| Platform | Mark VIe |
| Type | Analog I/O termination board (current/voltage) |
| Compatible Modules | IS220PAICH1A, IS220PAICH1B, IS220PIOAH1A |
| Analog Input Channels | Up to 8 (depending on module configuration) |
| Analog Output Channels | Up to 4 (depending on module configuration) |
| Signal Type | Current: 4–20 mA, 0–20 mA; Voltage: 0–10 V, ±10 V (jumper selectable) |
| Terminal Type | Screw‑clamp (pluggable, 2‑piece) |
| Number of Positions | 24 positions (field wiring side) |
| Wire Gauge | 0.2–2.5 mm² (AWG 24–14) |
| Termination Resistors | Configurable (typically 250 Ω for current inputs) |
| Signal Conditioning | Configurable termination resistors, RC filters, basic ESD protection |
| Isolation | 1500 V (field‑to‑backplane via module) |
| LED Indicators | None (status via I/O module) |
| Operating Temperature | -30°C to +65°C |
| Storage Temperature | -40°C to +85°C |
| Humidity | 5% to 95% (non‑condensing) |
| Dimensions | Standard Mark VIe terminal board form factor |
| Weight | Approx. 0.40 kg |
| MTBF | > 180,000 hours |
Advantages and Key Features
-
Dedicated Current/Voltage Termination – The IS230TNCIH4 is specifically optimized for current and voltage analog signals, providing reliable termination for the IS220PAICH1A, IS220PAICH1B, and IS220PIOAH1A modules.
-
Jumper‑Configurable Signal Type – Each channel on the IS230TNCIH4 can be configured for current (4–20 mA, 0–20 mA) or voltage (0–10 V, ±10 V) via simple jumper settings, providing flexibility for mixed signal applications.
-
Integrated Termination Resistors – Provides mounting locations for termination resistors (typically 250 Ω) for current inputs, eliminating the need for external resistor installation.
-
High-Density Analog Termination – Supports up to 8 analog inputs and 4 analog outputs per board, offering a compact and organized interface for field wiring.
-
Pluggable Terminal Design – The IS230TNCIH4 features a 2‑piece pluggable terminal block design, allowing field wiring to be disconnected without removing individual wires, simplifying maintenance and module replacement.
-
Basic ESD Protection – Provides basic ESD protection (IEC 61000‑4‑2 Level 3) to protect the IS230TNCIH4 and connected I/O modules from electrostatic discharge.
-
Wide Wire Range – Accepts wire gauges from AWG 24 to AWG 14, accommodating both small‑gauge instrument wiring and larger power connections.
-
Flame‑Retardant Housing – UL 94 V‑0 rated material provides safety in the event of electrical faults.
Application Fields and Use Cases
1. Pressure Monitoring
The IS230TNCIH4 connects 4–20 mA pressure transmitters to the IS220PAICH1B, providing critical pressure data for turbine control and protection.
2. Flow Monitoring
Provides connections for 4–20 mA flow meters for monitoring fuel gas, steam, and cooling water flow.
3. Temperature Transmitter Monitoring
Connects 4–20 mA temperature transmitters, enabling temperature monitoring without direct thermocouple or RTD termination.
4. Valve Positioner Control
Provides connections for 4–20 mA analog outputs to valve positioners, enabling precise control of fuel valves, steam admission valves, and other actuators.
5. Level Monitoring
Connects 4–20 mA level transmitters in auxiliary systems (lube oil tanks, water treatment) for automated control and alarm annunciation.
6. Retrofit Projects
The IS230TNCIH4 is a cost‑effective analog termination solution for Mark VIe upgrades from legacy Mark VI analog termination boards (IS200TNCIH4), offering pluggable connections and improved reliability.
