Description
Technical Specifications
| Parameter | Specification |
|---|---|
| Manufacturer | General Electric |
| Model | IS200RAPAG1A |
| Relay Functions | Relay coordination, trip monitoring, contact management |
| Alarm Functions | Alarm processing, annunciation, status indication |
| Protection Functions | Protection coordination, fault detection, system monitoring |
| Gateway Functions | Data routing, protocol conversion, system integration |
| Communication | Highway integration (GE proprietary) |
| Power | +5V DC / 2.0A, ±15V DC / 0.4A |
| Temp Range | -30°C to +65°C |
| MTBF | > 108,000 hours |
| Revision Note | “A” suffix = specific hardware/firmware configuration |
Advantages and Key Features
Dedicated Relay, Alarm, Protection, and Annunciator Gateway: The IS200RAPAG1A provides comprehensive relay, alarm, protection, and annunciator functions with gateway communication.
Relay Management: The IS200RAPAG1A handles relay coordination and contact management.
Alarm Processing: Provides alarm annunciation and status indication.
Protection Coordination: Fault detection and system monitoring.
Application Fields and Case Studies
Used in relay management systems, alarm annunciator applications, and protection coordination with gateway integration. In a 600 MW plant, the IS200RAPAG1A provided reliable relay, alarm, and protection management.
Comparison with Competing Products
| Dimension | IS200RAPAG1A | IS200PSCDG1ADB | IS200ERBPG1ACA |
|---|---|---|---|
| Primary Function | Relay/alarm/protection gateway | Power supply + control data gateway | Relay/breaker protection |
| Alarm Functions | Yes | No | Limited |
| Annunciator | Yes | No | No |
| VME Integration | Direct | Direct | Direct |
Selection Recommendations
Choose IS200RAPAG1A for relay, alarm, protection, and annunciator gateway applications. Verify compatibility with your specific relay, alarm, and protection requirements. Deploy for comprehensive alarm and protection management.
Precautions and Important Notes
Use ESD-safe handling. Verify field wiring and connections. Confirm compatibility with your specific relay, alarm, and protection requirements. Never interrupt firmware updates. Board draws 2.0A – verify rack power capacity. Document all configurations. Store spares in anti-static packaging. Do not mix variants in redundant pairs. Allow 30 seconds boot time. Test all relay, alarm, protection, and gateway functions during commissioning. The IS200RAPAG1A is critical for alarm and protection management – ensure all settings are verified before placing in service. Ensure communication cabling does not exceed maximum recommended length. Regular verification of alarm and protection performance is recommended.

Schneider 140AVO02000
HONEYWELL FS-SICC-0001/L3
ABB CI840A


Reviews
There are no reviews yet.