GE DS38600HCVA

¥999.00

The GE DS38600HCVA is a high-capacity voltage analog input module for the GE Mark VIe control system, designed for precision measurement of high-voltage signals in power generation and heavy industrial applications. The suffix -HCVA indicates High-Capacity Voltage Analog input with extended input range and enhanced isolation. This module provides 8 differential analog input channels, each configurable for ±10V, ±20V, ±50V, or ±100V DC voltage ranges, making the GE DS38600HCVA suitable for monitoring generator field voltage, battery bank voltages, and high-level transducer signals. The module features 24-bit Sigma-Delta ADC, programmable input filtering, and comprehensive diagnostics including over-range, under-range, and open-wire detection. The GE DS38600HCVA communicates via the Mark VIe high-speed backplane with configurable scan rates from 10ms to 1s.

Category:

Description

Parameters

Parameter Specification
Input Channels 8, differential (isolated per channel)
Input Ranges ±10V, ±20V, ±50V, ±100V DC (software selectable per channel)
Overload Protection ±250V continuous; ±500V transient (1ms)
ADC Resolution 24-bit Sigma-Delta
Accuracy ±0.05% of reading + ±0.01% of range at 25°C; ±0.15% over -40°C to +70°C
Input Impedance >10MΩ (all ranges)
Common-Mode Voltage ±200V (DC or AC peak)
CMRR >100dB at 50/60Hz
Filtering Programmable low-pass: 10Hz, 50Hz, 100Hz, 500Hz, 1kHz
Sample Rate 10Hz–200Hz (software selectable)
Diagnostics Over-range, under-range, open-wire detection, reference voltage monitor
Isolation 2500Vrms channel-to-backplane; 500VDC channel-to-channel
Power Supply 5VDC (backplane), 300mA; 24VDC aux, 100mA
Operating Temp -40°C to +70°C
Mounting 6U VME Eurocard, 160mm depth
Certifications UL, CSA, ATEX Zone 2, SIL 2 capable

Advantages & Features

  • Wide Input Range – The GE DS38600HCVA handles signals from millivolts up to ±100V, eliminating the need for external voltage dividers for most high-voltage measurements. This simplifies wiring and reduces failure points.

  • High Accuracy – 24-bit resolution and ±0.05% accuracy make the GE DS38600HCVA suitable for precise generator field voltage monitoring, where small variations affect reactive power control.

  • Enhanced Isolation – 2500Vrms channel-to-backplane and 500V channel-to-channel isolation protect the Mark VIe controller from high-voltage transients and ground loops common in power plants.

  • High Common-Mode Rejection – >100dB CMRR ensures the GE DS38600HCVA rejects noise from nearby AC power cables, providing stable readings in electrically noisy environments.

  • Flexible Filtering – Programmable filters allow the GE DS38600HCVA to be configured for fast response (500Hz) or noise rejection (10Hz) depending on the application.

  • Diagnostic Coverage – Continuous monitoring of input integrity, reference voltage, and ADC health ensures the GE DS38600HCVA provides reliable data. Faults are reported to the controller within one scan cycle.


Application Cases

  • Generator Field Voltage Monitoring – The GE DS38600HCVA measures the DC field voltage of a 300MW generator (0–500V scaled via external divider to ±50V), providing critical input for the excitation control system and over-excitation protection.

  • Battery Bank Voltage Monitoring – In a UPS system, the GE DS38600HCVA monitors four independent 125VDC battery strings (scaled to ±100V range), detecting failing cells and triggering alarms before critical loads are affected.

  • High-Level Transducer Signals – In a gas turbine, the GE DS38600HCVA reads ±10V signals from pressure transducers, flow meters, and position sensors, consolidating all high-level analog signals into a single 8-channel module.

  • DC Bus Voltage Monitoring – The GE DS38600HCVA monitors the 600VDC bus in a variable-frequency drive system (via external voltage divider), ensuring the drive operates within safe voltage limits during regenerative braking.


