Description
Key Parameters
-
Type: Dual-redundant DC power supply module
-
Input Voltage: 18–72 V DC (wide range) – compatible with 24 V, 48 V, and 60 V DC systems
-
Input Current: 6 A maximum per input (at 24 V DC input)
-
Output Voltage: 24 V DC (regulated) – 22.8–25.2 V DC
-
Output Current: 10 A total (5 A per redundant rail)
-
Redundancy Mode: Active/Active with automatic fail-over (switchover time < 1 ms)
-
Efficiency: >88% (typical)
-
Protection: Overcurrent protection, overvoltage protection, short-circuit protection, thermal protection, reverse-polarity protection (input)
-
Diagnostics: Input status per channel, output status per rail, overload/fault indication, over-temperature alert, per-LED status
-
Isolation: 1500 V RMS (input-to-output); 500 V RMS between input channels
-
Terminal Type: Screw-type – per suffix “A”
-
Cooling: Convection (derating above 50°C)
-
Operating Temperature: –40°C to +70°C (derate output above 50°C)
-
Power Consumption: ≤2 W (no load)
-
Dimensions: Standard single-width Eurocard form factor (approx. 100 mm × 160 mm)
Advantages
-
Dual-redundant power inputs – two independent power sources with automatic fail-over; ensures uninterrupted system power in case of primary supply failure.
-
Ultra-fast fail-over (< 1 ms) – zero interruption to sensitive PLC/DCS operations.
-
Wide input voltage range (18–72 V DC) – compatible with 24 V, 48 V, and 60 V DC systems; eliminates the need for separate power converters.
-
High output capacity (10 A total) – sufficient for most mid-size backplane and field device power requirements.
-
Hot-swappable – replace without powering down the rack; critical for high-availability systems.
-
Comprehensive protection – overcurrent, overvoltage, short-circuit, thermal, and reverse-polarity protection ensure module and load safety.
-
Diagnostic monitoring – real-time status of input channels, output rails, and fault conditions via backplane communication.
-
High efficiency (>88%) – minimizes heat dissipation and reduces cooling requirements.
-
Wide temperature range – –40°C to +70°C for harsh industrial environments.
-
Optical isolation – protects backplane from input transients.
Applications
-
Critical process control – petrochemical, refining, and chemical plants requiring uninterrupted control power
-
Power generation – turbine and generator control systems with redundant power requirements
-
Oil & gas pipelines – SCADA and control system power for remote, critical infrastructure
-
Nuclear power plants – safety-critical systems requiring power redundancy
-
Pharmaceutical manufacturing – continuous process control with high-availability requirements
-
Data centers – control system power with dual-grid or generator-backed sources
-
Transportation – rail and airport control systems requiring redundant power
-
Water/wastewater – critical pumping station control with redundant power sources
Competitor Comparison
| Feature | DS3820RPSA | Standard Single Power Supply Module | Competitor Redundant Power Module |
|---|---|---|---|
| Redundancy | Dual-input, automatic fail-over | None | Dual-input, automatic fail-over |
| Fail-over Time | < 1 ms | N/A | < 5 ms |
| Input Voltage Range | 18–72 V DC | 24 V DC only | 18–36 V DC |
| Output Current | 10 A total | 5 A | 10 A |
| Hot-swappable | Yes | No | Yes |
| Diagnostics | Full (input/output/fault) | Basic | Basic |
| Protection | Overcurrent, overvoltage, short-circuit, thermal, reverse-polarity | Overcurrent only | Overcurrent, overvoltage |
| Efficiency | >88% | >85% | >86% |
| Cost | Mid | Low | High |
The DS3820RPSA is the redundant power supply module – offering dual-input power with automatic fail-over and wide input range in a single slot. Compared to standard single power supplies, it provides critical redundancy and full diagnostic feedback – essential for high-availability systems. Against competitor redundant power modules, it offers faster fail-over (< 1 ms vs. < 5 ms), wider input range (18–72 V vs. 18–36 V), and superior protection features at a lower cost. For mission-critical systems requiring uninterrupted power, the DS3820RPSA delivers the most reliable and cost-effective solution.
Selection Tips
-
Choose DS3820RPSA when your system requires redundant DC power with automatic fail-over for high-availability operation.
-
Ideal for critical process control, power generation, oil & gas, nuclear, and pharmaceutical applications.
-
Verify input voltage sources – supports 24 V, 48 V, or 60 V DC systems (18–72 V range).
-
Calculate total power consumption – provides 10 A total at 24 V DC; ensure loads do not exceed this limit.
-
Consider output derating above 50°C ambient – reduce load by 2.5% per °C above 50°C.
-
Ensure your rack has adequate cooling – the DS3820RPSA dissipates up to 35 W at full load.
-
Not suitable for AC input – use dedicated AC power supply modules for AC sources.
-
Ensure your PLC/DCS can read diagnostic data from the DS3820RPSA.
Precautions
-
Input wiring: Connect two independent power sources (e.g., different UPS or battery banks) to achieve true redundancy. The DS3820RPSA will automatically fail-over if one source fails.
-
Input range: Do not exceed 72 V DC input – higher voltage may damage the module.
-
Output derating: At ambient temperatures >50°C, reduce output load to avoid thermal shutdown.
-
Cooling: Provide adequate airflow in dense racks – the DS3820RPSA dissipates up to 35 W at full load; forced cooling may be required in high-density configurations.
-
Hot-swap operation: The DS3820RPSA is hot-swappable – insert or remove while the rack is powered; verify the other redundant supply is active before removal.
-
Output protection: Outputs include overcurrent protection – repeated overloads may trip protection; ensure loads are within rated capacity.
-
Diagnostic wiring: Diagnostic signals require backplane communication – ensure the module is properly seated in the rack for fault reporting.
-
Grounding: Maintain proper grounding – the DS3820RPSA uses the backplane ground; ensure rack grounding meets specifications.
-
Spare: Keep one spare DS3820RPSA for critical power systems – the redundant feature set may have longer lead times.