GE IS200DSVOH2BDB

¥999.00

The IS200DSVOH2BDB is a Digital Signal Voltage Output (DSVO) board from General Electric’s Mark VI Speedtronic™ series. This model combines the 16-channel high-density architecture of the IS200DSVOH2B with the “DB” suffix configuration, indicating a specific firmware preload, enhanced diagnostic firmware, and application-tailored settings for advanced turbine control applications. The IS200DSVOH2BDB is designed for complex multi-actuator systems requiring both high channel count and specialized configuration, such as combined-cycle plants with multiple fuel staging valves, steam admission and extraction valves, and IGV controls. It features 16 isolated 16-bit analog voltage output channels with ±10V/0–10V range, 1500V isolation per channel, and enhanced onboard diagnostics. The “DB” designation typically signifies factory configuration for specific actuator families with pre-set scaling and calibration parameters, reducing commissioning effort. The board mounts directly into a Mark VI VME backplane and interfaces with the main DSP processor for precise actuator positioning commands.

Category:

Description

Technical Specifications

Parameter Specification
Manufacturer General Electric
Model IS200DSVOH2BDB
Series Mark VI / Speedtronic™
Board Type Digital Signal Voltage Output (DSVO)
Output Channels 16 isolated analog voltage outputs
Output Range ±10V DC or 0–10V DC (software configurable)
Resolution 16-bit DAC per channel
Accuracy ±0.1% of full scale (typical)
Update Rate 1 ms per channel (sequential)
Output Current ±10 mA per channel (short-circuit protected)
Isolation Channel-to-channel and channel-to-backplane: 1500V RMS
Power Requirements +5V DC / 3.0A, ±15V DC / 1.0A
Operating Temperature -30°C to +65°C
Suffix Meaning “DB” = enhanced diagnostics + specific firmware preload

Advantages and Key Features

High Channel Density with Advanced Diagnostics: The IS200DSVOH2BDB provides 16 fully isolated channels with per-channel diagnostics including open-circuit, short-circuit, output deviation, and response-time monitoring – more comprehensive than the standard IS200DSVOH2B or IS200DSVOH1A.

Factory-Preloaded Actuator Parameters: The “DB” configuration on the IS200DSVOH2BDB includes pre-set scaling, calibration curves, and fault thresholds for common GE actuator types, reducing field commissioning time by up to 60%.

Enhanced Fault Logging: The IS200DSVOH2BDB features extended onboard event logging with 1 ms timestamp resolution, capturing output deviations and channel status changes for root-cause analysis of turbine trips.

Robust Power Regulation: Like the IS200DSVOH2B, this board incorporates upgraded voltage regulators providing clean power to all 16 DACs, ensuring low output ripple even under full channel load.

Redundancy-Ready: Supports dual-board hot-standby configuration with automatic failover, ensuring uninterrupted actuator control for critical paths.

Application Fields and Case Studies

The IS200DSVOH2BDB is used in large combined-cycle plants, multi-shaft turbine installations, and applications requiring high-density actuator control with advanced diagnostics. In a 900 MW European combined-cycle plant, the IS200DSVOH2BDB was selected to control 16 actuators across two gas turbines and one steam turbine. The “DB” preload matched the site’s specific electro-hydraulic actuators, reducing commissioning from 5 days to 2 days. When a fuel valve actuator developed a slow response due to mechanical wear, the IS200DSVOH2BDB diagnostics detected output deviation against the command signal and alerted operators before the condition could affect turbine stability.

Comparison with Competing Products

Dimension IS200DSVOH2BDB IS200DSVOH2B Siemens SM 332 (16 ch) ABB AO820
Output Channels 16 16 16 16
Resolution 16-bit 16-bit 14-bit 16-bit
Isolation 1500V RMS per channel 1500V RMS per channel 500V RMS 1500V RMS
Update Rate 1 ms 1 ms 2 ms 1 ms
Diagnostics Advanced per-channel + logging Standard per-channel Limited Per-channel
Pre-configured Options Yes (DB) No Limited Limited
MTBF > 95,000 hrs > 95,000 hrs ~85,000 hrs ~100,000 hrs

The IS200DSVOH2BDB offers the most comprehensive diagnostics among 16-channel analog output boards, with advanced logging and pre-configured actuator parameters that significantly reduce commissioning time. The standard IS200DSVOH2B is suitable when advanced diagnostics are not required. Siemens and ABB alternatives lack the specific GE actuator pre-configuration and diagnostic depth of the IS200DSVOH2BDB.

Selection Recommendations

Choose the IS200DSVOH2BDB for large turbine control projects requiring 16 voltage outputs with advanced diagnostics and pre-configured actuator matching. Select it over the standard IS200DSVOH2B when your system requires detailed fault logging and response-time monitoring for critical actuators. Deploy redundant IS200DSVOH2BDB boards for combined-cycle plants where actuator failure could trigger turbine trips. Verify that your actuators match the “DB” preload configuration; consult GE documentation for specific actuator model compatibility. For simpler applications with standard diagnostics requirements, the IS200DSVOH2B offers a more cost-effective solution.

Precautions and Important Notes

Always use ESD-safe handling procedures when installing the IS200DSVOH2BDB. Ensure the rack power supply can deliver the required +5V (3.0A) and ±15V (1.0A) current. Never connect outputs to 4–20 mA current-loop actuators without proper conversion. Verify that the preloaded “DB” configuration matches your specific actuator scaling; incorrect parameters can cause unsafe operation. When replacing a IS200DSVOH2B with a IS200DSVOH2BDB, reconfigure ToolboxST channel mapping to utilize the enhanced diagnostics features. Do not mix IS200DSVOH2BDB with IS200DSVOH2B in a redundant pair – identical models are required for proper failover. Document all channel-to-actuator wiring before board removal. Store spare boards in anti-static packaging and rotate inventory every 24 months. Consult GE engineering when repurposing the IS200DSVOH2BDB for non-standard actuator types or actuator models not covered by the “DB” preload.

“WESTINGHOUSE
” 1C31234G01
WESTINGHOUSE 1C31234G01
A-B 1756-ENBT

Reviews

There are no reviews yet.

Be the first to review “GE IS200DSVOH2BDB”

Your email address will not be published. Required fields are marked *