Description
Product Parameters
| Parameter | Specification |
|---|---|
| Brand / Series | GE Mark VIe Speedtronic |
| Model | IS200TRPSH1A |
| Power Channels | 8 isolated channels with series redundancy (16 total outputs) |
| Output Voltage | 24 VDC (regulated, programmable per channel) |
| Output Current | 50 mA per channel (400 mA total maximum) |
| Input Voltage Range | 24/48/125 VDC (auto-ranging, from Mark VIe rack) |
| Voltage Regulation | ±0.1% |
| Ripple/Noise | < 10 mV peak-to-peak |
| Redundancy Configuration | Series redundant (primary + secondary in series) |
| Redundancy Logic | Automatic failover (hardware-based, < 10 ms) |
| Isolation | 1500 VAC (channel-to-channel and field-to-system) |
| Diagnostics | Overcurrent detection, short-circuit detection, under/over-voltage monitoring, open-circuit detection, primary/secondary power status monitoring |
| Status Indication | 8 green LEDs (primary active), 8 green LEDs (redundant active), 16 red LEDs (fault), 2 red summary fault LEDs |
| Operating Temperature | –30°C to +65°C |
| Storage Temperature | –55°C to +85°C |
| Mounting | VME rack-mount terminal board with front-panel I/O connectors |
| Backplane Interface | VME64x (A24/A32, D16/D32/D64) |
| EMC Compliance | IEC 61000-4 Level 4 |
Advantages & Key Features
-
Series Redundant Configuration: IS200TRPSH1A provides 8 transducer power channels with series redundancy (primary + secondary in series), ensuring uninterrupted power to critical field devices.
-
High Reliability: Dual power sources per transducer with automatic failover.
-
High Channel Density: 8 channels with series redundancy (16 total outputs) in a single VME slot.
-
Programmable Output Voltage: Per-channel adjustable 24 VDC output via GE ToolboxST.
-
Comprehensive Diagnostics: Overcurrent, short-circuit, under/over-voltage, open-circuit, and power status monitoring.
-
Opto-Isolation: 1500 VAC isolation protects the Mark VIe backplane from field wiring faults.
-
ToolboxST Integration: Full configuration, monitoring, and diagnostics via GE ToolboxST.
-
Drop-In Replacement: Direct replacement for earlier GE series redundant transducer power terminal boards.
Application Fields
-
Gas & Steam Turbines (GE Frame 6B/7EA/9E/HA): Series redundant power for critical pressure transmitters (fuel gas, steam pressure), temperature transmitters, and position transducers.
-
Combined Cycle Plants: Series redundant power for HRSG critical pressure and temperature transmitters.
-
Compressor Stations: Series redundant power for critical suction/discharge pressure transmitters.
-
Safety-Critical Applications: Powering transducers in safety instrumented systems (SIS) requiring series redundancy.
Comparison with Competing Products
| Feature | GE IS200TRPSH1A | Competitor A (Redundant Power Module) | Competitor B (Power Supply Module) |
|---|---|---|---|
| Redundancy Type | Series redundant (8 channels) | Parallel redundant (4 pairs) | Non-redundant |
| Power Channels | 8 isolated | 4 isolated | 8 |
| Output Current | 50 mA/channel | 40 mA/channel | 50 mA/channel |
| Failover Time | < 10 ms hardware | < 50 ms software | N/A |
| Diagnostics | Overcurrent, short, under/over-voltage, open, status | Overcurrent only | Overcurrent only |
| Isolation | 1500 VAC | 1000 VAC | 500 VDC |
| Operating Temp | –30°C to +65°C | 0°C to 50°C | 0°C to 60°C |
Key Advantage: IS200TRPSH1A provides 8 series redundant transducer power channels with < 10 ms hardware failover and comprehensive diagnostics, making it ideal for critical turbine applications requiring high-reliability transducer power with series redundancy.
Selection Guidelines & Recommendations
-
Redundancy Type: Select series redundant configuration for applications requiring primary and secondary power sources in series.
-
Output Voltage: Configure per-channel output voltage (default 24 VDC) in GE ToolboxST.
-
Current Requirements: Verify each transducer’s current draw does not exceed 50 mA per channel.
-
Diagnostic Configuration: Enable overcurrent, short-circuit, and power status monitoring for critical transducers.
-
Controller Firmware: Requires Mark VIe processor firmware v8.0 or later.
-
Wiring Guidelines: Use shielded twisted-pair cables. Maintain shield grounding only at the Mark VIe cabinet end.
-
Spare Strategy: Keep one spare per turbine; lead times 6–10 weeks.
-
Retrofit: Direct replacement—regenerate configuration in GE ToolboxST.
Important Cautions
-
No Hot-Swap: De-energize rack before insertion/removal.
-
Power Polarity: Observe correct polarity for transducer connections—reverse polarity may damage field devices.
-
Current Limit: Do not exceed 50 mA per channel—overcurrent protection will trip and latch.
-
Short-Circuit: If a short is detected, the channel will latch off. Clear the fault and reset via GE ToolboxST.
-
Failover Testing: Test failover operation by simulating primary power loss—verify automatic switchover.
-
Grounding: Connect AGND to Mark VIe system ground at single star point.
-
Shield Termination: Ground transducer cable shields only at cabinet end.
-
ESD Handling: Use grounded wrist straps; field repair not possible.
-
Channel Mapping: Verify field wiring maps to correct ToolboxST channel numbers.
-
Redundancy Verification: Confirm both primary and secondary power sources are operational after installation.

A-B 1756-IF8
FOXBORO FBM242
A-B 1746-NIO4V
WESTINGHOUSE 1C31169G02