Description
Parameters
| Parameter | Specification |
|---|---|
| Channels | 8, independent counter/timer/pulse generator |
| Input Frequency | Up to 10MHz (measurement); up to 5MHz (output generation) |
| Counter Resolution | 32-bit (up to 4.29 billion counts) |
| Frequency Accuracy | ±0.001% of reading (with precision timebase) |
| Input Types | Voltage pulse, magnetic pickup, proximity probe, encoder (A/B/Z), TTL/CMOS |
| Input Range | ±5V, ±10V, 0–24V, 5–24V (software selectable per channel) |
| Output Type | Programmable pulse (TTL/CMOS, 0–5V), PWM (50Hz–5MHz) |
| Output Drive | 10mA (max) |
| Quadrature Decoding | 1x, 2x, 4x (software selectable) |
| Capture/Compare | 2 capture registers + 2 compare registers per channel |
| Time-stamp Resolution | 1µs |
| Diagnostics | Input open/short detection, over-frequency, missing pulse detection |
| Isolation | 1500Vrms channel-to-backplane; 500VDC channel-to-channel |
| Power Supply | 5VDC (backplane), 450mA; 24VDC aux, 100mA |
| Operating Temp | -40°C to +70°C |
| Mounting | 6U VME Eurocard, 160mm depth |
| Certifications | UL, CSA, ATEX Zone 2, SIL 1 capable |
Advantages & Features
-
Dual Counter/Generator Function – The GE DS3860HSCG can independently count pulses on one channel while generating output pulses on another, enabling closed-loop actuator control with minimal controller overhead.
-
High-Speed Measurement – With 10MHz input capability, the GE DS3860HSCG can measure high-speed turbine speed signals (up to 600,000 RPM with a 1-pulse-per-revolution sensor).
-
Programmable Pulse Output – The GE DS3860HSCG generates precise pulse trains (frequency and duty cycle programmable) for stepping motor control, valve dither, or testing applications.
-
Quadrature Decoding – Supports incremental encoders with 1x, 2x, or 4x decoding for high-resolution position feedback.
-
Capture/Compare Registers – The GE DS3860HSCG includes capture registers for time-stamped event logging and compare registers for generating interrupts or output events at specific counter values.
-
Integrated Diagnostics – Continuous monitoring detects input open-circuit, over-frequency, and missing pulses, with faults reported to the Mark VIe controller.
Application Cases
-
Turbine Speed Measurement – The GE DS3860HSCG measures speed signals from two independent magnetic pickups on a steam turbine, providing redundant speed inputs for governor control and overspeed protection.
-
Flow Meter Pulse Counting – In a chemical plant, the GE DS3860HSCG counts pulses from 8 turbine flow meters (0–10kHz), providing totalized flow and instantaneous flow rate data to the Mark VIe controller.
-
PWM Valve Control – The GE DS3860HSCG generates PWM signals (1kHz, variable duty cycle) to control proportional solenoid valves in a hydraulic control system, eliminating the need for separate PWM driver modules.
-
Encoder Position Feedback – The GE DS3860HSCG reads quadrature encoder signals from a robotic actuator, providing high-resolution position feedback for precise motion control.
Competitor Comparison
| Feature | GE DS3860HSCG | Siemens 6ES7350-2AH00 | ABB CI541 | Rockwell 1756-HSC |
|---|---|---|---|---|
| Channels | 8 | 2 | 4 | 2 |
| Max Input Frequency | 10MHz | 500kHz | 500kHz | 1MHz |
| Max Output Frequency | 5MHz | No output | No output | No output |
| Counter Resolution | 32-bit | 32-bit | 16-bit | 32-bit |
| Pulse Output | Yes (programmable) | No | No | No |
| Quadrature Decoding | Yes (1x,2x,4x) | Yes (1x,2x) | Yes (1x,2x) | Yes (1x,2x,4x) |
| Capture/Compare Registers | Yes (2+2 per channel) | No | No | Yes (limited) |
| Time-stamp Resolution | 1µs | 10µs | 10µs | 1µs |
| SIL Rating | SIL 1 | SIL 1 | SIL 2 | SIL 1 |
The GE DS3860HSCG offers the highest channel count (8), highest input frequency (10MHz), and unique pulse output capability — features not matched by Siemens, ABB, or Rockwell.
Selection Suggestions
-
Choose the GE DS3860HSCG when you need high-speed counting (up to 10MHz) on multiple channels, or when you require programmable pulse output in the same module.
-
If your application requires only frequency measurement (no pulse output), the lower-cost DS3860HSC variant (without -G) may be sufficient.
-
For encoder feedback applications, use the GE DS3860HSCG with 4x quadrature decoding for maximum resolution.
-
For PWM valve control, select the GE DS3860HSCG output frequency that matches the valve’s response characteristics (typically 50Hz–5kHz). Avoid frequencies that may cause valve resonance.
-
Pair with matching terminal block TB300-HSC (with shielded connections for high-frequency inputs).
Precautions
-
Input Threshold Setting – The GE DS3860HSCG uses programmable voltage thresholds. Set the threshold to 50% of the expected signal amplitude. Too high a threshold may miss pulses; too low may trigger on noise.
-
Cable Quality – For high-frequency signals (>1MHz), use low-capacitance shielded coaxial or twisted-pair cable (<50pF/m) and keep cable runs as short as possible (<15m). Signal attenuation can cause missed counts.
-
Grounding – Connect cable shields to the GE DS3860HSCG common terminal at the module end only. Do not ground shields at both ends to avoid ground loops.
-
Output Loading – The GE DS3860HSCG output is limited to 10mA. For higher drive current, use an external buffer amplifier.
-
PWM Output Filtering – For analog control applications, the PWM output may require external low-pass filtering (RC or active filter) to convert the digital PWM signal to a smooth analog voltage.
-
Counter Rollover – The 32-bit counter rolls over after 4.29 billion counts. For applications counting at 10MHz, this occurs every 429 seconds (~7 minutes). Implement rollover handling in the controller logic.
-
Missing Pulse Detection – The missing pulse diagnostic triggers if no pulse is detected within the expected time window. For variable-speed applications, set a wide enough window (e.g., 200ms) to avoid false alarms during startup.
-
Power Supply – The GE DS3860HSCG draws 450mA from 5V. Verify the power supply module has sufficient 5V capacity.
-
Calibration – The internal timebase is factory-calibrated. Field recalibration is not required.
-
ESD Handling – Use ESD-safe practices when handling the GE DS3860HSCG. High-frequency inputs are particularly sensitive to static discharge.

A-B 1747-BA
A-B 1746-NI8ϵ и
A-B 1747-BA


Reviews