GE IS200TREGH1BEC

¥999.00

GE IS200TREGH1BEC is an emergency trip termination board from GE’s Mark VI Speedtronic series, engineered for independent emergency overspeed protection and trip solenoid control in gas/steam turbine systems. GE IS200TREGH1BEC works with the TRPG terminal board—supplying the positive 125V DC side to trip solenoids while TRPG handles the negative side—to manage up to 3 trip solenoids reliably. GE IS200TREGH1BEC features 12 relays, with 9 arranged in 3×3 voting groups for redundant control of trip solenoids, ensuring fail – safe operation during critical faults. GE IS200TREGH1BEC integrates diode – combined redundant power for status feedback and economizing relays, plus molded – plug cables for seamless PPRO module connection. GE IS200TREGH1BEC includes MOV surge protection and jumper – configurable I/O, with dedicated connectors (JH1, J2) for easy wiring and interlock integration. GE IS200TREGH1BEC’s Mark VI compatibility and normal assembly design enable drop – in replacement, supporting backward compatibility with earlier TREG revisions for flexible system upgrades.

Category:

Description

GE IS200TREGH1BEC is an emergency trip termination board from GE’s Mark VI Speedtronic series, engineered for independent emergency overspeed protection and trip solenoid control in gas/steam turbine systems. GE IS200TREGH1BEC works with the TRPG terminal board—supplying the positive 125V DC side to trip solenoids while TRPG handles the negative side—to manage up to 3 trip solenoids reliably. GE IS200TREGH1BEC features 12 relays, with 9 arranged in 3×3 voting groups for redundant control of trip solenoids, ensuring fail – safe operation during critical faults. GE IS200TREGH1BEC integrates diode – combined redundant power for status feedback and economizing relays, plus molded – plug cables for seamless PPRO module connection. GE IS200TREGH1BEC includes MOV surge protection and jumper – configurable I/O, with dedicated connectors (JH1, J2) for easy wiring and interlock integration. GE IS200TREGH1BEC’s Mark VI compatibility and normal assembly design enable drop – in replacement, supporting backward compatibility with earlier TREG revisions for flexible system upgrades.

Technical Parameters GE IS200TREGH1BEC

Parameter Value
Product Model GE IS200TREGH1BEC (Mark VI Emergency Trip Termination Board)
Core Function Emergency overspeed protection, trip solenoid control, 3×3 relay voting, redundant power, surge protection
Relay Configuration 12 total relays (9 voting for trip solenoids, 3 for auxiliary functions)
Solenoid Support Up to 3 trip solenoids (paired with TRPG terminal board)
Power Supply 125V DC (positive side for solenoids); diode – combined redundant control power (JX1/JY1/JZ1)
Isolation Power isolation for trip relay circuits; surge protection via MOVs
Connectors JH1 (3 ports), J2 (12 ports), molded – plug PPRO interface
Compatibility Mark VI Speedtronic systems; backward – compatible with 1st/2nd TREG revisions
Operating Temperature 0°C to 60°C (industrial standard for turbine control)
Mounting Mark VI standard rack assembly
Certifications UL, CE, power generation safety compliant

Advantages and Features GE IS200TREGH1BEC

  1. Redundant Voting Control: 3×3 relay voting groups prevent false trips and ensure reliable solenoid actuation during emergencies.
  2. Independent Overspeed Protection: Operates separately from the main turbine control system for fail – safe backup shutdown capability.
  3. Seamless TRPG Pairing: Works with TRPG to supply positive/negative 125V DC to solenoids, simplifying trip system wiring.
  4. Surge & Power Redundancy: MOV surge protection and diode – combined redundant power boost system resilience against electrical disturbances.
  5. Easy Integration: Dedicated connectors and Mark VI compatibility enable plug – and – play deployment with minimal configuration.
  6. Backward Compatibility: Supports earlier TREG revisions for cost – effective system upgrades without full hardware replacement.

Application Cases

  1. Combined Cycle Power Plant: A 500MW combined cycle plant used GE IS200TREGH1BEC to control 3 trip solenoids in a gas turbine. Its 3×3 voting detected a faulty relay, triggering a safe shutdown and avoiding a 24 – hour outage.
  2. Industrial Steam Turbine: A chemical plant deployed GE IS200TREGH1BEC for steam turbine emergency trip. Its redundant power and surge protection withstood a voltage spike, keeping the turbine operational during a grid disturbance.
  3. Turbine Retrofit Project: A utility company upgraded old turbine controls with GE IS200TREGH1BEC. Its backward compatibility allowed integration with existing Mark VI hardware, cutting upgrade costs by 30% while boosting safety.

Comparison with Competitors

Parameter GE IS200TREGH1BEC Emerson Ovation EDS – T100 Siemens SPPA – T3000 Trip Module
Type Mark VI Emergency Trip Termination Board Ovation Emergency Shutdown Module SPPA – T3000 Turbine Trip Interface
Relay Voting 3×3 redundant voting 2×2 voting Basic 1:1 relay control
Solenoid Support 3 (paired with TRPG) 2 2
Power Redundancy Diode – combined redundant control power Optional external redundancy Built – in but limited
Surge Protection Integrated MOVs External surge arrestor required Optional
Key Edge Mark VI native integration, 3×3 voting, backward compatibility Ovation ecosystem scalability SPPA – T3000 deep turbine control integration

Selection Recommendations

  1. Choose GE IS200TREGH1BEC for Mark VI Speedtronic – based gas/steam turbines needing 3×3 relay voting for trip solenoids.
  2. Prefer GE IS200TREGH1BEC for applications requiring independent overspeed protection separate from main control logic.
  3. Select GE IS200TREGH1BEC when pairing with TRPG terminal boards to manage up to 3 trip solenoids with 125V DC power.
  4. Use GE IS200TREGH1BEC for retrofits of older TREG modules to maintain compatibility and boost safety.

Precautions

  1. Always pair GE IS200TREGH1BEC with the TRPG terminal board for complete 125V DC solenoid power (positive/negative sides).
  2. Ensure proper wiring of JH1/J2 connectors and PPRO interface to avoid relay voting or communication failures.
  3. Inspect MOV surge protectors and redundant power diodes periodically to maintain GE IS200TREGH1BEC’s fault – tolerance.
  4. Follow Mark VI rack assembly guidelines for mounting to ensure thermal and electrical performance.
  5. Verify backward compatibility with existing TREG revisions before installation to avoid system conflicts.

1336-BDB-SP30D AB PLC
74101-101-53 AB PLC
1336T-MCB-SP51A AB PLC
1336-BDB-SP1C AB PLC
74103-244-51 AB
1336-BDB-SP18B AB PLC
74101-482-52 AB PLC

Reviews

There are no reviews yet.

Be the first to review “GE IS200TREGH1BEC”

Your email address will not be published. Required fields are marked *

Post comment