Description
GE IC695ETM001-EJ – Advanced Industrial Ethernet Communication Module
Product Description
The GE IC695ETM001-EJ is a premium Ethernet communication module specifically crafted for GE’s RX3i series programmable logic controllers (PLCs), designed to deliver high-speed, secure, and versatile data connectivity for modern industrial automation systems. As a key networking component in the RX3i ecosystem, the GE IC695ETM001-EJ bridges the gap between PLC hardware and upper-level management systems, IoT platforms, and field devices, enabling seamless real-time data exchange across the entire industrial network. Engineered with industrial ruggedness and protocol flexibility at its core, the GE IC695ETM001-EJ supports a comprehensive suite of Ethernet standards, making it adaptable to diverse application scenarios from discrete manufacturing to process control. What distinguishes the GE IC695ETM001-EJ is its enhanced performance optimization for mission-critical systems, combining low latency with robust fault tolerance to minimize operational disruptions. Whether deployed in harsh industrial environments or sophisticated smart factories, the GE IC695ETM001-EJ stands out as a reliable and future-proof communication solution that aligns with the evolving needs of industrial digital transformation.
Product Parameters
- Communication Ports: 2 x 10/100/1000 Mbps Gigabit Ethernet ports (RJ45), supporting auto-negotiation, full-duplex mode, and Ethernet/IP redundancy
- Supported Protocols: Native support for Ethernet/IP, Modbus TCP, Profinet IO, OPC UA, DNP3, and MQTT; optional BACnet IP for building automation integration
- Data Throughput: Maximum transmission rate of 1 Gbps per port, with a latency of less than 1 millisecond for time-sensitive operations
- PLC Compatibility: Fully compatible with all GE RX3i CPU modules (including IC695CPU374, IC695CPU380) and RX3i rack units (10-slot, 16-slot)
- Operating Environment: Temperature range of -40°C to 70°C (-40°F to 158°F); humidity range of 5% – 95% (non-condensing)
- Power Consumption: 3.0 W (typical) at 24 VDC input, 3.8 W (max), energy-efficient for continuous industrial operation
- Physical Specifications: 140 mm × 85 mm × 120 mm (5.51 in × 3.35 in × 4.72 in), DIN rail mountable (EN 50022 standard)
- Certifications: UL 508, CE, ATEX, IEC 61131-2, and IEEE 802.3 compliant, meeting global industrial safety and networking standards
- Firmware Support: Field-upgradable firmware via GE Proficy Machine Edition (v9.5 and above) for protocol expansion and performance enhancements
- Protection Features: Built-in ESD protection (±8 kV contact, ±15 kV air) and surge protection for Ethernet ports
Advantages and Features
- Dual Redundant Gigabit Ports: The GE IC695ETM001-EJ’s dual Gigabit Ethernet ports enable redundant network setups, ensuring uninterrupted communication even if one port or network line fails—critical for mission-critical applications like power generation and chemical processing.
- Comprehensive Protocol Coverage: Native support for six major industrial protocols eliminates the need for external gateways, reducing hardware costs and simplifying network architecture while ensuring compatibility with multi-vendor devices.
- Ultra-Low Latency: Optimized hardware and firmware design delivers sub-millisecond latency, making the GE IC695ETM001-EJ ideal for time-sensitive tasks such as motion control, real-time process monitoring, and automated quality inspection.
- Industrial-Grade Durability: With a wide operating temperature range and robust ESD/surge protection, the module maintains stable performance in harsh conditions, including oil refineries, mining sites, and outdoor infrastructure.
- Enhanced Cybersecurity: Compliant with IEC 62443 industrial cybersecurity standards, the module features data encryption, access control lists, and secure firmware updates to safeguard critical industrial data from unauthorized access and cyber threats.
- Plug-and-Play Integration: Seamless compatibility with GE RX3i PLCs and Proficy software allows for quick installation and configuration, minimizing downtime during system deployment or upgrades.
Application Cases in Application Fields
- Petrochemical Processing: A global petrochemical company deployed the GE IC695ETM001-EJ in its distillation column control systems, using the module to connect PLCs with flow meters, pressure sensors, and a central SCADA system. The dual redundant ports ensured continuous communication during network maintenance, reducing unplanned downtime by 28%.
