GE DS4815COMD

¥999.00

The GE DS4815COMD is a high-density communication and digital I/O module for the GE Mark VIe control system, offering enhanced communication capabilities compared to the DS4815COMC. The suffix -COMD indicates Communication with Combined I/O and Dual Redundant Communication Channels, providing dual-redundant serial ports and enhanced digital I/O functionality. This module offers 8 digital input channels, 8 digital output channels, and 4 serial communication ports (2x RS-232, 2x RS-485) in a single slot. The GE DS4815COMD is optimized for turbine auxiliary control applications requiring both discrete I/O and multiple serial device connections (e.g., gas chromatographs, flow computers, VFDs, and analyzers). Each digital channel is rated for 125VDC or 240VAC operation, while the serial ports support Modbus RTU (master/slave), DNP3, and GE-proprietary protocols. The module features hardware-level isolation between the communication and I/O sections, ensuring reliable operation in electrically noisy environments.

Category:

Description

Parameters

Parameter Specification
Digital Input Channels 8, optically isolated
Digital Output Channels 8, solid-state (MOSFET/thyristor)
Digital Input Voltage 0–250VAC/VDC (threshold: 24V min for ON)
Digital Output Voltage 24–250VAC/VDC (sourcing or sinking, configurable per channel)
Output Current per Channel 2A continuous; 5A surge (1s)
Total Output Current 8A (max)
Serial Ports 4: 2x RS-232 (DB9), 2x RS-485 (DB9, software selectable)
Serial Baud Rate 300–115200 bps
Serial Protocols Modbus RTU (master/slave), DNP3 (outstation), GE proprietary (Mark VIe data link), ASCII
Input Debounce Programmable: 0.1ms–100ms
Input Wetting Current 5–20mA (programmable per channel)
Diagnostics Open-wire detection, short-circuit detection, over-temperature, communication errors, input state readback, port status monitoring
Protection Short-circuit protection (current limit), thermal shutdown (95°C), transient suppression (MOV + TVS)
Update Rate 1ms (digital I/O); 10ms (serial data, typical)
Isolation 2500Vrms (digital I/O to backplane); 1500Vrms (serial ports to backplane); 500VDC (serial to I/O)
Power Supply 5VDC (backplane), 500mA; 24VDC aux (I/O and wetting), 450mA + output load
Operating Temp -40°C to +70°C
Mounting 6U VME Eurocard, 160mm depth
Certifications UL, CSA, ATEX Zone 2, SIL 1 capable

Advantages & Features

  • High Communication Density – The GE DS4815COMD provides 4 independent serial ports (2x RS-232, 2x RS-485) in a single module, enabling connections to multiple field devices without additional communication modules.

  • Combined I/O + Multi-Port Communication – The GE DS4815COMD replaces a digital I/O module and multiple serial communication modules, saving rack space and reducing system cost.

  • High-Voltage Digital I/O – The GE DS4815COMD directly interfaces with 125VDC and 240VAC field circuits, eliminating external relays for most applications.

  • Configurable Serial Protocols – The GE DS4815COMD supports Modbus RTU, DNP3, ASCII, and GE proprietary protocols, providing flexibility for connecting to gas chromatographs, flow computers, VFDs, and analyzers.

  • Isolation Between I/O and Communication – The GE DS4815COMD provides 500VDC isolation between the serial ports and digital I/O sections, preventing ground loops and noise coupling.

  • Redundant Communication Paths – Multiple serial ports allow the GE DS4815COMD to provide redundant communication paths for critical field devices.


Application Cases

  • Turbine Auxiliary System Interface – The GE DS4815COMD communicates with a gas chromatograph (RS-485), two flow computers (RS-232), and a VFD (RS-485), while simultaneously monitoring valve position switches and controlling solenoid valves.

  • Compressor Station Control – In a gas compressor station, the GE DS4815COMD reads pressure switch status (8 inputs), controls anti-surge valves (8 outputs), and communicates with four VFDs via Modbus RTU for speed control.

  • Generator Hydrogen Monitoring – The GE DS4815COMD monitors hydrogen purity analyzer alarms, controls purge valves, and communicates with multiple gas analyzers via independent serial ports.

