Description
Technical Specifications
| Parameter | Specification |
|---|---|
| Manufacturer | General Electric |
| Model | IS200DVIBH1BAB |
| Series | Mark VI / Speedtronic™ |
| Board Type | Digital Vibration Input (DVIB) |
| Input Channels | 8 isolated vibration inputs |
| Supported Sensor Types | Accelerometers (IEPE/charge), proximity probes (eddy current) |
| Input Range | ±10V (software configurable) |
| Resolution | 16-bit ADC per channel |
| Frequency Range | 0.5 Hz to 10 kHz (software selectable filtering) |
| Integration Options | Displacement (μm), Velocity (mm/s), Acceleration (g) – software selectable |
| Signal Conditioning | Built-in IEPE excitation (4 mA constant current) |
| Filtering | Low-pass, high-pass, and band-pass (software configurable) |
| Update Rate | 10 ms per channel (sequential) |
| Isolation | Channel-to-channel and channel-to-backplane: 1500V RMS |
| Power Requirements | +5V DC / 2.5A, ±15V DC / 0.5A |
| Operating Temperature | -30°C to +65°C |
| Suffix Meaning | “AB” = specific firmware/configuration variant with presets |
Advantages and Key Features
Factory-Preconfigured Filtering Presets: The IS200DVIBH1BAB ships with application-specific filter presets matching common turbine vibration frequencies (e.g., 1X, 2X, or sub-synchronous), reducing on-site commissioning time and eliminating manual filter tuning errors.
Integrated IEPE Excitation: Provides built-in constant current excitation (4 mA) for IEPE accelerometers, eliminating the need for external signal conditioners.
Software-Selectable Integration: Each channel can be independently configured to output displacement, velocity, or acceleration, providing flexibility for different monitoring requirements.
Advanced Diagnostics: Includes sensor fault detection (open-circuit, short-circuit), signal range validation, and DC bias monitoring with fault reporting to the main DSP processor.
Real-Time Monitoring: With a 10 ms update rate, captures transient vibration events critical for turbine trip protection.
Application Fields and Case Studies
The IS200DVIBH1BAB is used in GE gas and steam turbines for shaft relative vibration monitoring (proximity probes), bearing absolute vibration monitoring (accelerometers), and compressor surge detection. In a 600 MW combined-cycle plant, the IS200DVIBH1BAB was selected for its factory-preloaded filter presets matching the site’s specific turbine rotor dynamics. The presets eliminated manual filter tuning and reduced commissioning time by 2 days. During a startup transient, the IS200DVIBH1BAB detected a sudden increase in sub-synchronous vibration, allowing operators to adjust fuel scheduling before reaching critical levels.
Comparison with Competing Products
| Dimension | IS200DVIBH1BAB | IS200DVIBH1B | Siemens SM 341 | ABB VIB-8 |
|---|---|---|---|---|
| Input Channels | 8 | 8 | 4 | 8 |
| Sensor Types | IEPE/Proximity | IEPE/Proximity | IEPE only | IEPE/Proximity |
| Integration Options | D/V/A all selectable | D/V/A all selectable | V/A only | D/V/A all selectable |
| Filtering | Programmable + presets | Programmable | Fixed | Programmable |
| Pre-configured Presets | Yes (AB) | No | No | Limited |
| Update Rate | 10 ms | 10 ms | 20 ms | 15 ms |
| Diagnostics | Open + short + bias | Open + short + bias | Limited | Open + short |
The IS200DVIBH1BAB offers the same high performance as the IS200DVIBH1B with the added benefit of factory-preconfigured filter presets that reduce setup time and eliminate tuning errors. This makes it particularly valuable for standardized turbine packages.
Selection Recommendations
Choose the IS200DVIBH1BAB when your project involves GE turbines with known vibration characteristics and the “AB” presets match your application. Use it as a replacement for IS200DVIBH1B boards when you require reduced commissioning effort and consistent filter settings. Select the appropriate sensor type (accelerometer or proximity probe) based on your application. Deploy multiple IS200DVIBH1BAB boards to cover all vibration measurement points. For critical turbines, use redundant IS200DVIBH1BAB boards with sensors wired to both boards. Avoid the IS200DVIBH1BAB if your vibration frequencies differ from the preloaded presets; use a standard IS200DVIBH1B and configure filters manually.
Precautions and Important Notes
Always use ESD-safe handling procedures when installing the IS200DVIBH1BAB. Verify that the preloaded “AB” filter presets match your specific turbine vibration frequencies. Use properly shielded coaxial or twisted-pair cables for sensor wiring. Ensure correct sensor wiring configuration (IEPE vs. proximity) to avoid damage. Verify that the excitation current (4 mA) is appropriate for your IEPE sensors. Configure filters appropriately to avoid aliasing. Allow the IS200DVIBH1BAB to stabilize for 30 minutes after power-up before relying on readings. When replacing a IS200DVIBH1B with a IS200DVIBH1BAB, verify configuration settings in ToolboxST. Do not mix IS200DVIBH1BAB with standard IS200DVIBH1B in redundant pairs without confirming identical settings. Store spare boards in anti-static packaging and rotate inventory every 24 months. Consult GE engineering when using the IS200DVIBH1BAB with non-standard sensors or vibration frequencies not covered by the presets.

MKS 20275-498
“WESTINGHOUSE
” 1C31234G01
A-B 1756-ENBT


Reviews