Description
Product Parameters
| Parameter | Specification |
|---|---|
| Brand / Series | GE Mark VIe Speedtronic |
| Model | IS200TBAIH1B |
| Analog Inputs | 24 channels (4–20 mA, 0–10 V, ±10 V selectable) |
| ADC Resolution | 16-bit SAR with programmable sampling rate (10–500 SPS) |
| Accuracy | ±0.1% of full scale (25°C), ±0.2% over full temperature range |
| Loop Power | 24 VDC (externally supplied only — no internal loop power) |
| Input Impedance | 250 Ω (current mode), > 1 MΩ (voltage mode) |
| Filtering | Programmable low-pass filter (1–50 Hz) |
| Isolation | 1500 VAC (field-to-system) |
| CMRR | >100 dB @ 50/60 Hz |
| Diagnostics | Open-circuit detection, over-range/under-range detection, loop power fault monitoring |
| Status Indication | 24 green LEDs (channel active), 2 red LEDs (diagnostic fault summary) |
| Operating Temperature | –30°C to +65°C |
| Storage Temperature | –55°C to +85°C |
| Mounting | VME rack-mount terminal board with front-panel I/O connector |
| Backplane Interface | VME64x (A24/A32, D16/D32/D64) |
Advantages & Key Features
-
Higher Channel Density: 24 analog inputs in a single VME slot—50% more than IS200TBAIH1A and triple the density of competing 8-channel modules. Ideal for large turbines with extensive pressure, temperature, and flow monitoring.
-
Flexible Input Configuration: Each channel supports 4–20 mA, 0–10 V, or ±10 V inputs via GE ToolboxST software.
-
Programmable Filtering: Onboard low-pass filter (1–50 Hz) optimizes noise rejection vs. response speed.
-
Comprehensive Diagnostics: Real-time open-circuit, over-range/under-range, and loop power fault monitoring per channel.
-
Wide Input Compatibility: Accommodates both current and voltage sensors without external signal conditioners.
-
ToolboxST Integration: Full configuration, calibration, and diagnostics via GE ToolboxST.
-
Drop-In Replacement: Direct replacement for earlier GE analog input terminal boards.
Application Fields
-
Gas & Steam Turbines (GE Frame 6B/7EA/9E/HA): Fuel gas pressure/flow, steam pressure/temperature, bearing vibration (via transmitters), lube oil pressure/temperature, cooling water pressure, valve position feedback, generator hydrogen pressure.
-
Combined Cycle Plants: HRSG feedwater flow, steam drum pressure, superheater temperature, condensate flow, extraction pressure.
-
Compressor Stations: Suction/discharge pressure, gas flow, vibration transducers, intercooler temperature.
-
Aeroderivative Turbines: Fuel flow, engine oil pressure, inlet guide vane position, exhaust temperature transmitters.
Comparison with Competing Products
| Feature | GE IS200TBAIH1B | GE IS200TBAIH1A | Competitor A (Emerson) | Competitor B (Siemens) |
|---|---|---|---|---|
| Analog Inputs | 24 | 16 | 8 | 8 |
| Input Types | 4–20 mA, 0–10 V, ±10 V | 4–20 mA, 0–10 V, ±10 V | 4–20 mA only | 4–20 mA, 0–10 V |
| Accuracy | ±0.1% FS | ±0.1% FS | ±0.2% FS | ±0.15% FS |
| Isolation | 1500 VAC | 1500 VAC | 1000 VAC | 500 VDC |
| Operating Temp | –30°C to +65°C | –30°C to +65°C | 0°C to 50°C | 0°C to 60°C |
Key Advantage: IS200TBAIH1B provides 24 analog inputs—the highest channel density in its class and triple that of competing modules—with flexible input configuration and comprehensive diagnostics, significantly reducing rack space and simplifying system design for large turbine applications.
Selection Guidelines & Recommendations
-
Input Type: Configure 4–20 mA, 0–10 V, or ±10 V per channel in GE ToolboxST.
-
Loop Power: External 24 VDC supplies required—plan cabinet power distribution accordingly.
-
Filtering: Use 1–10 Hz for temperature/pressure, 20–50 Hz for dynamic signals.
-
Controller Firmware: Requires Mark VIe processor firmware v7.0 or later.
-
Spare Strategy: Keep one spare per turbine; lead times 6–10 weeks.
-
Retrofit: Direct replacement—regenerate configuration in GE ToolboxST for 24-channel mapping.
Important Cautions
-
No Hot-Swap: De-energize rack before insertion/removal.
-
External Loop Power Required: No internal loop power—ensure 24 VDC supplies are connected.
-
Input Overload: Sustained input >30 V or >50 mA may damage input circuitry.
-
Grounding: Connect AGND to Mark VIe system ground at single star point.
-
Shield Termination: Ground shields only at cabinet end.
-
ESD Handling: Use grounded wrist straps; field repair not possible.
-
Filtering Trade-Off: Lower cutoff = better noise rejection but more signal delay.
-
Channel Mapping: With 24 channels, verify wiring maps to correct ToolboxST channel assignments.
-
Power Supply Sizing: Ensure external 24 VDC supplies are sized for all connected transmitters (20–30 mA per channel × 24 channels = 0.48–0.72 A minimum).

A-B 1747-SN
GE IC697BEM713
WESTINGHOUSE 1C31234G01
A-B 1756-CNBR


Reviews