Description
Key Specifications
| Parameter | Specification |
|---|---|
| Bridge Sensor Inputs | 8 dedicated bridge sensor inputs (strain gauges, pressure transducers, load cells) |
| Bridge Excitation | Programmable (0.5 V, 1 V, 2.5 V, 5 V, 10 V) |
| Bridge Sensor Resolution | 24-bit ADC |
| Bridge Sensor Accuracy | ±0.03% of full scale |
| Pressure Inputs | 8 differential analog inputs (4–20 mA, 0–10 V) for pressure monitoring |
| Pressure Input Accuracy | ±0.05% of full scale |
| Pulse/Frequency Inputs | 4 high-speed pulse/frequency input channels |
| Pulse Input Range | 0.5 Hz to 100 kHz (improved over H1A) |
| Pulse Input Voltage | 100 mV to 100 V p-p (magnetic); 5–24 VDC (proximity/encoder) |
| Pulse Accuracy | ±0.005% of reading (improved over H1A) |
| Protection Functions | Over-pressure trip, over-speed trip, rate-of-change detection, redundant voting logic |
| Response Time | <5 ms for protection logic (fastest in BPPB series) |
| Isolation | 1500 VDC (I/O-to-backplane) |
| Diagnostics | 750-event fault log with timestamps and waveform snapshots |
| Communication | I/O Net (dual Ethernet ports for redundancy) |
| Form Factor | 6U VME64x (160 × 233 mm), single-slot width |
| Indicators | Per-channel LED (signal OK/fault), module health, protection status, communication status |
| Operating Temp | 0 °C to +60 °C |
| Power Draw | 16 W (+5 V / +3.3 VDC) |
| Connectors | Front-panel 48-pin terminal block with gold-plated contacts and captive washer screws |
Advantages & Distinctive Features
-
Dedicated Protection Module: Engineered for boiler and turbine protection with fast <5 ms response.
-
Comprehensive Bridge Sensor Support: 8 bridge inputs with programmable excitation for pressure, strain, and load measurement.
-
Pressure Monitoring: 8 analog inputs for direct pressure sensor connection.
-
High-Speed Pulse Inputs: 4 pulse/frequency channels for speed sensors, flowmeters, and encoders.
-
Fastest Response: <5 ms protection logic meets API 670 requirements.
-
Improved Accuracy: ±0.03% bridge accuracy and ±0.005% pulse accuracy.
-
Redundant Voting Logic: Supports 2-out-of-3 voting for critical protection functions.
-
On-Board Protection Logic: Reduces processor load for deterministic trip response.
-
Waveform Snapshots: Captures pre- and post-fault data for root-cause analysis.
-
Gold-Plated Captive Washer Terminals: Corrosion-resistant and vibration-proof.
-
Hot-Swappable: No rack power-down for replacement.
-
Direct Retrofit: Replaces older BPPB and BAPA series boards.
Application Fields
-
Boiler Protection: Pressure monitoring, drum level (bridge sensors), over-pressure trip
-
Gas Turbines: Speed measurement, pressure monitoring, overspeed protection
-
Steam Turbines: Speed measurement, pressure monitoring, overspeed protection
-
Compressors: Inlet/discharge pressure, speed monitoring, surge detection
-
Pressure Vessels: Over-pressure protection, load cell monitoring
-
Safety Systems: 2-out-of-3 voting for critical trips
Comparison with BAPAH1A and Competitors
| Feature | GE IS210BPPBH2B | GE IS210BAPAH1A | Competitor A | Competitor B |
|---|---|---|---|---|
| Bridge Inputs | 8 (with excitation) | 4 | None | None |
| Pressure Inputs | 8 | 4 (analog) | 8 (4-20mA) | 8 (4-20mA) |
| Pulse Inputs | 4 (100 kHz) | 4 (50 kHz) | None | 2 (50 kHz) |
| Protection Logic | <5 ms | No | No | No |
| Accuracy (bridge) | ±0.03% | ±0.05% | N/A | N/A |
| Voting Logic | Yes (2-out-of-3) | No | No | No |
| Waveform Snapshots | Yes | No | No | No |
Selection Guidelines
-
When to choose: Boiler and turbine protection applications requiring fast response, bridge sensors, pressure, and pulse inputs.
-
Bridge Configuration: Configure excitation voltage per manufacturer specifications.
-
Protection Logic: Configure trip setpoints and voting logic in Toolbox ST.
-
Pulse Configuration: Set scaling (pulses per revolution or per unit flow).
-
Compatibility: Fits all Mark VIe VME64x racks. Requires ControlST v6.5 or higher.
Operational Precautions
-
Wiring: Follow GE wiring diagrams—correct polarity and shield grounding essential.
-
Bridge Excitation: Verify excitation voltage does not exceed sensor manufacturer specifications.
-
Protection Testing: Simulate over-pressure and over-speed conditions to verify <5 ms trip response.
-
Voting Logic Testing: Simulate single-channel failures to verify 2-out-of-3 logic.
-
Calibration: Factory calibrated—verify against known references during commissioning.
-
LED Diagnostics: Green = normal; Amber = alert; Red = trip/fault.
-
Fault Log: Access 750-event log via Toolbox ST—review waveform snapshots.
-
Hot-Swap: Remove/insert slowly under power.
-
Spare Stock: Maintain 1 spare per 3–4 racks—critical for protection availability.
-
Firmware Updates: Ensure the GE IS210BPPBH2B is in “standby” mode during updates.
-
ESD: Handle by edges with grounded wrist strap.

BENTLY “330103-00-04-10-02-00 L=22MM) ”
WESTINGHOUSE 1C31203G01
BENTLY 330180-51-00