Description
Parameters
| Parameter | Specification |
|---|---|
| Input Channels | 10, differential (isolated), with dual redundant ADC paths per channel |
| Input Ranges | ±10V, 0–20mA, 4–20mA (software selectable per channel) |
| Overload Protection | ±30V continuous (voltage); ±50mA (current) |
| ADC Resolution | 16-bit SAR (dual paths) |
| Accuracy | ±0.1% FS at 25°C; ±0.25% over -40°C to +70°C |
| Redundancy Architecture | Dual ADC per channel with cross-checking and voting |
| Input Impedance | >1MΩ (voltage mode); 250Ω (current mode) |
| Filtering | Programmable low-pass: 10Hz, 50Hz, 100Hz, 500Hz |
| Sample Rate | 10Hz–500Hz (software selectable) |
| Redundancy Diagnostics | ADC comparison, channel mismatch detection, auto-failover |
| CMRR | >90dB at 50/60Hz |
| Diagnostics | Over-range, under-range, open-wire detection, reference voltage monitor, ADC self-test |
| Isolation | 1500Vrms (input-to-backplane); 500VDC (channel-to-channel) |
| Power Supply | 5VDC (backplane), 400mA; 24VDC aux, 150mA |
| Operating Temp | -40°C to +70°C |
| Mounting | 6U VME Eurocard, 160mm depth |
| Certifications | UL, CSA, ATEX Zone 2, SIL 2 capable |
Advantages & Features
-
Dual ADC Redundancy – The GE DS4820R10 provides two independent ADC paths per channel. If one ADC fails or deviates, the module automatically uses the redundant path, ensuring continuous measurement availability.
-
Cross-Channel Comparison – The GE DS4820R10 continuously compares the two ADC readings. If a mismatch beyond configurable tolerance occurs, a fault is reported to the Mark VIe controller for operator action.
-
High Channel Density with Redundancy – The GE DS4820R10 provides 10 redundant channels in a single slot, significantly reducing rack space compared to using two separate non-redundant modules.
-
SIL 2 Capable – With dual redundant ADC paths and comprehensive diagnostics, the GE DS4820R10 is suitable for safety-critical applications (SIL 2) with appropriate proof-testing and voting logic.
-
Versatile Input Ranges – Each channel can be independently configured for voltage or current signals, accommodating mixed sensor types without additional modules.
-
Automatic Failover – If the primary ADC fails, the GE DS4820R10 automatically switches to the redundant path with no interruption (<1ms) to the measurement value.
Application Cases
-
Turbine Exhaust Temperature Monitoring – The GE DS4820R10 monitors 10 critical exhaust temperature thermocouple signals (via transmitters) in a gas turbine, with dual ADC paths ensuring no single point of failure can cause a loss of temperature data.
-
Bearing Temperature Protection – In a steam turbine, the GE DS4820R10 monitors 10 bearing RTD signals (via 4–20mA transmitters) with redundant measurement paths, ensuring continuous monitoring for over-temperature protection.
-
Pressure Protection Loops – The GE DS4820R10 monitors 10 critical pressure transmitters (4–20mA) in a compressor anti-surge system, with cross-checking ensuring sensor integrity.
-
Nuclear Feedwater Control – In a nuclear power plant, the GE DS4820R10 monitors 10 feedwater flow and pressure transmitters with redundant ADCs for safety-related control loops.
Competitor Comparison
| Feature | GE DS4820R10 | Siemens 6ES7331-7KF02 (redundant) | ABB AI810 (redundant) | Rockwell 1756-IF16 (redundant) |
|---|---|---|---|---|
| Redundant Channels | 10 (dual ADC) | 4 (dual module) | 4 (dual module) | 4 (dual module) |
| Redundancy Method | On-board dual ADC | External module redundancy | External module redundancy | External module redundancy |
| Cross-Channel Comparison | Yes (built-in) | No (requires logic) | No | No |
| Auto-Failover | Yes (<1ms) | No (manual) | No | No |
| Channel Density | 10 per slot | 4 per slot | 4 per slot | 4 per slot |
| SIL Rating | SIL 2 | SIL 1 | SIL 2 | SIL 1 |
| Relative Cost per Channel | Low-Med | High | High | High |
The GE DS4820R10 offers the most cost-effective redundant analog input solution, with 10 channels and on-board dual ADC redundancy. Competitors require two separate modules for redundancy, doubling rack space and cost.
Selection Suggestions
-
Choose the GE DS4820R10 for safety-critical analog measurements where a single sensor/input failure cannot be tolerated (exhaust temperature, bearing temperature, pressure protection).
-
If your application does not require redundancy, the lower-cost DS4820A1SA or DS4820B1SA may be sufficient.
-
For SIL 2 applications, the GE DS4820R10 can be used with external voting logic (2-out-of-3) and periodic proof-testing (every 24 months).
-
Configure the mismatch tolerance based on expected normal variation. For temperature sensors, 5–10% mismatch may be acceptable; for pressure sensors, 1–2% is typical.
-
Pair with matching terminal block TB500-R10 (with redundant wiring terminals for each channel).
Precautions
-
ADC Mismatch Tolerance – Set the mismatch tolerance appropriately. Too tight a tolerance may cause nuisance alarms; too loose may mask genuine failures. GE recommends starting at 5% and adjusting based on field data.
-
Auto-Failover Behavior – The GE DS4820R10 automatically switches to the redundant ADC on mismatch detection. No operator intervention is required, but a fault is logged for maintenance.
-
Input Selection – Configure each channel for voltage or current mode via software. For current signals, the module automatically connects the 250Ω shunt.
-
Open-Wire Detection – The GE DS4820R10 detects open-wire by injecting a small test current. For 4–20mA loops, this works reliably. For voltage signals, open-wire detection may cause slight loading — disable it for high-impedance sensors.
-
Grounding – Use differential inputs to reject ground loop noise. Connect signal commons to the module negative input if required.
-
Calibration – Factory calibration is valid for 24 months. For ISO 17025 compliance, recalibrate using a precision voltage/current source (0.01% accuracy).
-
Power Supply – The GE DS4820R10 draws 400mA from 5V plus 150mA from 24V aux. Ensure the power supply module has sufficient capacity.
-
Firmware – The GE DS4820R10 requires Mark VIe controller firmware v7.0 or higher for redundancy features.
-
ESD Handling – Use ESD-safe practices when handling the GE DS4820R10. The front-panel connector and ADC inputs are sensitive to electrostatic discharge.
.
A-B 1756-BA2
A-B 1747-L542ϵ и ӣ ͷ
A-B 1756-BA2