Competitor Comparison

Feature GE DS38600HCVA Siemens 6ES7331-7HF01 ABB AI810 (high-voltage) Rockwell 1756-IF8 (high-voltage)
Channels 8 8 8 8
Input Ranges ±10V, ±20V, ±50V, ±100V ±10V only ±10V, ±30V, ±60V ±10V only
Overload Protection ±250V continuous ±30V continuous ±100V continuous ±30V continuous
Accuracy ±0.05% ±0.1% ±0.1% ±0.15%
Isolation 2500V (channel-to-backplane) 500V 2500V 500V
CMRR >100dB >90dB >95dB >90dB
Programmable Filter Yes Yes Yes No
SIL Rating SIL 2 SIL 1 SIL 2 SIL 1
Relative Cost High Low-Med High Med

The GE DS38600HCVA offers the widest input range (±100V) and highest overload protection (±250V) among competitors. ABB provides similar isolation but lacks the ±100V range. Siemens and Rockwell are limited to ±10V, requiring external dividers for high-voltage measurements.


Selection Suggestions

  • Choose the GE DS38600HCVA when you need to measure high-voltage DC signals (up to ±100V) with high accuracy, or when you require enhanced isolation for safety-critical applications.

  • For signals >100V, use an external voltage divider or transducer to scale the signal to within the GE DS38600HCVA input range. The module does not support direct connection to >100V without external attenuation.

  • If your application requires only ±10V signals and standard isolation, the lower-cost DS38600VA (without -HC suffix) may be sufficient.

  • For SIL 2 safety loops, the GE DS38600HCVA can be used with external voting logic and periodic proof-testing.

  • Pair with matching terminal block TB300-HV (high-voltage rated with safe isolation barriers) for field wiring.


Precautions

  • Voltage Dividers – For signals >100V, use precision voltage dividers (0.1% tolerance) to scale to the GE DS38600HCVA input range. Ensure the divider has adequate power rating and safety isolation. The GE DS38600HCVA does not provide internal attenuation.

  • Wiring and Safety – High-voltage wiring must comply with local safety standards (e.g., NEC, IEC). Use insulated cables rated for the maximum input voltage and maintain proper creepage distances to the module connector.

  • Common-Mode Voltage – The GE DS38600HCVA can tolerate ±200V common-mode. Exceeding this will damage the input stage. If your signal source has high common-mode voltage (e.g., floating battery strings), use isolated transducers or add external isolation amplifiers.

  • Input Filter Selection – For high-frequency noise (e.g., from VFDs), select the 10Hz or 50Hz filter on the GE DS38600HCVA. For transient response (e.g., excitation step tests), use 500Hz or 1kHz. The filter is applied per channel.

  • Overload Recovery – If the GE DS38600HCVA experiences an overload (>±250V), the input may take up to 1 second to recover after the overload is removed. Design protection circuits (e.g., transient voltage suppressors) to prevent prolonged overload conditions.

  • Calibration Interval – Factory calibration valid for 24 months. For ISO 17025 compliance, recalibrate using a precision DC voltage source (0.01% accuracy) following GE service procedure GET-67890.

  • Input Capacitance – The GE DS38600HCVA has input capacitance of approximately 100pF. For high-impedance sources (>10kΩ), this may cause settling errors — increase the settling delay via software configuration.

  • Ground Loops – Use the differential inputs to reject ground loop noise. Connect the signal source’s common to the GE DS38600HCVA‘s negative input terminal only if required; otherwise, let the differential input float.

  • ESD Protection – The front-panel connector is ESD-sensitive. Use ESD-safe practices when handling the GE DS38600HCVA outside the rack

A-B MVI56-MCM
A-B 1746-A10
A-B 1747-CP3

Reviews

There are no reviews yet.

Be the first to review “GE DS38600HCVA”

Your email address will not be published. Required fields are marked *

Post comment