Description
Key Parameters
-
Channels: 8 isolated analog inputs
-
Input Types: 4–20 mA, 0–10 V, ±10 V (software-configurable per channel)
-
Resolution: 16-bit ADC
-
Accuracy: ±0.1% of full scale (25°C); ±0.3% over –40°C to +70°C
-
Input Impedance: >1 MΩ (voltage), 250 Ω (current)
-
Sampling Rate: Up to 500 Hz per channel (high-speed mode; filtering disabled)
-
EMC/Noise Rejection: CMRR > 100 dB, built-in 50/60 Hz digital filtering
-
Diagnostics: Open-circuit detection, short-circuit detection, over-range/under-range, signal-loss detection, per-channel LED status
-
Isolation: 1500 V RMS (field-to-backplane); 500 V RMS between channels (per-channel isolation)
-
Operating Temperature: –40°C to +70°C
-
Terminal Type: Screw-type – per suffix “D06AA”
-
Power: 24 V DC backplane power, ≤5 W
-
Dimensions: Standard double-width Eurocard form factor
Advantages
-
High channel density – 8 isolated channels in a single module; saves rack space.
-
Software-configurable per channel – each channel independently set for current or voltage; eliminates hardware jumpers.
-
Per-channel isolation – 500 V between channels; prevents ground loops, cross-channel interference, and channel-to-channel faults.
-
High-speed 500 Hz sampling – captures fast-changing process signals for dynamic control applications.
-
16-bit resolution – provides precise measurement fidelity.
-
Open/short detection – detects broken wires or sensor shorts instantly.
-
Enhanced diagnostics – includes signal-loss detection for proactive maintenance.
-
Hot-swappable – replace without rack power-down.
-
Wide measurement range – supports standard industrial signal types.
-
Optical isolation – protects backplane from field transients.
Applications
-
Oil & gas pipelines – pressure, flow, and temperature monitoring with long cable runs
-
Chemical processing – reactor and tank level/pressure monitoring
-
Power generation – turbine and generator monitoring with high-speed sampling
-
Water/wastewater – pump station and treatment plant monitoring
-
Pharmaceutical manufacturing – critical process variable monitoring
-
Food processing – temperature, pressure, and flow monitoring
-
HVAC – building-wide analog signal monitoring
-
Mining – equipment and process monitoring
Competitor Comparison
| Feature | DS3826AS1D06AA | Standard Analog Input Module (8-ch, 12-bit) | Competitor 8-ch Isolated AI Module |
|---|---|---|---|
| Channels | 8 | 8 | 8 |
| Resolution | 16-bit | 12-bit | 16-bit |
| Sampling Rate | 500 Hz | 100 Hz | 500 Hz |
| Per-channel Isolation | Yes (500 V) | No (group only) | Yes (500 V) |
| Configuration | Software per-channel | Hardware (jumpers) | Software per-channel |
| Diagnostics | Enhanced (signal-loss) | Basic | Basic |
| Cost per channel | Low | Very low | High |
The DS3826AS1D06AA is the high-density, per-channel isolated analog input module – offering 8 channels with 16-bit resolution, 500 Hz sampling, and full per-channel isolation. Compared to standard 8-channel modules, it provides superior isolation, higher resolution, and faster sampling – essential for critical process control applications. For demanding analog input applications requiring high channel density, isolation, and speed, the DS3826AS1D06AA delivers the best-in-class solution.
Selection Tips
-
Choose DS3826AS1D06AA when you need high-density analog inputs (8 channels) with per-channel isolation, high-speed sampling (500 Hz), and software-configurable input types.
-
Ideal for oil & gas, chemical processing, power generation, and water/wastewater applications.
-
Verify the input type for each channel – software-configurable for 4–20 mA, 0–10 V, or ±10 V.
-
Confirm the terminal configuration (D06AA) matches your panel wiring requirements.
-
For maximum speed (500 Hz), disable input filtering – enabling 50/60 Hz rejection reduces sampling rate.
-
Ensure your PLC/DCS can handle the data throughput from DS3826AS1D06AA at 500 Hz.
-
Not suitable for thermocouple or RTD sensors – use dedicated modules for those sensor types.
Precautions
-
Sampling rate vs. filtering: Maximum 500 Hz achieved with filtering disabled. Enable filtering only if noise rejection is required – it will reduce the sampling rate.
-
Isolated grounds: Do not tie the isolated commons of different channels together – this defeats the isolation and can create ground loops. The DS3826AS1D06AA maintains 500 V isolation between channels only when commons are kept separate.
-
Wiring: Use shielded twisted-pair cables for analog inputs, especially at high sampling rates. Ground shield at module end only.
-
Input overload: Do not exceed the input range (max ±30 V or 50 mA) – exceeding may damage the input circuitry.
-
Data throughput: 500 Hz × 8 channels × 16-bit data requires significant communication bandwidth – ensure your PLC/DCS can process the data rate.
-
Power sequencing: Apply backplane power before field power.
-
Calibration: Perform periodic calibration using precision sources to maintain accuracy – high-speed operation may accelerate drift.
-
Spare: Keep one spare DS3826AS1D06AA for critical high-channel-count loops – the high-density, isolated variant may have longer lead times.