Description
Key Specifications
| Parameter | Specification |
|---|---|
| Vibration Inputs | 12 IEPE/accelerometer inputs, 6 proximity probe inputs — increased |
| Vibration Measurement | Displacement (µm), velocity (mm/s), acceleration (g) |
| Frequency Range | DC to 30 kHz — improved |
| Sampling Rate | Up to 75 kHz per channel (simultaneous) — improved |
| Dynamic Analysis | On-board FFT, spectrum analysis, order analysis, transfer function, cascade plots — expanded |
| Control Outputs | 6 analog outputs (4–20 mA, ±10 V) for active vibration control — increased |
| Digital I/O | 12 digital inputs, 12 digital outputs (24 VDC) — increased |
| Control Modes | Active vibration control, dynamic response shaping, adaptive filtering, modal control — new |
| Communication | 2 Ethernet ports (10/100/1000Base-T) |
| Protocol Support | I/O Net, Modbus TCP, EtherNet/IP, OPC UA, DNP3 — expanded |
| Diagnostics | 1000-event fault log with timestamps, vibration snapshots, and spectrum snapshots — expanded |
| Isolation | 1500 VDC (I/O-to-backplane) |
| Form Factor | 6U VME64x (160 × 233 mm), single-slot width |
| Operating Temp | –25 °C to +70 °C — extended |
| Power Draw | 20 W (+5 V / +3.3 VDC) + external 24 VDC field power |
| Connectors | 48-pin terminal block with gold-plated contacts + RJ45 |
Advantages & Distinctive Features
-
Higher Channel Density: 12 IEPE + 6 proximity inputs—more channels per slot.
-
Faster Sampling: 75 kHz per channel for higher-frequency fault detection.
-
Expanded Dynamic Analysis: Added cascade plots and transfer function analysis.
-
More Control Outputs: 6 analog outputs for active control applications.
-
New Control Mode: Modal control for multi-mode vibration suppression.
-
Extended Temperature Range: –25 °C to +70 °C.
-
Expanded Diagnostics: 1000-event fault log with vibration/spectrum snapshots.
-
Hot-Swappable: No rack power-down for replacement.
-
Direct Retrofit: Replaces older UCVD series boards.
Application Fields
-
Gas Turbines: Vibration monitoring, active control, modal analysis
-
Steam Turbines: Vibration monitoring, active control
-
Compressors: Active vibration suppression, modal control
-
Generators: Vibration monitoring, modal analysis
-
High-Speed Rotating Machinery: Advanced vibration control and monitoring
-
Research & Development: Dynamic analysis, modal testing
Comparison with UCVDH1A and Competitors
| Feature | GE IS215UCVDH2A | GE IS215UCVDH1A | Competitor A | Competitor B |
|---|---|---|---|---|
| IEPE Inputs | 12 | 8 | 8 | 12 |
| Proximity Inputs | 6 | 4 | 4 | 6 |
| Sampling Rate | 75 kHz | 50 kHz | 20 kHz | 75 kHz |
| Cascade Plots | Yes | No | No | Yes |
| Transfer Function | Yes | Yes | No | Yes |
| Modal Control | Yes | No | No | Yes |
| Control Outputs | 6 | 4 | None | 4 |
| Temp Range | –25 to +70 °C | 0 to +60 °C | 0 to +55 °C | –25 to +70 °C |
| Fault Logging | 1000 events + snapshots | 750 events + snapshots | No | 750 events |
Selection Guidelines
-
When to choose: Applications requiring higher channel density, faster sampling, and advanced control modes for vibration suppression.
-
Vibration Input Configuration: Configure IEPE or proximity probes per channel.
-
Control Mode: Select active vibration control, dynamic response shaping, adaptive filtering, or modal control.
-
Dynamic Analysis: Configure FFT, spectrum, order, transfer function, and cascade plots.
-
Modal Control: Configure for multi-mode vibration suppression.
-
Compatibility: Fits all Mark VIe VME64x racks. Requires ControlST v7.5 or higher.
Operational Precautions
-
Wiring: Follow GE wiring diagrams—correct polarity for vibration sensors.
-
Vibration Sensor Verification: Verify sensor type and sensitivity during commissioning.
-
Control Tuning: Tune active control algorithms during commissioning.
-
Modal Control Tuning: Tune modal control parameters for multi-mode suppression.
-
Dynamic Analysis Baseline: Review baseline FFT, transfer functions, and cascade plots.
-
LED Diagnostics: Green = normal; Amber = fault; Red = module fault.
-
Fault Log: Access 1000-event log via Toolbox ST—review vibration/spectrum snapshots.
-
Hot-Swap: Remove/insert slowly under power.
-
Spare Stock: Maintain 1 spare per 3–4 racks.
-
Firmware Updates: Ensure the GE IS215UCVDH2A is in “standby” mode.
-
ESD: Handle by edges with grounded wrist strap.

Schneider TSXDST1612
A-B 1747-SDN
A-B 1746-NO4V
A-B 1747-SDN