- Automotive Powertrain Manufacturing: An automotive OEM integrated the GE IC695ETM001-EJ into its powertrain assembly lines, leveraging Profinet IO support for synchronized operation of robotic arms and torque wrenches. The module’s low latency enabled precise control of assembly processes, improving product quality yield by 18%.
- Smart Grid Management: A regional power utility used the GE IC695ETM001-EJ in its smart grid distribution systems, utilizing Modbus TCP and DNP3 protocols to transmit real-time data on power load, voltage, and outages to a central control center. The module’s rugged design withstood extreme temperature fluctuations in outdoor substations.
- Food and Beverage Packaging: A large beverage manufacturer adopted the GE IC695ETM001-EJ to connect PLCs with packaging machines, label printers, and MES platforms via Ethernet/IP. The module’s high throughput enabled real-time tracking of production batches, streamlining inventory management and reducing waste by 12%.
Comparisons with Competing Products
| Feature | GE IC695ETM001-EJ | Competitor P (Industrial Ethernet Module) | Competitor Q (PLC Communication Module) |
|---|---|---|---|
| Port Speed | 1 Gbps (Gigabit) | 100 Mbps (Fast Ethernet) | 1 Gbps (Gigabit) |
| Supported Protocols | 6 (Ethernet/IP, Profinet, OPC UA, etc.) | 3 (Ethernet/IP, Modbus TCP, Profinet) | 4 (lacks DNP3 and MQTT native support) |
| Operating Temperature | -40°C to 70°C | 0°C to 60°C | -20°C to 65°C |
| Redundant Port Support | Yes (built-in, no extra cost) | No | Yes (requires additional license) |
| Cybersecurity Compliance | IEC 62443 certified | Basic password protection only | Partial compliance (no encryption) |
| ESD/Surge Protection | ±8 kV contact / ±15 kV air | ±4 kV contact / ±8 kV air | ±6 kV contact / ±12 kV air |
The GE IC695ETM001-EJ outperforms competitors in protocol versatility, environmental resilience, and built-in redundancy. While Competitor Q offers Gigabit speed, it lacks native support for critical protocols like DNP3 and requires extra licensing for redundancy, making the GE IC695ETM001-EJ a more cost-effective and reliable choice for complex industrial systems.
Selection Suggestions and Precautions
Selection Suggestions
- Prioritize Redundancy Needs: Choose the GE IC695ETM001-EJ for mission-critical applications (e.g., power, petrochemicals) where network downtime is costly, as its dual redundant ports eliminate single points of failure.
- Match Protocol Requirements: Opt for this module if your system uses multiple industrial protocols (e.g., OPC UA for data analytics and DNP3 for utility monitoring) to avoid compatibility issues and extra hardware costs.
- Assess Environmental Conditions: Select the GE IC695ETM001-EJ for harsh industrial settings with extreme temperatures or electrical interference, as its rugged design outperforms competitors with narrower operating ranges.
- Align with GE Ecosystem: Prioritize this module for GE RX3i PLC systems to ensure seamless integration, optimal performance, and full support from GE’s technical services.
Precautions
- Port Configuration: Assign distinct IP addresses to the two Ethernet ports to prevent network conflicts; configure one port for control traffic and the other for monitoring/data logging to optimize network bandwidth.
- Firmware Maintenance: Regularly update the module’s firmware via GE’s official Proficy software to access new protocol features and address security vulnerabilities—never use unapproved third-party firmware.
- Cable and Connection Care: Use industrial-grade Cat6a Ethernet cables for maximum signal integrity, especially in high-interference environments; inspect cable connectors periodically for dust or damage.
- Static Protection: Always use anti-static wristbands when handling the GE IC695ETM001-EJ during installation or maintenance to prevent electrostatic discharge from damaging internal components.
- Power Supply Stability: Connect the module to a regulated 24 VDC power supply with surge protection to avoid voltage fluctuations that may cause communication interruptions or module failure.


IC695ETM001-EJ