Description
Key Parameters
-
Channels: 4 isolated analog inputs
-
Sensor Type: Pt100 (2‑wire, 3‑wire, or 4‑wire – software‑configurable per channel)
-
Resolution: 24‑bit ADC
-
Accuracy: ±0.05°C (Pt100, 25°C); ±0.2°C over –40°C to +70°C
-
Excitation Current: Software‑selectable 0.1 mA, 0.5 mA, 1 mA (per channel)
-
Excitation Power: Line‑powered (AC/DC wide‑range input, 85–265 V AC or 110–300 V DC) – eliminates need for separate 24 V DC field supply for sensors
-
Lead Resistance Compensation: Automatic for 3‑wire and 4‑wire configurations
-
Measurement Range: –200°C to +850°C
-
Sampling Rate: Up to 50 Hz per channel (with 50/60 Hz noise rejection)
-
Diagnostics: Open‑circuit detection, short‑circuit detection, over‑range/under‑range, signal‑loss detection, per‑channel LED status
-
Isolation: 1500 V RMS (field‑to‑backplane); 500 V RMS between channels (per‑channel isolation)
-
Terminal Type: Screw‑type – per suffix “A”
-
Power: 85–265 V AC / 110–300 V DC (internal power supply) – consumes ≤6 W
-
Operating Temperature: –40°C to +70°C
Advantages
-
Pre‑configured – fixed terminal configuration; reduces setup time and engineering effort.
-
Line‑powered excitation – directly powered from AC/DC mains; eliminates the need for a dedicated 24 V DC field supply for sensors, simplifying wiring and reducing panel cost.
-
Long‑distance capability – line‑powered excitation provides stable drive current unaffected by cable voltage drop; ideal for sensors located far from the control panel.
-
Premium accuracy – ±0.05°C; high precision for demanding applications.
-
24‑bit resolution – provides superior measurement fidelity.
-
Per‑channel isolation – 500 V between channels; prevents ground loops and cross‑channel interference.
-
Automatic lead compensation – for 3‑wire/4‑wire RTDs, cancels lead resistance errors for accurate temperature readings.
-
Software‑configurable per channel – wire configuration and excitation current independently settable.
-
Built‑in linearization – provides direct temperature readout in °C or °F; no scaling required.
-
Enhanced diagnostics – includes signal‑loss detection for proactive maintenance.
-
Open/short detection – detects broken wires or sensor shorts instantly.
-
Hot‑swappable – replace without rack power‑down.
-
Wide measurement range – –200°C to +850°C covers most industrial applications.
Applications
-
Remote temperature monitoring – pipelines, tanks, and outdoor installations where sensors are located far from the control panel
-
Oil & gas – wellhead and pipeline temperature monitoring with long cable runs
-
Water/wastewater – remote pump station and lift station temperature monitoring
-
HVAC – building‑wide temperature monitoring with distributed sensors
-
Power generation – substation and transformer temperature monitoring
-
Mining – remote equipment temperature monitoring
-
Marine & offshore – engine room and deck temperature monitoring with long cable runs
-
Chemical processing – tank and vessel temperature monitoring in large plants
Competitor Comparison
| Feature | DS3820PSLA1A | DS3820PSLA (Configurable Line‑Powered) | Standard Pt100 Module (16‑bit, 10 Hz, 24 V) |
|---|---|---|---|
| Channels | 4 | 4 | 4 |
| Resolution | 24‑bit | 24‑bit | 16‑bit |
| Accuracy | ±0.05°C | ±0.05°C | ±0.1°C |
| Max Sampling Rate | 50 Hz | 50 Hz | 10 Hz |
| Excitation Power | Line‑powered (AC/DC) | Line‑powered | 24 V DC only |
| Cable Length Capability | Excellent (line‑powered) | Excellent | Limited |
| Configuration | Fixed (suffix) | Software‑configurable | Software‑configurable |
| Setup Time | Instant | Moderate | Moderate |
| Cost | High | High | Low |
The DS3820PSLA1A is the fixed‑configuration, line‑powered Pt100 input module for long‑distance applications. Compared to the configurable DS3820PSLA, it offers plug‑and‑play simplicity while maintaining the same line‑powered excitation, ±0.05°C accuracy, and 50 Hz sampling. Against standard 24 V‑powered Pt100 modules, it eliminates the need for a separate field supply and maintains stable excitation over long cable runs – critical for remote sensor installations. For temperature monitoring in large facilities with distributed sensors, the DS3820PSLA1A delivers the most reliable, cost‑effective, and deployment‑ready solution.
Selection Tips
-
Choose DS3820PSLA1A when your Pt100 sensors are located far from the control panel (long cable runs) or when a separate 24 V DC field supply is unavailable, with plug‑and‑play simplicity.
-
Ideal for pipeline monitoring, remote tanks, outdoor installations, and large‑scale building automation.
-
Verify the wire configuration (2‑wire, 3‑wire, or 4‑wire) – software‑configurable per channel.
-
Confirm the terminal configuration (1A) matches your panel wiring requirements.
-
For 2‑wire sensors, lead resistance adds error – use 3‑wire or 4‑wire for accurate measurements.
-
Not suitable for Pt1000, Ni RTDs, or thermocouples – use dedicated modules.
-
Ensure your PLC/DCS can handle the data format from DS3820PSLA1A.
Precautions
-
Line power connection: The DS3820PSLA1A requires 85–265 V AC or 110–300 V DC mains power – ensure proper fuse and overcurrent protection on the supply line.
-
Power consumption: The module consumes up to 6 W; ensure adequate cooling in dense racks.
-
Lead resistance: For 2‑wire sensors, lead resistance directly adds error – use 3‑wire or 4‑wire for accurate measurements. The DS3820PSLA1A compensates for 3‑wire/4‑wire automatically.
-
Excitation current: Higher currents (1 mA) produce self‑heating errors in small Pt100 elements – use 0.1 mA or 0.5 mA for sensitive sensors.
-
Wiring: Use shielded twisted‑pair cables; ground shield at module end only. For 4‑wire, use separate pairs for excitation and sense leads.
-
Signal‑loss detection: Requires minimum sensor impedance – very low‑impedance sensors may not trigger detection.
-
Power sequencing: Apply mains power before backplane power to avoid power‑up transients.
-
Calibration: Perform periodic calibration using precision resistors to maintain accuracy.
-
Spare: Keep one spare DS3820PSLA1A for critical remote temperature loops – the fixed configuration is typically stocked for quick replacement.

SIEMENS 6ES7151-3AA22-0AB0
SCHNEIDER 140ϵ еĸ
FOXBORO FCP280


Reviews