Comparison with Competing Products
| Feature | IS230TNCIH4 (GE) | IS230TNAIH4C (GE) | IS230TBTCH1B (GE) | ABB TU830 (AC 800M) | Siemens 6ES7 392-1AJ00 (S7-400) |
|---|---|---|---|---|---|
| Platform | Mark VIe | Mark VIe | Mark VIe | AC 800M | S7-400 |
| Type | Analog (current/voltage) | Analog (current/voltage) | Universal | Terminal unit | Terminal block |
| Analog Capacity | 8 inputs + 4 outputs | 8 inputs + 4 outputs | Up to 32 mixed | 8–16 mixed | 8 mixed |
| Signal Configuration | Jumper selectable | Jumper selectable | Configurable | Configurable | Limited |
| Termination Resistors | Configurable (250 Ω) | Configurable | Configurable | Configurable | External |
| Terminal Type | Screw, pluggable | Screw, pluggable | Screw, pluggable | Screw, pluggable | Screw, fixed |
| Pluggable | Yes | Yes | Yes | Yes | No |
| Wire Gauge | AWG 24–14 | AWG 24–14 | AWG 24–14 | AWG 24–14 | AWG 24–12 |
| Isolation | Via module (1500 V) | Via module (1500 V) | Via module (1500 V) | Via module (1500 V) | Via module (500 V) |
| Temp Range | -30°C to +65°C | -30°C to +65°C | -40°C to +85°C | -25°C to +60°C | 0°C to +60°C |
| MTBF | > 180,000 hrs | > 180,000 hrs | > 200,000 hrs | > 120,000 hrs | > 80,000 hrs |
Key Differentiators: The IS230TNCIH4 is a cost‑effective analog termination board with jumper‑configurable current/voltage signal support. It offers similar functionality to the IS230TNAIH4C with a slightly simplified design. Compared to the universal IS230TBTCH1B, the IS230TNCIH4 is specifically optimized for analog signals, providing simpler configuration for analog applications. Its pluggable design significantly improves maintainability over legacy Mark VI boards.
Selection Suggestions and Precautions
Selection Criteria
-
Choose the IS230TNCIH4 for analog I/O applications requiring dedicated current/voltage signal termination with the IS220PAICH1A, IS220PAICH1B, or IS220PIOAH1A modules.
-
For applications with mixed signal types (analog, discrete, temperature), consider the IS230TBTCH1B.
-
Verify the number of analog inputs and outputs matches the I/O module capacity (8 inputs, 4 outputs for IS220PAICH1B).
-
Ensure proper channel configuration: jumper settings must match the module configuration (voltage or current).
Critical Precautions
-
Jumper Configuration – Configure each channel on the IS230TNCIH4 for the correct signal type (voltage or current) using jumpers before connecting field wiring. Incorrect configuration can damage the module or produce erroneous readings.
-
Termination Resistors – For 4–20 mA current inputs, install the required termination resistors (typically 250 Ω) on the IS230TNCIH4. For voltage inputs, remove or bypass termination resistors.
-
Loop Power – The IS230TNCIH4 does not provide loop power for 4–20 mA transmitters. Ensure external power supplies are provided for loop‑powered devices.
-
Shielding – Use shielded twisted‑pair cables for all analog connections to the IS230TNCIH4. Terminate shields at the field device end, not at the board, to prevent ground loops.
-
Polarity – For DC signals, observe proper polarity on the IS230TNCIH4 to prevent incorrect readings and potential damage.
-
Wiring – Use appropriate wire gauge (AWG 24–14). Recommended torque: 0.5–0.6 N·m. Over‑tightening may damage terminals; under‑tightening may cause intermittent connections.
-
Grounding – Ensure all field devices and the Mark VIe chassis share a common reference ground to prevent ground loops.
-
ESD Handling – Use grounded wrist straps when handling the IS230TNCIH4 to prevent static damage.
-
Obsolescence – The IS230TNCIH4 is in active production with long‑term support. For future projects requiring additional analog channels or enhanced features, evaluate the IS230TNCIH4A or IS230TNCIH4B when available. Keep spare boards for critical analog applications.

ABB CM572-DP 1SAP170200R0001
A-B 1746-IN16
HYDAC DF ON 60 QE 3 D 1.0/L24-B6
A-B 1746-IN16