GE IS200AEADH4ADA

¥1,599.00

The GE IS200AEADH4ADA is a high-density analog input module designed for the GE Mark VIe Speedtronic Turbine Control System. This module is part of the distributed I/O architecture of the Mark VIe, classified as a “Termination Board” or “I/O Pack.” The primary function of the GE IS200AEADH4ADA is to interface with a large number of field-mounted analog transmitters (typically 4-20mA or 0-10V) that monitor critical process parameters. It conditions, digitizes, and transmits these signals to the triple modular redundant (TMR) controllers within the Mark VIe system for processing in control and protection algorithms. Installed in a designated I/O pack slot, this module is essential for gathering data such as temperatures, pressures, flows, and levels from around the turbine and its auxiliary systems.

Category:

Description

GE IS200AEADH4ADA – Analog Input Module for Mark VIe System

Product Description
The GE IS200AEADH4ADA is a high-density analog input module designed for the GE Mark VIe Speedtronic Turbine Control System. This module is part of the distributed I/O architecture of the Mark VIe, classified as a “Termination Board” or “I/O Pack.” The primary function of the GE IS200AEADH4ADA is to interface with a large number of field-mounted analog transmitters (typically 4-20mA or 0-10V) that monitor critical process parameters. It conditions, digitizes, and transmits these signals to the triple modular redundant (TMR) controllers within the Mark VIe system for processing in control and protection algorithms. Installed in a designated I/O pack slot, this module is essential for gathering data such as temperatures, pressures, flows, and levels from around the turbine and its auxiliary systems.

Product Parameters

  • Type: High-Density Analog Input Module.

  • System: GE Mark VIe Turbine Control System.

  • Module Designation: Often referred to as an “AEAD” series module.

  • Input Channels: Typically provides 16 single-ended or 8 differential analog input channels (exact count to be verified by the H4ADA suffix).

  • Input Signal Types: Configurable per channel for current (e.g., 4-20mA) or voltage (e.g., 0-10V) inputs. Likely includes built-in precision resistors for current loop measurement.

  • Resolution: High-resolution analog-to-digital conversion (e.g., 16-bit).

  • Accuracy: High accuracy suitable for critical process measurement (e.g., ±0.1% of full scale).

  • Isolation: Channel-to-channel and channel-to-system isolation to prevent ground loops and ensure signal integrity in electrically noisy environments.

  • Diagnostics: Includes continuous diagnostics for channel faults such as open circuit (broken wire), over-range, and under-range conditions.

  • Communication: Interfaces with the Mark VIe controller via a high-speed backplane bus (VME or proprietary).

  • Configuration: Module parameters (range, filtering, alarm limits) are configured using the GE ToolboxST engineering software.

Advantages and Features

  • High Channel Density: The GE IS200AEADH4ADA consolidates a large number of analog signals into a single module, optimizing space in the I/O cabinet and reducing the number of modules required for a typical turbine application.

  • Integrated Signal Conditioning: Provides built-in conditioning for direct connection to field transmitters, eliminating the need for external signal isolators or transducers in most cases.

  • Critical Diagnostics: The continuous broken wire and out-of-range detection allows the control system to identify sensor failures promptly, enabling alerts and potentially initiating safe backup control strategies.

  • Designed for TMR Systems: As part of the Mark VIe, it is engineered for high reliability and supports the system’s fault-tolerant architecture, often with modules installed in triplicate for critical measurements.

  • Hot-Swap Capable: Designed to allow replacement without requiring a turbine shutdown, following proper procedures, which is crucial for plant availability.

  • Seamless ToolboxST Integration: Full configuration, calibration, and diagnostics are managed within the standard GE engineering software environment.

Application Cases in Various Fields

  • Gas & Steam Turbine Power Plants: Primary application. The GE IS200AEADH4ADA module is used to monitor hundreds of points: lube oil temperature/pressure, fuel gas pressure, exhaust temperature (via thermocouples through transmitters), compressor discharge pressure, and various valve positions.

  • Compressor Stations (Oil & Gas): Monitoring suction and discharge pressures, temperatures, flows, and vibration signals (converted to 4-20mA) on turbine-driven compressors.

  • Marine Propulsion: Used in control systems for marine gas turbines, monitoring engine parameters and ship system inputs.

Comparisons with Competing Products

  • Other Mark VIe I/O Modules: Within the Mark VIe system, it differs from other modules like the IS200AEAX (thermocouple input) or IS200AEAG (RTD input). The AEAD series is specifically for standard analog voltage/current signals.

  • Competing Turbine Control Systems (Emerson, Siemens): Competitors like Emerson (Ovation) and Siemens have their own proprietary analog input cards. The IS200AEADH4ADA is not interchangeable and is a core component of the GE ecosystem.

  • Generic PLC Analog Input Cards: Standard PLC cards from Allen-Bradley or Siemens offer similar functionality but lack the specific form factor, diagnostic depth, and direct engineering integration for critical turbine protection that the Mark VIe-specific AEAD module provides.

Selection Suggestions and Precautions

  1. System Compatibility is Absolute: The GE IS200AEADH4ADA is only for use in specific Mark VIe I/O packs. Verify the exact I/O pack model and controller compatibility. Using it in an incompatible slot will cause system errors.

  2. Decode the Suffix Carefully: The H4ADA suffix defines critical hardware characteristics (channel count, input types, voltage ratings). Confirm this matches the signals you need to connect. A different suffix (e.g., H1ADA) may have different specs.

  3. Proper Field Wiring Practices: Use shielded, twisted-pair cables for analog signals. Ground the shield at one end only (typically in the marshalling cabinet) to prevent noise. Adhere to specified wire gauges and terminal torque settings.

  4. Configuration is Mandatory: Each channel on the new or replacement module must be configured in ToolboxST for the correct signal type (mA/V), range, scaling, and alarm limits. Simply swapping hardware without loading the configuration will not work.

  5. Calibration Considerations: While the module is highly accurate, critical loops may require periodic calibration. This involves applying known mA or V signals and verifying/trimming the reading in ToolboxST.

  6. Observe ESD and Handling Procedures: Handle the module as static-sensitive equipment. Follow GE’s procedures for insertion, removal, and storage to prevent damage to sensitive electronics.

IC693PBS105G GE PLC
IC693PCM301M DCS
IC693ALG221 GE PLC
IC693ALG442 GE PLC
IC693CPU364-CF DCS

Reviews

There are no reviews yet.

Be the first to review “GE IS200AEADH4ADA”

Your email address will not be published. Required fields are marked *