Description
Key Specifications
| Parameter | Specification |
|---|---|
| Bridge Sensor Inputs | 8 dedicated bridge sensor inputs (strain gauges, pressure transducers, load cells) |
| Bridge Excitation | Programmable (0.5 V, 1 V, 2.5 V, 5 V, 10 V) |
| Bridge Sensor Resolution | 24-bit ADC |
| Bridge Sensor Accuracy | ±0.04% of full scale (improved over H1A) |
| Pressure Inputs | 8 differential analog inputs (4–20 mA, 0–10 V) |
| Pressure Input Accuracy | ±0.04% of full scale (improved over H1A) |
| Pulse/Frequency Inputs | 4 high-speed pulse/frequency input channels |
| Pulse Input Range | 0.5 Hz to 50 kHz |
| Pulse Accuracy | ±0.008% of reading (improved over H1A) |
| Analog Control Outputs | 4 isolated analog output channels (4–20 mA, 0–10 V, ±10 V) |
| Output Resolution | 16-bit DAC |
| Output Accuracy | ±0.04% of full scale (improved over H1A) |
| Control Functions | PID control, feedforward control, valve positioning, pressure control |
| Isolation | 1500 VDC (I/O-to-backplane) |
| Diagnostics | 750-event fault log with timestamps (expanded over H1A) |
| Operating Temp | –25 °C to +70 °C (extended range) |
| Humidity | 5–95% non-condensing (with conformal coating) |
| Coating | Conformal coating (standard) — UV-traceable |
| Manufacturing | 96-hour burn-in, 100% X-Ray/AOI, premium component selection |
| Form Factor | 6U VME64x (160 × 233 mm), single-slot width |
| Power | 16 W (+5 V / +3.3 VDC) |
| Connectors | 48-pin terminal block with gold-plated contacts and captive washer screws |
Advantages & Distinctive Features
-
Multi-Signal Acquisition and Control: Combines bridge, pressure, pulse inputs, and analog control outputs.
-
Improved Accuracy: ±0.04% bridge/pressure, ±0.008% pulse accuracy.
-
Versatile Bridge Inputs: 8 bridge inputs with programmable excitation.
-
High-Speed Pulse Inputs: 4 pulse/frequency channels for speed sensors and flowmeters.
-
Integrated Control Outputs: 4 analog outputs for actuator and valve control.
-
On-Board Control Logic: PID and feedforward control reduces processor load.
-
Conformal Coating Standard: Protects against humidity, salt spray, and chemicals.
-
Extended Temperature Range: –25 °C to +70 °C.
-
Expanded Diagnostic Log: 750-event fault log.
-
Gold-Plated Captive Washer Terminals: Corrosion-resistant and vibration-proof.
-
Hot-Swappable: No rack power-down for replacement.
-
Direct Retrofit: Replaces older BPPC series boards.
Application Fields
-
Gas Turbines: Fuel control, speed monitoring, pressure monitoring
-
Steam Turbines: Valve positioning, speed monitoring, pressure monitoring
-
Compressors: Surge control, speed monitoring, pressure
-
Boiler Control: Pressure monitoring, valve positioning, feedwater control
-
Offshore platforms: Salt-spray environments requiring conformal coating
Comparison with BPPCH1A and Competitors
| Feature | GE IS210BPPCH1AC | GE IS210BPPCH1A | Competitor A | Competitor B |
|---|---|---|---|---|
| Bridge Inputs | 8 | 8 | None | None |
| Pressure Inputs | 8 | 8 | 8 | 8 |
| Pulse Inputs | 4 (50 kHz) | 4 (50 kHz) | None | 2 (50 kHz) |
| Analog Outputs | 4 | 4 | None | None |
| Accuracy (bridge) | ±0.04% | ±0.05% | N/A | ±0.05% |
| Coating | Standard | Optional | Optional | Optional |
| Temp Range | –25 to +70 °C | 0 to +60 °C | 0 to +55 °C | –10 to +55 °C |
| Fault Logging | 750 events | 500 events | No | No |
Selection Guidelines
-
When to choose: Critical measurement and control applications requiring combined bridge, pressure, pulse, and analog outputs with environmental protection.
-
When to choose “H1A” instead: For clean, controlled environments where conformal coating is not required.
-
Bridge Configuration: Configure excitation voltage per manufacturer specifications.
-
Pulse Configuration: Set scaling (pulses per revolution or per unit flow).
-
Control Configuration: Configure PID or feedforward control loops in Toolbox ST.
-
Coating Verification: Inspect under UV (365 nm) upon receipt.
-
Compatibility: Fits all Mark VIe VME64x racks. Requires ControlST v6.0 or higher.
Operational Precautions
-
Wiring: Follow GE wiring diagrams—correct polarity and shield grounding essential.
-
Bridge Excitation: Verify excitation voltage does not exceed sensor manufacturer specifications.
-
Control Tuning: Perform PID tuning during commissioning—avoid overshoot and instability.
-
Calibration: Factory calibrated—verify against known references during commissioning.
-
LED Diagnostics: Green = normal; Amber = fault; Red = module fault.
-
Fault Log: Access 750-event log via Toolbox ST.
-
Coating Care: Use GE-approved cleaner; inspect annually under UV.
-
Hot-Swap: Remove/insert slowly under power.
-
Spare Stock: Maintain 1 spare per 3–4 racks.
-
ESD: Handle by edges with grounded wrist strap.
-
Storage: Anti-static bag with desiccant at –40 to +85 °C; rotate every 3 years.

Schneider 140CRA93200
GRANVILLE-PHILLIPS 360120
GRANVILLE-PHILLIPS 360120
BENTLY 1X35668