Description
Technical Specifications
| Parameter | Specification |
|---|---|
| Manufacturer | General Electric |
| Model | IS200JPDDG1A |
| Pulse Inputs | 4–8 pulse inputs (J-type, speed, flow, position sensors) |
| Pulse Data Distribution | Data routing, distribution to multiple destinations, fan-out |
| J-Type Gateway Functions | Data routing, protocol conversion, gateway communication |
| Supported Protocols | Modbus RTU, GE pulse protocols, J-type protocols |
| Communication | J-type serial interfaces, highway integration |
| Power | +5V DC / 2.0A, ±15V DC / 0.4A |
| Temp Range | -30°C to +65°C |
| MTBF | > 108,000 hours |
| Revision Note | “A” suffix = specific hardware/firmware configuration |
Advantages and Key Features
Dedicated J-Gateway Pulse Data Distribution: The IS200JPDDG1A provides specialized pulse data distribution and J-type gateway communication.
Pulse Data Distribution: The IS200JPDDG1A routes pulse data to multiple destinations.
J-Type Gateway Functions: Enables data routing and protocol conversion.
Application Fields and Case Studies
Used in pulse data distribution applications, J-type network integration, and gateway communication for pulse data. In a 600 MW plant, the IS200JPDDG1A provided reliable J-gateway pulse data distribution.
Comparison with Competing Products
| Dimension | IS200JPDDG1A | IS200JPDCG1A | IS200JPDBG2ABB |
|---|---|---|---|
| Primary Function | Pulse data distribution | Pulse data conversion | Pulse data bridge |
| Data Distribution | Yes | No | No |
| VME Integration | Direct | Direct | Direct |
Selection Recommendations
Choose IS200JPDDG1A for pulse data distribution and J-type gateway applications. Verify compatibility with your specific pulse sensors and distribution requirements. Deploy for multi-destination data routing applications.
Precautions and Important Notes
Use ESD-safe handling. Verify field wiring and pulse connections. Confirm compatibility with your specific pulse sensors and distribution requirements. Never interrupt firmware updates. Board draws 2.0A – verify rack power capacity. Document all configurations. Store spares in anti-static packaging. Do not mix variants in redundant pairs. Allow 30 seconds boot time. Test all distribution and gateway functions during commissioning. The IS200JPDDG1A is critical for pulse data distribution – ensure all settings are verified before placing in service. Ensure proper shielding for pulse signals to avoid noise interference. Regular verification of pulse data quality and distribution performance is recommended. Ensure communication cabling does not exceed maximum recommended length.

WESTINGHOUSE 1C31234G01
A-B 1769-AENTR
TRICONEX HCU3700/3703E
FOXBORO FBM203


Reviews