  • Water Treatment Plant – The GE DS4815COMD monitors pump status, controls chemical dosing valves, and communicates with two flow computers and a pH analyzer via RS-485 multi-drop networks.


Competitor Comparison

Feature GE DS4815COMD GE DS4815COMC Siemens 6ES7151 + CP ABB CI801 + DI/DO Rockwell 1734-AENT + serial
Combined I/O + Serial Yes Yes No No No
Digital Inputs 8 8 8 (separate) 8 (separate) 8 (separate)
Digital Outputs 8 8 8 (separate) 8 (separate) 8 (separate)
Serial Ports 4 (2x RS-232, 2x RS-485) 2 (RS-232/RS-485) 1 (via CP) 1 (via CI) 1 (via adapter)
Protocols Modbus, DNP3, ASCII, GE Modbus, DNP3, GE Modbus, Profibus Modbus, Profibus Modbus, EtherNet/IP
I/O Voltage Range 24–250VAC/VDC 24–250VAC/VDC 24–240VAC/VDC 24–250VDC 24–240VAC/VDC
SIL Rating SIL 1 SIL 1 SIL 1 SIL 2 SIL 1
Slot Count 1 1 3–4 3 3–4

The GE DS4815COMD offers the highest communication port density (4 serial ports) combined with 8 inputs and 8 outputs in a single slot — a feature not matched by the DS4815COMC or any competitor.


Selection Suggestions

  • Select the GE DS4815COMD when your application requires 8 digital I/O points and multiple serial device connections (up to 4 devices) within a single Mark VIe rack slot. It is ideal for turbine auxiliaries with multiple field instruments.

  • If your application requires only one or two serial ports, the lower-cost DS4815COMC may be sufficient.

  • Assign each serial port to a specific field device based on distance: RS-232 for short distances (<15m), RS-485 for longer distances (up to 1200m) or multi-drop networks.

  • For SIL 2 safety applications, the GE DS4815COMD is not rated SIL 2 — use separate safety-rated modules.

  • Verify the communication protocol and settings of each field device. The GE DS4815COMD supports Modbus RTU (most common), DNP3 (utility), and ASCII.

  • Pair with matching terminal block TB500-HV for digital I/O connections and standard DB9 cables for serial ports.


Precautions

  • Serial Port Allocation – Each port can be configured independently as RS-232 or RS-485 (for the two RS-485 ports) or fixed RS-232 for the dedicated RS-232 ports. Plan your wiring accordingly.

  • RS-485 Multi-Drop Networks – Use twisted-pair shielded cable with 120Ω termination resistors at both ends of the bus. The GE DS4815COMD includes selectable termination per RS-485 port via software.

  • RS-232 Cabling – Cable length must not exceed 15m. Use proper handshaking lines (RTS/CTS) if required by the field device.

  • Port Isolation – The serial ports share a common ground with each other. For fully isolated multi-drop networks with different ground potentials, use external isolators.

  • Output Grouping – All outputs on the GE DS4815COMD share a common return. All outputs must be powered from the same voltage source.

  • Output Current Limit – Total output current is limited to 8A (combined across all 8 channels). Ensure the total load does not exceed this limit.

  • Wetting Current – For dry contact inputs, enable wetting current (5–20mA) to ensure reliable switching.

  • Mixed Protocol Configuration – All four serial ports can run different protocols simultaneously (e.g., Port 1 = Modbus, Port 2 = DNP3, Port 3 = ASCII, Port 4 = GE proprietary).

  • Power Supply – The GE DS4815COMD draws 500mA from 5V plus output load current. Ensure the power supply module has sufficient capacity.

  • Firmware – The GE DS4815COMD requires Mark VIe controller firmware v7.5 or higher for full serial protocol support.

  • ESD Handling – Use ESD-safe practices when handling the GE DS4815COMD. Serial ports and output stages are sensitive to electrostatic discharge.

MVI56-MCMˮ ͷ
Prosoft 1454-9F
A-B 1747-BA
PR0S0FT 1454-9F

Reviews

There are no reviews yet.

Be the first to review “GE DS4815COMD”

Your email address will not be published. Required fields are marked *

Post comment