GE IS200VCCCH1B

¥999.00

IS200VCCCH1B is a Terminal Board within the GE Mark VIe Speedtronic control system, designed as a field termination and signal conditioning interface for redundant and critical analog input signals in turbine control applications. This board provides centralized termination for critical analog sensors such as speed probes, vibration sensors, pressure transmitters, temperature transmitters, and position transducers where high reliability and redundancy are required. The IS200VCCCH1B features integrated termination points with built-in signal conditioning including filtering, enhanced isolation, and diagnostics. It offers dual-redundant analog input channels with automatic failover and comprehensive diagnostics.

Category:

Description

Product Parameters

Parameter Specification
Brand / Series GE Mark VIe Speedtronic
Model IS200VCCCH1B
Redundant Analog Inputs 8 redundant pairs (16 total analog inputs)
Input Types 4–20 mA, 0–10 V, ±10 V (software-selectable per channel)
ADC Resolution 16-bit SAR (10–500 SPS)
Accuracy ±0.1% FS
Redundancy Logic Automatic failover (hardware-based)
Input Impedance 250 Ω (current mode), > 1 MΩ (voltage mode)
Filtering Programmable low-pass filter (1–50 Hz)
Loop Power 24 VDC (externally supplied only)
Isolation 1500 VAC (field-to-system)
CMRR >100 dB @ 50/60 Hz
Diagnostics Open-circuit detection, over/under-range detection, loop power fault monitoring, channel mismatch detection, primary/secondary status monitoring
Status Indication 8 green LEDs (primary active), 8 green LEDs (redundant active), 16 red LEDs (fault), 2 red summary fault LEDs
Operating Temperature –30°C to +65°C
Storage Temperature –55°C to +85°C
Mounting VME rack-mount terminal board with front-panel I/O connectors
Backplane Interface VME64x (A24/A32, D16/D32/D64)
EMC Compliance IEC 61000-4 Level 4

Advantages & Key Features

  • Redundant Analog InputsIS200VCCCH1B provides 8 redundant analog input pairs with automatic failover, ensuring uninterrupted critical signal monitoring.

  • High Channel Density: 8 redundant pairs (16 total inputs) in a single VME slot.

  • Flexible Input Configuration: Each channel supports 4–20 mA, 0–10 V, or ±10 V inputs via GE ToolboxST.

  • Comprehensive Diagnostics: Open-circuit, over/under-range, loop power fault, channel mismatch, and primary/secondary status monitoring per channel.

  • Opto-Isolation: 1500 VAC isolation protects the Mark VIe backplane from field wiring faults.

  • ToolboxST Integration: Full configuration, monitoring, and diagnostics via GE ToolboxST.

  • Drop-In Replacement: Direct replacement for earlier GE redundant analog input terminal boards.

Application Fields

  • Gas & Steam Turbines (GE Frame 6B/7EA/9E/HA): Redundant speed probes, critical pressure transmitters, critical temperature transmitters, vibration monitoring.

  • Combined Cycle Plants: Redundant HRSG pressure and temperature transmitters.

  • Compressor Stations: Redundant suction/discharge pressure transmitters.

  • Nuclear Power Plants: Critical analog monitoring where redundancy is mandated.

  • Safety-Critical Applications: Monitoring in safety instrumented systems (SIS).

Comparison with Competing Products

Feature GE IS200VCCCH1B Competitor A (Redundant Analog Module) Competitor B (Analog Input Module)
Redundant Pairs 8 (16 inputs) 4 (8 inputs) 0 (non-redundant)
Input Types 4–20 mA, 0–10 V, ±10 V 4–20 mA only 4–20 mA, 0–10 V
Diagnostics Open, over/under, loop power, mismatch, status Open only Open only
Isolation 1500 VAC 1000 VAC 500 VDC
Operating Temp –30°C to +65°C 0°C to 50°C 0°C to 60°C

Key AdvantageIS200VCCCH1B provides 8 redundant analog input pairs—double the density of competing redundant modules—with comprehensive diagnostics, making it ideal for critical turbine applications requiring high-reliability analog monitoring.

Selection Guidelines & Recommendations

  • Redundancy Configuration: Determine critical analog signals requiring redundant monitoring—up to 8 redundant pairs per board.

  • Input Type: Configure 4–20 mA, 0–10 V, or ±10 V per channel in GE ToolboxST.

  • Loop Power: External 24 VDC supplies required—plan cabinet power distribution accordingly.

  • Diagnostic Configuration: Enable mismatch detection and status monitoring for critical circuits.

  • Controller Firmware: Requires Mark VIe processor firmware v8.0 or later.

  • Wiring Guidelines: Use shielded twisted-pair cables for analog signal wiring.

  • Spare Strategy: Keep one spare per turbine; lead times 6–10 weeks.

  • Retrofit: Direct replacement—regenerate configuration in GE ToolboxST.

Important Cautions

  1. No Hot-Swap: De-energize rack before insertion/removal.

  2. Input Polarity: Observe correct polarity for 4–20 mA loops and voltage inputs.

  3. Loop Power: External 24 VDC required—ensure supplies are connected.

  4. Grounding: Connect AGND to Mark VIe system ground at single star point.

  5. Shield Termination: Ground signal cable shields only at cabinet end.

  6. ESD Handling: Use grounded wrist straps; field repair not possible.

  7. Redundancy Verification: Confirm both primary and secondary inputs are operational after installation.

  8. Channel Mapping: Verify field wiring maps to correct ToolboxST channel numbers.

AB 1747-L532
YASKAWA SGMPH-01A2A-YR11
FOXBORO FBM237
A-B 2711-K3A10L1

Reviews

There are no reviews yet.

Be the first to review “GE IS200VCCCH1B”

Your email address will not be published. Required fields are marked *