Description
Product Parameters
| Parameter | Specification |
|---|---|
| Brand / Series | GE Mark VIe Speedtronic |
| Model | IS200TREGH1B |
| Thermocouple Inputs | 16 redundant pairs (dual channels per measurement point) |
| Total Sensor Connections | 32 thermocouple inputs (configurable as redundant or independent) |
| Thermocouple Types | J, K, T, E, R, S, B (per-channel configurable via GE ToolboxST) |
| Input Range | ±100 mV |
| Cold-Junction Compensation | Dual redundant CJC sensors (accuracy ±0.3°C) — upgraded from ±0.5°C |
| ADC Resolution | 24-bit delta-sigma with programmable sampling rate (2–250 SPS) — upgraded from 4–200 SPS |
| Accuracy | ±0.05% of reading + ±0.5°C — upgraded from ±0.1% + ±1°C |
| Redundancy Logic | Hardware-based comparison and voting (programmable thresholds) |
| Isolation | 2000 VAC (field-to-system) — upgraded from 1500 VAC |
| CMRR | >110 dB @ 50/60 Hz — upgraded from >100 dB |
| Diagnostics | Open-circuit detection, short-circuit detection, dual CJC fault monitoring and auto-failover, channel mismatch detection, sensor drift detection, reference validation |
| Status Indication | 16 green LEDs (primary active), 16 green LEDs (redundant active), 16 red LEDs (mismatch fault), 2 red summary fault LEDs, 1 yellow LED (reference/calibration status), 1 blue LED (CJC redundancy active) |
| Operating Temperature | –40°C to +70°C — upgraded from –30°C to +65°C |
| Storage Temperature | –55°C to +85°C |
| Mounting | VME rack-mount terminal board with front-panel I/O connectors |
| Backplane Interface | VME64x (A24/A32, D16/D32/D64) |
| EMC Compliance | IEC 61000-4 Level 4 |
Advantages & Key Features
-
Redundant Temperature Monitoring: IS200TREGH1B provides 16 redundant thermocouple pairs (32 total inputs) with hardware-based comparison and voting logic, ensuring safe and reliable temperature monitoring.
-
High Channel Density: 16 redundant measurement points (32 thermocouple inputs) in a single VME slot.
-
Superior Accuracy: ±0.05% reading + ±0.5°C with dual CJC sensors (±0.3°C) provides higher measurement precision.
-
Dual-Redundant CJC: Two independent cold-junction sensors with automatic cross-validation and failover ensure uninterrupted measurement accuracy.
-
Extended Temperature Range: –40°C to +70°C operation makes IS200TREGH1B suitable for extreme environments.
-
Enhanced Isolation: 2000 VAC isolation and >110 dB CMRR provide superior protection.
-
Flexible Configuration: Channels can be configured as redundant pairs or independent single-ended inputs via GE ToolboxST.
-
24-Bit Delta-Sigma Conversion: High-resolution ADC delivers stable, noise-free readings.
-
Redundancy Logic: Programmable mismatch thresholds and voting logic per channel pair.
-
Comprehensive Diagnostics: Open-circuit, short-circuit, dual CJC auto-failover, channel mismatch, sensor drift, and reference validation.
-
ToolboxST Integration: Full configuration, monitoring, and diagnostics via GE ToolboxST.
-
Drop-In Replacement: Direct replacement for IS200TREGH1A and earlier redundant thermocouple terminal boards.
Application Fields
-
Gas & Steam Turbines (GE Frame 6B/7EA/9E/HA): Exhaust gas temperature (EGT) monitoring with dual-redundant thermocouples per measurement point.
-
Turbine Inlet Temperature (TIT): Redundant temperature monitoring for critical combustion control.
-
Combined Cycle Plants: Redundant temperature monitoring for HRSG superheaters and reheat sections.
-
Nuclear Power Plants: Critical temperature monitoring where redundancy is mandated.
-
Aeroderivative Turbines: Redundant exhaust temperature monitoring.
-
Arctic & Desert Installations: Extreme-environment critical temperature monitoring.
Comparison with Competing Products
| Feature | GE IS200TREGH1B | GE IS200TREGH1A | Competitor A (Redundant TC Module) | Competitor B (Standard TC Module) |
|---|---|---|---|---|
| Redundant Pairs | 16 (32 inputs) | 16 (32 inputs) | 8 (16 inputs) | 0 (non-redundant) |
| CJC Accuracy | ±0.3°C (dual redundant) | ±0.5°C (single) | ±1.2°C | ±0.5°C |
| CJC Redundancy | Yes (auto-failover) | No | No | No |
| Accuracy | ±0.05% + ±0.5°C | ±0.1% + ±1°C | ±0.2% + ±2°C | ±0.1% + ±1°C |
| Sampling Rate | 2–250 SPS | 4–200 SPS | Fixed | 4–200 SPS |
| Isolation | 2000 VAC | 1500 VAC | 1000 VAC | 1000 VAC |
| Operating Temp | –40°C to +70°C | –30°C to +65°C | 0°C to 50°C | 0°C to 50°C |
| Reference Validation | Yes | No | No | No |
Key Advantage: IS200TREGH1B delivers 16 redundant thermocouple pairs with dual-redundant CJC (±0.3°C), superior accuracy (±0.05% + ±0.5°C), extended –40°C to +70°C temperature range, 2000 VAC isolation, and comprehensive diagnostics including reference validation and sensor drift detection—making it the premier solution for critical turbine temperature monitoring applications requiring maximum reliability and precision in extreme environments.
Selection Guidelines & Recommendations
-
Redundancy Configuration: Determine measurement points requiring redundant thermocouples—up to 16 redundant pairs.
-
Configuration Mode: Select redundant pair or independent single-ended mode per channel pair in GE ToolboxST.
-
Thermocouple Type: Supports J, K, T, E, R, S, and B.
-
Dual CJC Sensors: Automatic failover—blue LED indicates redundancy is active.
-
Mismatch Thresholds: Program acceptable temperature difference thresholds.
-
Controller Firmware: Requires Mark VIe processor firmware v8.5 or later.
-
Wiring Guidelines: Use shielded thermocouple extension-grade leads with correct polarity.
-
Spare Strategy: Keep one spare per turbine; lead times 8–12 weeks.
-
Retrofit: Direct replacement for IS200TREGH1A—regenerate configuration in GE ToolboxST.
Important Cautions
-
No Hot-Swap: De-energize rack before insertion/removal.
-
Thermocouple Polarity: Reverse connection produces negative readings—verify polarity.
-
CJC Protection: Do not apply conformal coating or tape over terminal block area.
-
Grounding: Connect AGND to Mark VIe system ground at single star point.
-
Shield Termination: Thermocouple shields ground only at cabinet end.
-
ESD Handling: Use grounded wrist straps; field repair not possible.
-
Temperature Rating: Verify cabinet ambient does not exceed +70°C or fall below –40°C.
-
Reference Validation: Yellow LED indicates reference drift—schedule factory recalibration if illuminated.
-
CJC Redundancy Status: Blue LED flashing indicates one CJC sensor failed—schedule service.
-
Channel Mapping: Verify field wiring maps to correct ToolboxST channel numbers.

SCHNEIDER 170AAI52040
FOXBORO FBM01
SCHNEIDER 140CPS11420


Reviews